马血浆中重组人促红细胞生成素的强化分析 - 改进工作流程的实施。

IF 2.6 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS Drug Testing and Analysis Pub Date : 2024-08-04 DOI:10.1002/dta.3785
Stacey Richards, David Palmer, Adam Cawley, Martin Wainscott, John Keledjian
{"title":"马血浆中重组人促红细胞生成素的强化分析 - 改进工作流程的实施。","authors":"Stacey Richards, David Palmer, Adam Cawley, Martin Wainscott, John Keledjian","doi":"10.1002/dta.3785","DOIUrl":null,"url":null,"abstract":"<p><p>An improved screening workflow and a robust capillary flow LC-MS confirmatory method for the detection of recombinant human erythropoietin (rHuEPO) has been implemented to increase the sensitivity of rHuEPO detection and to reduce the number of suspect samples committed to confirmatory testing. The influence of repeated dosing of epoetin-β on the detection window of rHuEPO in equine plasma was assessed using the optimised method. Samples were initially assessed using an economical R&D Human EPO Duo-Set ELISA Development System. Samples indicating a result greater than the batch baseline were analysed using the complementary R&D Human EPO Quantikine IVD ELISA kit. All samples recording an abnormal screening result were subjected to confirmatory analysis. Confirmation of rHuEPO in plasma (≥2.5 ml) in the range of 4-13 mIU/ml (n = 6) was achieved using immunoaffinity enrichment, tryptic digestion, and capillary flow LC-MS/MS. Four horses were administered a single dose of epoetin-β (10,000 IU) via the subcutaneous and intravenous routes, on two occasions, seven days apart. The excretion profile was rapid with epoetin-β detection times of 48 to 72 h following each administration, with no appreciable difference observed between the two routes of administration. This workflow has been shown as an effective anti-doping strategy related to rHuEPO misuse and supports the use of out-of-competition testing of horses in the 2 to 3-day period prior to race-day.</p>","PeriodicalId":160,"journal":{"name":"Drug Testing and Analysis","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-08-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhanced analysis of equine plasma for the presence of recombinant human erythropoietin - Implementation of an improved workflow.\",\"authors\":\"Stacey Richards, David Palmer, Adam Cawley, Martin Wainscott, John Keledjian\",\"doi\":\"10.1002/dta.3785\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An improved screening workflow and a robust capillary flow LC-MS confirmatory method for the detection of recombinant human erythropoietin (rHuEPO) has been implemented to increase the sensitivity of rHuEPO detection and to reduce the number of suspect samples committed to confirmatory testing. The influence of repeated dosing of epoetin-β on the detection window of rHuEPO in equine plasma was assessed using the optimised method. Samples were initially assessed using an economical R&D Human EPO Duo-Set ELISA Development System. Samples indicating a result greater than the batch baseline were analysed using the complementary R&D Human EPO Quantikine IVD ELISA kit. All samples recording an abnormal screening result were subjected to confirmatory analysis. Confirmation of rHuEPO in plasma (≥2.5 ml) in the range of 4-13 mIU/ml (n = 6) was achieved using immunoaffinity enrichment, tryptic digestion, and capillary flow LC-MS/MS. Four horses were administered a single dose of epoetin-β (10,000 IU) via the subcutaneous and intravenous routes, on two occasions, seven days apart. The excretion profile was rapid with epoetin-β detection times of 48 to 72 h following each administration, with no appreciable difference observed between the two routes of administration. This workflow has been shown as an effective anti-doping strategy related to rHuEPO misuse and supports the use of out-of-competition testing of horses in the 2 to 3-day period prior to race-day.</p>\",\"PeriodicalId\":160,\"journal\":{\"name\":\"Drug Testing and Analysis\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-08-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Drug Testing and Analysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/dta.3785\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Testing and Analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/dta.3785","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

为了提高重组人促红细胞生成素(rHuEPO)的检测灵敏度并减少需要进行确证检测的可疑样品数量,我们采用了改进的筛查工作流程和稳健的毛细管流 LC-MS 确证方法。使用优化方法评估了重复服用环乙素-β对马血浆中 rHuEPO 检测窗口的影响。使用经济型 R&D 人类 EPO Duo-Set ELISA 检测系统对样品进行初步评估。对结果高于批次基线的样本,则使用配套的 R&D 人类 EPO 定量 IVD ELISA 试剂盒进行分析。所有筛查结果异常的样本都要进行确证分析。使用免疫亲和富集、胰蛋白酶消化和毛细管流式 LC-MS/MS,确认血浆(≥2.5 毫升)中的 rHuEPO(4-13 mIU/ml,n = 6)。四匹马通过皮下注射和静脉注射两种途径服用了单剂量的 epoetin-β(10,000 IU),每次间隔七天。每次给药后,epoetin-β 的排泄速度很快,检测时间为 48 至 72 小时,两种给药途径之间没有明显差异。该工作流程已被证明是一种有效的反兴奋剂策略,可防止 rHuEPO 的滥用,并支持在比赛日之前的 2 到 3 天内对马匹进行赛外检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Enhanced analysis of equine plasma for the presence of recombinant human erythropoietin - Implementation of an improved workflow.

An improved screening workflow and a robust capillary flow LC-MS confirmatory method for the detection of recombinant human erythropoietin (rHuEPO) has been implemented to increase the sensitivity of rHuEPO detection and to reduce the number of suspect samples committed to confirmatory testing. The influence of repeated dosing of epoetin-β on the detection window of rHuEPO in equine plasma was assessed using the optimised method. Samples were initially assessed using an economical R&D Human EPO Duo-Set ELISA Development System. Samples indicating a result greater than the batch baseline were analysed using the complementary R&D Human EPO Quantikine IVD ELISA kit. All samples recording an abnormal screening result were subjected to confirmatory analysis. Confirmation of rHuEPO in plasma (≥2.5 ml) in the range of 4-13 mIU/ml (n = 6) was achieved using immunoaffinity enrichment, tryptic digestion, and capillary flow LC-MS/MS. Four horses were administered a single dose of epoetin-β (10,000 IU) via the subcutaneous and intravenous routes, on two occasions, seven days apart. The excretion profile was rapid with epoetin-β detection times of 48 to 72 h following each administration, with no appreciable difference observed between the two routes of administration. This workflow has been shown as an effective anti-doping strategy related to rHuEPO misuse and supports the use of out-of-competition testing of horses in the 2 to 3-day period prior to race-day.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Drug Testing and Analysis
Drug Testing and Analysis BIOCHEMICAL RESEARCH METHODS-CHEMISTRY, ANALYTICAL
CiteScore
5.90
自引率
24.10%
发文量
191
审稿时长
2.3 months
期刊介绍: As the incidence of drugs escalates in 21st century living, their detection and analysis have become increasingly important. Sport, the workplace, crime investigation, homeland security, the pharmaceutical industry and the environment are just some of the high profile arenas in which analytical testing has provided an important investigative tool for uncovering the presence of extraneous substances. In addition to the usual publishing fare of primary research articles, case reports and letters, Drug Testing and Analysis offers a unique combination of; ‘How to’ material such as ‘Tutorials’ and ‘Reviews’, Speculative pieces (‘Commentaries’ and ‘Perspectives'', providing a broader scientific and social context to the aspects of analytical testing), ‘Annual banned substance reviews’ (delivering a critical evaluation of the methods used in the characterization of established and newly outlawed compounds). Rather than focus on the application of a single technique, Drug Testing and Analysis employs a unique multidisciplinary approach to the field of controversial compound determination. Papers discussing chromatography, mass spectrometry, immunological approaches, 1D/2D gel electrophoresis, to name just a few select methods, are welcomed where their application is related to any of the six key topics listed below.
期刊最新文献
Determination of Hormonal Growth Promotants in Beef Using Liquid Chromatography-Tandem Mass Spectrometry. Detecting EPO in Microvolumetric Capillary Serum Shipped at Ambient Temperature for Antidoping Testing. Investigation Into the Equine Metabolism of Phosphodiesterase-4 Inhibitor Roflumilast for Potential Doping Control. UHPLC-QTOFMS Urine Drug Screening With Dilute-and-Shoot Sample Preparation and Vacuum-Insulated Probe-Heated Electrospray Ionization. Cover Picture
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1