Karolin Voss, Philip Holzbeck, Klaus Pfeilsticker, Ralph Kleinschek, Gerald Wetzel, Blanca Fuentes Andrade, Michael Höpfner, Jörn Ungermann, Björn-Martin Sinnhuber, André Butz
{"title":"用于直接测量平流层溴的新型气球载紫外可见光谱仪","authors":"Karolin Voss, Philip Holzbeck, Klaus Pfeilsticker, Ralph Kleinschek, Gerald Wetzel, Blanca Fuentes Andrade, Michael Höpfner, Jörn Ungermann, Björn-Martin Sinnhuber, André Butz","doi":"10.5194/amt-17-4507-2024","DOIUrl":null,"url":null,"abstract":"Abstract. We report on a novel, medium-weight (∼ 25 kg) optical spectrometer coupled to an automated sun tracker for direct sun observations from azimuth-controlled balloon platforms weighing approximately 12 kg. It is designed to measure a suite of UV–Vis absorbing gases relevant in the context of stratospheric ozone depletion using the differential optical absorption spectroscopy (DOAS) method, i.e. O3, NO2, BrO, OClO, HONO, and IO. Here, we describe the design and major features of the instrument. Further, the instrument's performance during two stratospheric deployments from Esrange near Kiruna (Sweden) on 21 August 2021 and from Timmins (Ontario, Canada) on 23 August 2022 is discussed along with the first results concerning inferred mixing ratios of BrO above balloon float altitude. Using a photochemical correction for the partitioning of stratospheric bromine ([BrO]/[Bry]) obtained by chemical transport simulations, the inferred total stratospheric bromine load [Bry] amounts to (17.5 ± 2.2) ppt, with a purely statistical error amounting to 1.5 ppt in (5.5 ± 1.0)-year old air. The latter is inferred from simultaneous measurements of N2O by the GLORIA (Gimballed Limb Observer for Radiance Imaging of the Atmosphere) mid-IR instrument, resulting in a stratospheric entry of the investigated air mass in early 2017 ± 1 year.","PeriodicalId":8619,"journal":{"name":"Atmospheric Measurement Techniques","volume":"147 1","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel, balloon-borne UV–Vis spectrometer for direct sun measurements of stratospheric bromine\",\"authors\":\"Karolin Voss, Philip Holzbeck, Klaus Pfeilsticker, Ralph Kleinschek, Gerald Wetzel, Blanca Fuentes Andrade, Michael Höpfner, Jörn Ungermann, Björn-Martin Sinnhuber, André Butz\",\"doi\":\"10.5194/amt-17-4507-2024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract. We report on a novel, medium-weight (∼ 25 kg) optical spectrometer coupled to an automated sun tracker for direct sun observations from azimuth-controlled balloon platforms weighing approximately 12 kg. It is designed to measure a suite of UV–Vis absorbing gases relevant in the context of stratospheric ozone depletion using the differential optical absorption spectroscopy (DOAS) method, i.e. O3, NO2, BrO, OClO, HONO, and IO. Here, we describe the design and major features of the instrument. Further, the instrument's performance during two stratospheric deployments from Esrange near Kiruna (Sweden) on 21 August 2021 and from Timmins (Ontario, Canada) on 23 August 2022 is discussed along with the first results concerning inferred mixing ratios of BrO above balloon float altitude. Using a photochemical correction for the partitioning of stratospheric bromine ([BrO]/[Bry]) obtained by chemical transport simulations, the inferred total stratospheric bromine load [Bry] amounts to (17.5 ± 2.2) ppt, with a purely statistical error amounting to 1.5 ppt in (5.5 ± 1.0)-year old air. The latter is inferred from simultaneous measurements of N2O by the GLORIA (Gimballed Limb Observer for Radiance Imaging of the Atmosphere) mid-IR instrument, resulting in a stratospheric entry of the investigated air mass in early 2017 ± 1 year.\",\"PeriodicalId\":8619,\"journal\":{\"name\":\"Atmospheric Measurement Techniques\",\"volume\":\"147 1\",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Atmospheric Measurement Techniques\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.5194/amt-17-4507-2024\",\"RegionNum\":3,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"METEOROLOGY & ATMOSPHERIC SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atmospheric Measurement Techniques","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.5194/amt-17-4507-2024","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"METEOROLOGY & ATMOSPHERIC SCIENCES","Score":null,"Total":0}
A novel, balloon-borne UV–Vis spectrometer for direct sun measurements of stratospheric bromine
Abstract. We report on a novel, medium-weight (∼ 25 kg) optical spectrometer coupled to an automated sun tracker for direct sun observations from azimuth-controlled balloon platforms weighing approximately 12 kg. It is designed to measure a suite of UV–Vis absorbing gases relevant in the context of stratospheric ozone depletion using the differential optical absorption spectroscopy (DOAS) method, i.e. O3, NO2, BrO, OClO, HONO, and IO. Here, we describe the design and major features of the instrument. Further, the instrument's performance during two stratospheric deployments from Esrange near Kiruna (Sweden) on 21 August 2021 and from Timmins (Ontario, Canada) on 23 August 2022 is discussed along with the first results concerning inferred mixing ratios of BrO above balloon float altitude. Using a photochemical correction for the partitioning of stratospheric bromine ([BrO]/[Bry]) obtained by chemical transport simulations, the inferred total stratospheric bromine load [Bry] amounts to (17.5 ± 2.2) ppt, with a purely statistical error amounting to 1.5 ppt in (5.5 ± 1.0)-year old air. The latter is inferred from simultaneous measurements of N2O by the GLORIA (Gimballed Limb Observer for Radiance Imaging of the Atmosphere) mid-IR instrument, resulting in a stratospheric entry of the investigated air mass in early 2017 ± 1 year.
期刊介绍:
Atmospheric Measurement Techniques (AMT) is an international scientific journal dedicated to the publication and discussion of advances in remote sensing, in-situ and laboratory measurement techniques for the constituents and properties of the Earth’s atmosphere.
The main subject areas comprise the development, intercomparison and validation of measurement instruments and techniques of data processing and information retrieval for gases, aerosols, and clouds. The manuscript types considered for peer-reviewed publication are research articles, review articles, and commentaries.