使用天然砂和低纤维含量的可喷涂工程水泥基复合材料的可行性:混合纤维系统、硅灰以及引气和减少收缩外加剂的影响

Gabriel Arce, Mary Sharifi
{"title":"使用天然砂和低纤维含量的可喷涂工程水泥基复合材料的可行性:混合纤维系统、硅灰以及引气和减少收缩外加剂的影响","authors":"Gabriel Arce, Mary Sharifi","doi":"10.1177/03611981241263571","DOIUrl":null,"url":null,"abstract":"Deterioration of corrugated steel culverts (CSCs) is a significant problem for the Virginia Department of Transportation and other U.S. transportation agencies. Spray-on lining using shotcrete engineered cementitious composites (ECCs) is a promising structural repair strategy for deteriorated CSCs. This study evaluates the feasibility of practical sprayable ECCs using natural silica sand and low fiber content, while forgoing the use of commonly utilized calcium sulfoaluminate cement to allow for delivery of the materials via ready-mixed concrete trucks. Aspects of the compositional space evaluated include the effect of a hybrid polyvinyl alcohol/polyethylene fiber system, silica fume (SF), shrinkage reducing admixture (SRA), and air-entraining admixture (AEA) on the properties of the composites. Experimental results suggested that the development of the proposed materials is feasible, because flow characteristics associated with shotcrete ECCs and ECC-like tensile ductility were achieved in the fresh and hardened state, respectively. Notwithstanding, further mixture optimization may be required for satisfactory field performance, which should be assessed through field testing. Generally, the use of the hybrid fiber system tended to improve the strength and ductility of the composites, especially when coupled with the use of SF. Furthermore, SF was effective at mitigating the strength loss associated with the incorporation of AEA and SRA, and meaningfully improved surface resistivity. SF also tended to reduce the mixture’s flow, whereas the contrary occurred with the use of SRA and AEA. SRA contributed to the reduction in drying shrinkage at early ages. However, the effect of SRA in reducing shrinkage was negligible at later ages.","PeriodicalId":517391,"journal":{"name":"Transportation Research Record: Journal of the Transportation Research Board","volume":"39 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Feasibility of Sprayable Engineered Cementitious Composites Using Natural Sand and Low Fiber Content: Effect of Hybrid Fiber System, Silica Fume, and Air-Entraining and Shrinkage-Reducing Admixtures\",\"authors\":\"Gabriel Arce, Mary Sharifi\",\"doi\":\"10.1177/03611981241263571\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Deterioration of corrugated steel culverts (CSCs) is a significant problem for the Virginia Department of Transportation and other U.S. transportation agencies. Spray-on lining using shotcrete engineered cementitious composites (ECCs) is a promising structural repair strategy for deteriorated CSCs. This study evaluates the feasibility of practical sprayable ECCs using natural silica sand and low fiber content, while forgoing the use of commonly utilized calcium sulfoaluminate cement to allow for delivery of the materials via ready-mixed concrete trucks. Aspects of the compositional space evaluated include the effect of a hybrid polyvinyl alcohol/polyethylene fiber system, silica fume (SF), shrinkage reducing admixture (SRA), and air-entraining admixture (AEA) on the properties of the composites. Experimental results suggested that the development of the proposed materials is feasible, because flow characteristics associated with shotcrete ECCs and ECC-like tensile ductility were achieved in the fresh and hardened state, respectively. Notwithstanding, further mixture optimization may be required for satisfactory field performance, which should be assessed through field testing. Generally, the use of the hybrid fiber system tended to improve the strength and ductility of the composites, especially when coupled with the use of SF. Furthermore, SF was effective at mitigating the strength loss associated with the incorporation of AEA and SRA, and meaningfully improved surface resistivity. SF also tended to reduce the mixture’s flow, whereas the contrary occurred with the use of SRA and AEA. SRA contributed to the reduction in drying shrinkage at early ages. However, the effect of SRA in reducing shrinkage was negligible at later ages.\",\"PeriodicalId\":517391,\"journal\":{\"name\":\"Transportation Research Record: Journal of the Transportation Research Board\",\"volume\":\"39 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transportation Research Record: Journal of the Transportation Research Board\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/03611981241263571\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transportation Research Record: Journal of the Transportation Research Board","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/03611981241263571","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

波形钢涵洞(CSC)的老化是弗吉尼亚州运输部和美国其他运输机构面临的一个重大问题。使用喷射混凝土工程水泥基复合材料(ECC)进行喷射衬砌是一种很有前途的修复老化 CSC 结构的策略。本研究评估了使用天然硅砂和低纤维含量的实用可喷射 ECC 的可行性,同时放弃使用常用的硫铝酸钙水泥,以便通过预拌混凝土运输车运送材料。评估的成分空间包括混合聚乙烯醇/聚乙烯纤维系统、硅灰(SF)、减缩外加剂(SRA)和引气外加剂(AEA)对复合材料性能的影响。实验结果表明,由于在新鲜和硬化状态下分别实现了与喷射混凝土 ECC 相关的流动特性和类似 ECC 的拉伸延展性,因此开发所建议的材料是可行的。尽管如此,为了获得令人满意的现场性能,可能还需要进一步优化混合物,这需要通过现场测试来评估。一般来说,使用混合纤维系统往往能提高复合材料的强度和延展性,尤其是在使用 SF 的情况下。此外,SF 还能有效减轻因加入 AEA 和 SRA 而造成的强度损失,并显著提高表面电阻率。SF 还有降低混合物流动性的趋势,而使用 SRA 和 AEA 时则相反。SRA 有助于减少早期龄期的干燥收缩。然而,在较晚的龄期,SRA 在减少收缩方面的作用可以忽略不计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Feasibility of Sprayable Engineered Cementitious Composites Using Natural Sand and Low Fiber Content: Effect of Hybrid Fiber System, Silica Fume, and Air-Entraining and Shrinkage-Reducing Admixtures
Deterioration of corrugated steel culverts (CSCs) is a significant problem for the Virginia Department of Transportation and other U.S. transportation agencies. Spray-on lining using shotcrete engineered cementitious composites (ECCs) is a promising structural repair strategy for deteriorated CSCs. This study evaluates the feasibility of practical sprayable ECCs using natural silica sand and low fiber content, while forgoing the use of commonly utilized calcium sulfoaluminate cement to allow for delivery of the materials via ready-mixed concrete trucks. Aspects of the compositional space evaluated include the effect of a hybrid polyvinyl alcohol/polyethylene fiber system, silica fume (SF), shrinkage reducing admixture (SRA), and air-entraining admixture (AEA) on the properties of the composites. Experimental results suggested that the development of the proposed materials is feasible, because flow characteristics associated with shotcrete ECCs and ECC-like tensile ductility were achieved in the fresh and hardened state, respectively. Notwithstanding, further mixture optimization may be required for satisfactory field performance, which should be assessed through field testing. Generally, the use of the hybrid fiber system tended to improve the strength and ductility of the composites, especially when coupled with the use of SF. Furthermore, SF was effective at mitigating the strength loss associated with the incorporation of AEA and SRA, and meaningfully improved surface resistivity. SF also tended to reduce the mixture’s flow, whereas the contrary occurred with the use of SRA and AEA. SRA contributed to the reduction in drying shrinkage at early ages. However, the effect of SRA in reducing shrinkage was negligible at later ages.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Ordinal Clustering Based Homogeneous Road Segments in Asphalt Pavement Maintenance and Rehabilitation Optimized Decision-Making Exploring the Relationship Between COVID-19 Transmission and Population Mobility over Time CTAFFNet: CNN–Transformer Adaptive Feature Fusion Object Detection Algorithm for Complex Traffic Scenarios Eye Movement Evaluation of Pedestrians' Mobile Phone Usage at Street Crossings Impact of Texting-Induced Distraction on Driving Behavior Based on Field Operation Tests
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1