{"title":"用于识别阿片类药物相关用药过量病例的国际疾病分类算法(ICD-9 和 ICD-10)的灵敏度和特异性:在缺乏黄金标准的情况下使用贝叶斯潜类模型进行估算的系统性综述和实例。","authors":"Fiston Ikwa Ndol Mbutiwi, Ayekoe Patrick Junior Yapo, Serge Esako Toirambe, Erin Rees, Rebecca Plouffe, Hélène Carabin","doi":"10.17269/s41997-024-00915-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aimed to summarize validity estimates of International Classification of Diseases (ICD) codes in identifying opioid overdose (OOD) among patient data from emergency rooms, emergency medical services, inpatient, outpatient, administrative, medical claims, and mortality, and estimate the sensitivity and specificity of the algorithms in the absence of a perfect reference standard.</p><p><strong>Methods: </strong>We systematically reviewed studies published before December 8, 2023, and identified with Medline and Embase. Studies reporting sufficient details to recreate a 2 × 2 table comparing the ICD algorithms to a reference standard in diagnosing OOD-related events were included. We used Bayesian latent class models (BLCM) to estimate the posterior sensitivity and specificity distributions of five ICD-10 algorithms and of the imperfect coroner's report review (CRR) in detecting prescription opioid-related deaths (POD) using one included study.</p><p><strong>Results: </strong>Of a total of 1990 studies reviewed, three were included. The reported sensitivity estimates of ICD algorithms for OOD were low (range from 25.0% to 56.8%) for ICD-9 in diagnosing non-fatal OOD-related events and moderate (72% to 89%) for ICD-10 in diagnosing POD. The last included study used ICD-9 for non-fatal and fatal and ICD-10 for fatal OOD-related events and showed high sensitivity (i.e. above 97%). The specificity estimates of ICD algorithms were good to excellent in the three included studies. The misclassification-adjusted ICD-10 algorithm sensitivity estimates for POD from BLCM were consistently higher than reported sensitivity estimates that assumed CRR was perfect.</p><p><strong>Conclusion: </strong>Evidence on the performance of ICD algorithms in detecting OOD events is scarce, and the absence of bias correction for imperfect tests leads to an underestimation of the sensitivity of ICD code estimates.</p>","PeriodicalId":51407,"journal":{"name":"Canadian Journal of Public Health-Revue Canadienne De Sante Publique","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11535208/pdf/","citationCount":"0","resultStr":"{\"title\":\"Sensitivity and specificity of International Classification of Diseases algorithms (ICD-9 and ICD-10) used to identify opioid-related overdose cases: A systematic review and an example of estimation using Bayesian latent class models in the absence of gold standards.\",\"authors\":\"Fiston Ikwa Ndol Mbutiwi, Ayekoe Patrick Junior Yapo, Serge Esako Toirambe, Erin Rees, Rebecca Plouffe, Hélène Carabin\",\"doi\":\"10.17269/s41997-024-00915-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This study aimed to summarize validity estimates of International Classification of Diseases (ICD) codes in identifying opioid overdose (OOD) among patient data from emergency rooms, emergency medical services, inpatient, outpatient, administrative, medical claims, and mortality, and estimate the sensitivity and specificity of the algorithms in the absence of a perfect reference standard.</p><p><strong>Methods: </strong>We systematically reviewed studies published before December 8, 2023, and identified with Medline and Embase. Studies reporting sufficient details to recreate a 2 × 2 table comparing the ICD algorithms to a reference standard in diagnosing OOD-related events were included. We used Bayesian latent class models (BLCM) to estimate the posterior sensitivity and specificity distributions of five ICD-10 algorithms and of the imperfect coroner's report review (CRR) in detecting prescription opioid-related deaths (POD) using one included study.</p><p><strong>Results: </strong>Of a total of 1990 studies reviewed, three were included. The reported sensitivity estimates of ICD algorithms for OOD were low (range from 25.0% to 56.8%) for ICD-9 in diagnosing non-fatal OOD-related events and moderate (72% to 89%) for ICD-10 in diagnosing POD. The last included study used ICD-9 for non-fatal and fatal and ICD-10 for fatal OOD-related events and showed high sensitivity (i.e. above 97%). The specificity estimates of ICD algorithms were good to excellent in the three included studies. The misclassification-adjusted ICD-10 algorithm sensitivity estimates for POD from BLCM were consistently higher than reported sensitivity estimates that assumed CRR was perfect.</p><p><strong>Conclusion: </strong>Evidence on the performance of ICD algorithms in detecting OOD events is scarce, and the absence of bias correction for imperfect tests leads to an underestimation of the sensitivity of ICD code estimates.</p>\",\"PeriodicalId\":51407,\"journal\":{\"name\":\"Canadian Journal of Public Health-Revue Canadienne De Sante Publique\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11535208/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian Journal of Public Health-Revue Canadienne De Sante Publique\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.17269/s41997-024-00915-4\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Journal of Public Health-Revue Canadienne De Sante Publique","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.17269/s41997-024-00915-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/31 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
Sensitivity and specificity of International Classification of Diseases algorithms (ICD-9 and ICD-10) used to identify opioid-related overdose cases: A systematic review and an example of estimation using Bayesian latent class models in the absence of gold standards.
Objectives: This study aimed to summarize validity estimates of International Classification of Diseases (ICD) codes in identifying opioid overdose (OOD) among patient data from emergency rooms, emergency medical services, inpatient, outpatient, administrative, medical claims, and mortality, and estimate the sensitivity and specificity of the algorithms in the absence of a perfect reference standard.
Methods: We systematically reviewed studies published before December 8, 2023, and identified with Medline and Embase. Studies reporting sufficient details to recreate a 2 × 2 table comparing the ICD algorithms to a reference standard in diagnosing OOD-related events were included. We used Bayesian latent class models (BLCM) to estimate the posterior sensitivity and specificity distributions of five ICD-10 algorithms and of the imperfect coroner's report review (CRR) in detecting prescription opioid-related deaths (POD) using one included study.
Results: Of a total of 1990 studies reviewed, three were included. The reported sensitivity estimates of ICD algorithms for OOD were low (range from 25.0% to 56.8%) for ICD-9 in diagnosing non-fatal OOD-related events and moderate (72% to 89%) for ICD-10 in diagnosing POD. The last included study used ICD-9 for non-fatal and fatal and ICD-10 for fatal OOD-related events and showed high sensitivity (i.e. above 97%). The specificity estimates of ICD algorithms were good to excellent in the three included studies. The misclassification-adjusted ICD-10 algorithm sensitivity estimates for POD from BLCM were consistently higher than reported sensitivity estimates that assumed CRR was perfect.
Conclusion: Evidence on the performance of ICD algorithms in detecting OOD events is scarce, and the absence of bias correction for imperfect tests leads to an underestimation of the sensitivity of ICD code estimates.
期刊介绍:
The Canadian Journal of Public Health is dedicated to fostering excellence in public health research, scholarship, policy and practice. The aim of the Journal is to advance public health research and practice in Canada and around the world, thus contributing to the improvement of the health of populations and the reduction of health inequalities.
CJPH publishes original research and scholarly articles submitted in either English or French that are relevant to population and public health.
CJPH is an independent, peer-reviewed journal owned by the Canadian Public Health Association and published by Springer.
Énoncé de mission
La Revue canadienne de santé publique se consacre à promouvoir l’excellence dans la recherche, les travaux d’érudition, les politiques et les pratiques de santé publique. Son but est de faire progresser la recherche et les pratiques de santé publique au Canada et dans le monde, contribuant ainsi à l’amélioration de la santé des populations et à la réduction des inégalités de santé.
La RCSP publie des articles savants et des travaux inédits, soumis en anglais ou en français, qui sont d’intérêt pour la santé publique et des populations.
La RCSP est une revue indépendante avec comité de lecture, propriété de l’Association canadienne de santé publique et publiée par Springer.