{"title":"EXPRESS:了解高级衰减全反射校正:低吸收率假设。","authors":"Thomas G Mayerhöfer, Jürgen Popp","doi":"10.1177/00037028241268024","DOIUrl":null,"url":null,"abstract":"<p><p>We present an attenuated total reflection (ATR) correction scheme capable of rectifying ATR spectra while considering the polarization state for arbitrary angles of incidence, provided that this angle exceeds the critical angle for the entire ATR spectrum. Due to its reliance on the weak absorption approximation, it cannot achieve perfect correction of the ATR spectra. However, comprehending its functionality may offer valuable insights into the concept behind the weak absorption approximation. Depending on the specific polarization state of an instrument accessory combination, this correction scheme may outperform the proprietary advanced ATR correction authored by ThermoFisher while being as user-friendly, but in contrast to the latter completely transparent with regard to its functionality.</p>","PeriodicalId":8253,"journal":{"name":"Applied Spectroscopy","volume":" ","pages":"37028241268024"},"PeriodicalIF":2.2000,"publicationDate":"2024-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Understanding Advanced Attenuated Total Reflection Correction: The Low Absorbance Assumption.\",\"authors\":\"Thomas G Mayerhöfer, Jürgen Popp\",\"doi\":\"10.1177/00037028241268024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We present an attenuated total reflection (ATR) correction scheme capable of rectifying ATR spectra while considering the polarization state for arbitrary angles of incidence, provided that this angle exceeds the critical angle for the entire ATR spectrum. Due to its reliance on the weak absorption approximation, it cannot achieve perfect correction of the ATR spectra. However, comprehending its functionality may offer valuable insights into the concept behind the weak absorption approximation. Depending on the specific polarization state of an instrument accessory combination, this correction scheme may outperform the proprietary advanced ATR correction authored by ThermoFisher while being as user-friendly, but in contrast to the latter completely transparent with regard to its functionality.</p>\",\"PeriodicalId\":8253,\"journal\":{\"name\":\"Applied Spectroscopy\",\"volume\":\" \",\"pages\":\"37028241268024\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-08-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Spectroscopy\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1177/00037028241268024\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/00037028241268024","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
Understanding Advanced Attenuated Total Reflection Correction: The Low Absorbance Assumption.
We present an attenuated total reflection (ATR) correction scheme capable of rectifying ATR spectra while considering the polarization state for arbitrary angles of incidence, provided that this angle exceeds the critical angle for the entire ATR spectrum. Due to its reliance on the weak absorption approximation, it cannot achieve perfect correction of the ATR spectra. However, comprehending its functionality may offer valuable insights into the concept behind the weak absorption approximation. Depending on the specific polarization state of an instrument accessory combination, this correction scheme may outperform the proprietary advanced ATR correction authored by ThermoFisher while being as user-friendly, but in contrast to the latter completely transparent with regard to its functionality.
期刊介绍:
Applied Spectroscopy is one of the world''s leading spectroscopy journals, publishing high-quality peer-reviewed articles, both fundamental and applied, covering all aspects of spectroscopy. Established in 1951, the journal is owned by the Society for Applied Spectroscopy and is published monthly. The journal is dedicated to fulfilling the mission of the Society to “…advance and disseminate knowledge and information concerning the art and science of spectroscopy and other allied sciences.”