闪蒸/ORC 混合发电厂热交换设备的重量和尺寸特征:WHR 热电联产厂的应用案例

Andriy Redko, Serhii Pavlovskyi, Oleksandr Redko, Adam Ujma, Vadym Zadiranov
{"title":"闪蒸/ORC 混合发电厂热交换设备的重量和尺寸特征:WHR 热电联产厂的应用案例","authors":"Andriy Redko, Serhii Pavlovskyi, Oleksandr Redko, Adam Ujma, Vadym Zadiranov","doi":"10.1088/1755-1315/1376/1/012032","DOIUrl":null,"url":null,"abstract":"Calculations of the characteristics concerning the heat exchange equipment of the Flash/ORC power plant for the usage in waste heat recovery (WHR) cogeneration plants are presented. The use of hybrid power plants with water steam and organic working fluids, on the one hand, leads to an increase in the mass of the heat exchange equipment, and on the other hand, it ensures the generation of electrical energy and heat at high temperatures of the heat source, when the use of high-temperature working fluids is limited their thermal stability (for example, the thermal stability of silaxanes is about 300 ºC). Calculations are performed for a heat source with temperatures of 250ºC and 350 ºC. The generated electrical power of the power plant at a heat source temperature of 350ºC is 460 kW. The generated thermal power by capacitors is 1755.3 kW. The mass of the capacitors of the second and third circuits is 5000 kg and 14500 kg, respectively. It is shown that when the temperature of the heat source decreases to 250ºC with a double-circuit design, the mass of the heat exchange equipment decreases. Thus, the mass of the condenser is 12700 kg, and the generated thermal power is 1430.2 kW. The values of the heat exchange surface area of a direct-flow steam generator with flue gases, and an intermediate steam generator between the stages of the thermal circuit of a regenerative heat exchanger, as well as a water-cooled condenser are given. When the condenser is cooled by atmospheric air, the surface area of the condenser increases significantly. A characteristic feature of organic working fluids is the low efficiency of heat exchange in heat exchangers, especially at low temperatures. The heat transfer coefficient in heat exchangers with organic working fluids is about 1500-2800 W/(m2•K), which causes an increase in the heat exchange surface area. In this case, it is necessary to reduce the diameters of pipes in the heat exchangers of the steam generator, to use the pipes with internal ribs, and coil pipes in order to reduce the pipe length. The use of steam generators with coil steam-generating channels, characterized by a higher heat exchange intensity, is promising. The selection of the optimal structure and parameters of the ORC installation is carried out taking into account the mutual influence of steam turbine units on the efficiency of working processes in general.","PeriodicalId":14556,"journal":{"name":"IOP Conference Series: Earth and Environmental Science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Weight and size characteristics of heat exchange equipment of hybrid Flash/ORC power plants: case of application in WHR cogeneration plants\",\"authors\":\"Andriy Redko, Serhii Pavlovskyi, Oleksandr Redko, Adam Ujma, Vadym Zadiranov\",\"doi\":\"10.1088/1755-1315/1376/1/012032\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Calculations of the characteristics concerning the heat exchange equipment of the Flash/ORC power plant for the usage in waste heat recovery (WHR) cogeneration plants are presented. The use of hybrid power plants with water steam and organic working fluids, on the one hand, leads to an increase in the mass of the heat exchange equipment, and on the other hand, it ensures the generation of electrical energy and heat at high temperatures of the heat source, when the use of high-temperature working fluids is limited their thermal stability (for example, the thermal stability of silaxanes is about 300 ºC). Calculations are performed for a heat source with temperatures of 250ºC and 350 ºC. The generated electrical power of the power plant at a heat source temperature of 350ºC is 460 kW. The generated thermal power by capacitors is 1755.3 kW. The mass of the capacitors of the second and third circuits is 5000 kg and 14500 kg, respectively. It is shown that when the temperature of the heat source decreases to 250ºC with a double-circuit design, the mass of the heat exchange equipment decreases. Thus, the mass of the condenser is 12700 kg, and the generated thermal power is 1430.2 kW. The values of the heat exchange surface area of a direct-flow steam generator with flue gases, and an intermediate steam generator between the stages of the thermal circuit of a regenerative heat exchanger, as well as a water-cooled condenser are given. When the condenser is cooled by atmospheric air, the surface area of the condenser increases significantly. A characteristic feature of organic working fluids is the low efficiency of heat exchange in heat exchangers, especially at low temperatures. The heat transfer coefficient in heat exchangers with organic working fluids is about 1500-2800 W/(m2•K), which causes an increase in the heat exchange surface area. In this case, it is necessary to reduce the diameters of pipes in the heat exchangers of the steam generator, to use the pipes with internal ribs, and coil pipes in order to reduce the pipe length. The use of steam generators with coil steam-generating channels, characterized by a higher heat exchange intensity, is promising. The selection of the optimal structure and parameters of the ORC installation is carried out taking into account the mutual influence of steam turbine units on the efficiency of working processes in general.\",\"PeriodicalId\":14556,\"journal\":{\"name\":\"IOP Conference Series: Earth and Environmental Science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IOP Conference Series: Earth and Environmental Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/1755-1315/1376/1/012032\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IOP Conference Series: Earth and Environmental Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1755-1315/1376/1/012032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了闪蒸/ORC 发电厂热交换设备在废热回收(WHR)热电联产设备中使用的相关特性计算。使用水蒸汽和有机工作流体的混合动力设备一方面会导致热交换设备的质量增加,另一方面,当使用高温工作流体的热稳定性受到限制时(例如,硅烷的热稳定性约为 300 ºC),它能确保在热源的高温下产生电能和热量。对温度为 250 ºC 和 350 ºC 的热源进行了计算。热源温度为 350ºC 时,发电厂的发电功率为 460 千瓦。电容器产生的热功率为 1755.3 千瓦。第二和第三回路电容器的质量分别为 5000 千克和 14500 千克。双回路设计表明,当热源温度降低到 250 摄氏度时,热交换设备的质量会减少。因此,冷凝器的质量为 12700 千克,产生的热功率为 1430.2 千瓦。文中给出了烟气直流蒸汽发生器、蓄热式热交换器热回路各级之间的中间蒸汽发生器以及水冷式冷凝器的热交换表面积值。当冷凝器由大气空气冷却时,冷凝器的表面积会显著增加。有机工作流体的一个特点是热交换器的热交换效率较低,尤其是在低温条件下。使用有机工作流体的热交换器的传热系数约为 1500-2800 W/(m2-K),这导致热交换表面积增大。在这种情况下,有必要减小蒸汽发生器热交换器的管道直径,使用带内肋的管道和盘管,以减少管道长度。使用具有较高热交换强度的盘管蒸汽发生器很有前途。在选择 ORC 设备的最佳结构和参数时,要考虑到蒸汽轮机组对整个工作流程效率的相互影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Weight and size characteristics of heat exchange equipment of hybrid Flash/ORC power plants: case of application in WHR cogeneration plants
Calculations of the characteristics concerning the heat exchange equipment of the Flash/ORC power plant for the usage in waste heat recovery (WHR) cogeneration plants are presented. The use of hybrid power plants with water steam and organic working fluids, on the one hand, leads to an increase in the mass of the heat exchange equipment, and on the other hand, it ensures the generation of electrical energy and heat at high temperatures of the heat source, when the use of high-temperature working fluids is limited their thermal stability (for example, the thermal stability of silaxanes is about 300 ºC). Calculations are performed for a heat source with temperatures of 250ºC and 350 ºC. The generated electrical power of the power plant at a heat source temperature of 350ºC is 460 kW. The generated thermal power by capacitors is 1755.3 kW. The mass of the capacitors of the second and third circuits is 5000 kg and 14500 kg, respectively. It is shown that when the temperature of the heat source decreases to 250ºC with a double-circuit design, the mass of the heat exchange equipment decreases. Thus, the mass of the condenser is 12700 kg, and the generated thermal power is 1430.2 kW. The values of the heat exchange surface area of a direct-flow steam generator with flue gases, and an intermediate steam generator between the stages of the thermal circuit of a regenerative heat exchanger, as well as a water-cooled condenser are given. When the condenser is cooled by atmospheric air, the surface area of the condenser increases significantly. A characteristic feature of organic working fluids is the low efficiency of heat exchange in heat exchangers, especially at low temperatures. The heat transfer coefficient in heat exchangers with organic working fluids is about 1500-2800 W/(m2•K), which causes an increase in the heat exchange surface area. In this case, it is necessary to reduce the diameters of pipes in the heat exchangers of the steam generator, to use the pipes with internal ribs, and coil pipes in order to reduce the pipe length. The use of steam generators with coil steam-generating channels, characterized by a higher heat exchange intensity, is promising. The selection of the optimal structure and parameters of the ORC installation is carried out taking into account the mutual influence of steam turbine units on the efficiency of working processes in general.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.00
自引率
0.00%
发文量
0
期刊最新文献
Peer Review Statement Response Surface Methodological Approach for the Adsorptive Removal of Geosmin and 2-Methylisoborneol on Sodium Hydroxide-Treated Powdered Activated Carbon Torrefaction performance of Macadamia husk under a flue gas atmosphere for solid biofuel applications Assessing the Techno-Economics of Solar-Assisted Absorption Air Conditioning in a University Building in Jordan Wyoming's produced water: Analysis and green hydrogen potential
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1