作为左心室辅助装置植入术预后生物标志物的Galectin-3

IF 3.1 3区 医学 Q2 ENGINEERING, BIOMEDICAL ASAIO Journal Pub Date : 2024-08-02 DOI:10.1097/MAT.0000000000002292
Ryan Hoang, Mary E Acosta, Mark N Belkin, Nabeel F Rasheed, Umar Siddiqi, Jennifer M Cruz, Sydney E Lupo, Corinne R Stonebraker, Sara Kalantari, Jonathan Grinstein
{"title":"作为左心室辅助装置植入术预后生物标志物的Galectin-3","authors":"Ryan Hoang, Mary E Acosta, Mark N Belkin, Nabeel F Rasheed, Umar Siddiqi, Jennifer M Cruz, Sydney E Lupo, Corinne R Stonebraker, Sara Kalantari, Jonathan Grinstein","doi":"10.1097/MAT.0000000000002292","DOIUrl":null,"url":null,"abstract":"<p><p>We assessed the prognostic potential of Galectin-3 in a sample of 159 heart failure patients who received a left ventricular assist device (LVAD) implant from 2012 to 2020. Clinical outcomes included hemodynamic data, right heart failure (RHF), hemocompatibility-related adverse events (HRAEs), and mortality. Galectin-3 was compounded into Michigan-RVF and EUROMACS-RHF risk scores and compared to the noncompounded risk scores. Right heart failure was significantly correlated with Galectin (p = 0.004) on a continuous spectrum. Inotrope duration was significantly correlated to Galectin-3 (interquartile range [IQR]: 7.58-8.65, p < 0.001) along with INTERMACS score (IQR: 2.14-1.90, p < 0.001). Intensive care unit length of stay (median 8 days, p = 0.02), blood urea nitrogen (p < 0.001), creatinine (p < 0.001), and pulmonary artery pulsatility index (p = 0.05) were also significantly correlated with Galectin-3. In our c-statistic analysis, the predictive value for RHF improved when Galectin-3 was included for both the Michigan-RVF (0.80-0.86) and EUROMACS-RHF (0.77-0.82) risk scores. When elevated over a binary cutoff of 18.2 ng/ml, Galectin-3 significantly correlated with HRAEs (p = 0.014) and mortality (p = 0.031). Galectin-3 shows great promise as a predictive biomarker in patients implanted with durable LVADs. In addition to significant correlation with key clinical outcomes, Galectin-3 enhanced the Michigan-RVF and EUROMACS-RHF risk scores in predicting progression to RHF.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Galectin-3 as a Prognostic Biomarker of Left Ventricular Assist Device Implantation Outcomes.\",\"authors\":\"Ryan Hoang, Mary E Acosta, Mark N Belkin, Nabeel F Rasheed, Umar Siddiqi, Jennifer M Cruz, Sydney E Lupo, Corinne R Stonebraker, Sara Kalantari, Jonathan Grinstein\",\"doi\":\"10.1097/MAT.0000000000002292\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We assessed the prognostic potential of Galectin-3 in a sample of 159 heart failure patients who received a left ventricular assist device (LVAD) implant from 2012 to 2020. Clinical outcomes included hemodynamic data, right heart failure (RHF), hemocompatibility-related adverse events (HRAEs), and mortality. Galectin-3 was compounded into Michigan-RVF and EUROMACS-RHF risk scores and compared to the noncompounded risk scores. Right heart failure was significantly correlated with Galectin (p = 0.004) on a continuous spectrum. Inotrope duration was significantly correlated to Galectin-3 (interquartile range [IQR]: 7.58-8.65, p < 0.001) along with INTERMACS score (IQR: 2.14-1.90, p < 0.001). Intensive care unit length of stay (median 8 days, p = 0.02), blood urea nitrogen (p < 0.001), creatinine (p < 0.001), and pulmonary artery pulsatility index (p = 0.05) were also significantly correlated with Galectin-3. In our c-statistic analysis, the predictive value for RHF improved when Galectin-3 was included for both the Michigan-RVF (0.80-0.86) and EUROMACS-RHF (0.77-0.82) risk scores. When elevated over a binary cutoff of 18.2 ng/ml, Galectin-3 significantly correlated with HRAEs (p = 0.014) and mortality (p = 0.031). Galectin-3 shows great promise as a predictive biomarker in patients implanted with durable LVADs. In addition to significant correlation with key clinical outcomes, Galectin-3 enhanced the Michigan-RVF and EUROMACS-RHF risk scores in predicting progression to RHF.</p>\",\"PeriodicalId\":8844,\"journal\":{\"name\":\"ASAIO Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-08-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ASAIO Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1097/MAT.0000000000002292\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002292","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

我们对 2012 年至 2020 年期间接受左心室辅助装置(LVAD)植入的 159 例心衰患者样本中 Galectin-3 的预后潜力进行了评估。临床结果包括血液动力学数据、右心衰(RHF)、血液相容性相关不良事件(HRAE)和死亡率。Galectin-3被复合到密歇根-RVF和EUROMACS-RHF风险评分中,并与非复合风险评分进行比较。在连续谱上,右心衰竭与 Galectin 显著相关(p = 0.004)。肌注持续时间与 Galectin-3(四分位数间距 [IQR]:7.58-8.65,p < 0.001)和 INTERMACS 评分(四分位数间距 [IQR]:2.14-1.90,p < 0.001)明显相关。重症监护室的住院时间(中位 8 天,p = 0.02)、血尿素氮(p < 0.001)、肌酐(p < 0.001)和肺动脉搏动指数(p = 0.05)也与 Galectin-3 显著相关。在我们的 c 统计学分析中,当密歇根-RVF(0.80-0.86)和 EUROMACS-RHF (0.77-0.82)风险评分中包含 Galectin-3 时,RHF 的预测值有所提高。当 Galectin-3 升高超过 18.2 ng/ml 的二元临界值时,它与 HRAEs(p = 0.014)和死亡率(p = 0.031)显著相关。Galectin-3 很有希望成为植入耐久性 LVAD 患者的预测性生物标志物。除了与主要临床结果有明显相关性外,Galectin-3 还增强了密歇根-RVF 和 EUROMACS-RHF 风险评分在预测 RHF 进展方面的作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Galectin-3 as a Prognostic Biomarker of Left Ventricular Assist Device Implantation Outcomes.

We assessed the prognostic potential of Galectin-3 in a sample of 159 heart failure patients who received a left ventricular assist device (LVAD) implant from 2012 to 2020. Clinical outcomes included hemodynamic data, right heart failure (RHF), hemocompatibility-related adverse events (HRAEs), and mortality. Galectin-3 was compounded into Michigan-RVF and EUROMACS-RHF risk scores and compared to the noncompounded risk scores. Right heart failure was significantly correlated with Galectin (p = 0.004) on a continuous spectrum. Inotrope duration was significantly correlated to Galectin-3 (interquartile range [IQR]: 7.58-8.65, p < 0.001) along with INTERMACS score (IQR: 2.14-1.90, p < 0.001). Intensive care unit length of stay (median 8 days, p = 0.02), blood urea nitrogen (p < 0.001), creatinine (p < 0.001), and pulmonary artery pulsatility index (p = 0.05) were also significantly correlated with Galectin-3. In our c-statistic analysis, the predictive value for RHF improved when Galectin-3 was included for both the Michigan-RVF (0.80-0.86) and EUROMACS-RHF (0.77-0.82) risk scores. When elevated over a binary cutoff of 18.2 ng/ml, Galectin-3 significantly correlated with HRAEs (p = 0.014) and mortality (p = 0.031). Galectin-3 shows great promise as a predictive biomarker in patients implanted with durable LVADs. In addition to significant correlation with key clinical outcomes, Galectin-3 enhanced the Michigan-RVF and EUROMACS-RHF risk scores in predicting progression to RHF.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ASAIO Journal
ASAIO Journal 医学-工程:生物医学
CiteScore
6.60
自引率
7.10%
发文量
651
审稿时长
4-8 weeks
期刊介绍: ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world. The official publication of the American Society for Artificial Internal Organs.
期刊最新文献
Prosthetic Valve Fate in Patients With Continuous-Flow Left Ventricular Assist Devices. Heart Transplantation Outcomes in Patients With Hypertrophic Cardiomyopathy in the Era of Mechanical Circulatory Support. Predictive Accuracy of HeartMate 3 Risk Score After the Heart Transplant Allocation Change. Reply Letter to Editor to Daniel Schneditz. Impella as Bridge to Durable Left Ventricular Assist Device in Acute Myocardial Infarction Cardiogenic Shock Patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1