{"title":"INFINITY-SWEDEHEART 的原理和设计:一项基于登记的随机临床试验,比较了西罗莫司洗脱的 DynamX 生物适配器和佐他罗莫司洗脱的 Resolute Onyx 支架的临床疗效。","authors":"","doi":"10.1016/j.ahj.2024.07.016","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Modern drug-eluting stents have seen significant improvements, yet still create a rigid cage within the coronary artery. There is a 2% to 4% annual incidence of target lesion failure (TLF) beyond 1 year, and half of the patients experience angina after 5 years. The DynamX bioadaptor is a sirolimus-eluting, thin (71 µm) cobalt-chromium platform with helical strands that unlock and separate after in vivo degradation of the bioresorbable polymer coating. This allows the vessel to return to normal physiological function and motion, along with compensatory adaptive remodeling, which may reduce the need for reintervention and alleviate angina following percutaneous coronary intervention (PCI).</p></div><div><h3>Methods</h3><p>The INFINITY-SWEDEHEART trial is a single-blind, registry-based randomized clinical trial (R-RCT) to evaluate the safety and effectiveness of the DynamX bioadaptor compared to the Resolute Onyx stent in the treatment of patients with ischemic heart disease with de novo native coronary artery lesions. The R-RCT framework allows for recruitment, randomization, and pragmatic data collection of baseline demographics, medications, and clinical outcomes using existing national clinical registries integrated with the trial database. The primary objective is to demonstrate noninferiority in terms of freedom from TLF (cardiovascular death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization) at 1 year. Powered secondary endpoints will be tested sequentially for superiority from 6 months to the end of follow-up (5 years) for the following: 1) TLF in all subjects, 2) target vessel failure in all subjects, and 3) TLF in subjects with acute coronary syndrome (ACS). Subsequent superiority testing will be performed at a time determined depending on the number of events, ensuring sufficient statistical power. Change in angina-related symptoms, function and quality of life will be assessed using the Seattle Angina Questionnaire-short version. Predefined sub-groups will be analyzed. In total, 2400 patients have been randomized at 20 sites in Sweden. Available baseline characteristic reveal relatively old age (68 years) and a large proportion of ACS patients including 25% STEMI and 37% NSTEMI patients.</p></div><div><h3>Summary</h3><p>The INFINITY-SWEDEHEART study is designed to evaluate the long-term safety and efficacy of the DynamX bioadaptor compared to the Resolute Onyx stent in a general PCI patient population.</p></div>","PeriodicalId":7868,"journal":{"name":"American heart journal","volume":null,"pages":null},"PeriodicalIF":3.7000,"publicationDate":"2024-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0002870324001820/pdfft?md5=6b5e99d55ecc656d9e5d5489f23f47c1&pid=1-s2.0-S0002870324001820-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Rationale and design of INFINITY-SWEDEHEART: A registry-based randomized clinical trial comparing clinical outcomes of the sirolimus-eluting DynamX bioadaptor to the zotarolimus-eluting Resolute Onyx stent\",\"authors\":\"\",\"doi\":\"10.1016/j.ahj.2024.07.016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Modern drug-eluting stents have seen significant improvements, yet still create a rigid cage within the coronary artery. There is a 2% to 4% annual incidence of target lesion failure (TLF) beyond 1 year, and half of the patients experience angina after 5 years. The DynamX bioadaptor is a sirolimus-eluting, thin (71 µm) cobalt-chromium platform with helical strands that unlock and separate after in vivo degradation of the bioresorbable polymer coating. This allows the vessel to return to normal physiological function and motion, along with compensatory adaptive remodeling, which may reduce the need for reintervention and alleviate angina following percutaneous coronary intervention (PCI).</p></div><div><h3>Methods</h3><p>The INFINITY-SWEDEHEART trial is a single-blind, registry-based randomized clinical trial (R-RCT) to evaluate the safety and effectiveness of the DynamX bioadaptor compared to the Resolute Onyx stent in the treatment of patients with ischemic heart disease with de novo native coronary artery lesions. The R-RCT framework allows for recruitment, randomization, and pragmatic data collection of baseline demographics, medications, and clinical outcomes using existing national clinical registries integrated with the trial database. The primary objective is to demonstrate noninferiority in terms of freedom from TLF (cardiovascular death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization) at 1 year. Powered secondary endpoints will be tested sequentially for superiority from 6 months to the end of follow-up (5 years) for the following: 1) TLF in all subjects, 2) target vessel failure in all subjects, and 3) TLF in subjects with acute coronary syndrome (ACS). Subsequent superiority testing will be performed at a time determined depending on the number of events, ensuring sufficient statistical power. Change in angina-related symptoms, function and quality of life will be assessed using the Seattle Angina Questionnaire-short version. Predefined sub-groups will be analyzed. In total, 2400 patients have been randomized at 20 sites in Sweden. Available baseline characteristic reveal relatively old age (68 years) and a large proportion of ACS patients including 25% STEMI and 37% NSTEMI patients.</p></div><div><h3>Summary</h3><p>The INFINITY-SWEDEHEART study is designed to evaluate the long-term safety and efficacy of the DynamX bioadaptor compared to the Resolute Onyx stent in a general PCI patient population.</p></div>\",\"PeriodicalId\":7868,\"journal\":{\"name\":\"American heart journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2024-08-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0002870324001820/pdfft?md5=6b5e99d55ecc656d9e5d5489f23f47c1&pid=1-s2.0-S0002870324001820-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American heart journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0002870324001820\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American heart journal","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0002870324001820","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Rationale and design of INFINITY-SWEDEHEART: A registry-based randomized clinical trial comparing clinical outcomes of the sirolimus-eluting DynamX bioadaptor to the zotarolimus-eluting Resolute Onyx stent
Background
Modern drug-eluting stents have seen significant improvements, yet still create a rigid cage within the coronary artery. There is a 2% to 4% annual incidence of target lesion failure (TLF) beyond 1 year, and half of the patients experience angina after 5 years. The DynamX bioadaptor is a sirolimus-eluting, thin (71 µm) cobalt-chromium platform with helical strands that unlock and separate after in vivo degradation of the bioresorbable polymer coating. This allows the vessel to return to normal physiological function and motion, along with compensatory adaptive remodeling, which may reduce the need for reintervention and alleviate angina following percutaneous coronary intervention (PCI).
Methods
The INFINITY-SWEDEHEART trial is a single-blind, registry-based randomized clinical trial (R-RCT) to evaluate the safety and effectiveness of the DynamX bioadaptor compared to the Resolute Onyx stent in the treatment of patients with ischemic heart disease with de novo native coronary artery lesions. The R-RCT framework allows for recruitment, randomization, and pragmatic data collection of baseline demographics, medications, and clinical outcomes using existing national clinical registries integrated with the trial database. The primary objective is to demonstrate noninferiority in terms of freedom from TLF (cardiovascular death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization) at 1 year. Powered secondary endpoints will be tested sequentially for superiority from 6 months to the end of follow-up (5 years) for the following: 1) TLF in all subjects, 2) target vessel failure in all subjects, and 3) TLF in subjects with acute coronary syndrome (ACS). Subsequent superiority testing will be performed at a time determined depending on the number of events, ensuring sufficient statistical power. Change in angina-related symptoms, function and quality of life will be assessed using the Seattle Angina Questionnaire-short version. Predefined sub-groups will be analyzed. In total, 2400 patients have been randomized at 20 sites in Sweden. Available baseline characteristic reveal relatively old age (68 years) and a large proportion of ACS patients including 25% STEMI and 37% NSTEMI patients.
Summary
The INFINITY-SWEDEHEART study is designed to evaluate the long-term safety and efficacy of the DynamX bioadaptor compared to the Resolute Onyx stent in a general PCI patient population.
期刊介绍:
The American Heart Journal will consider for publication suitable articles on topics pertaining to the broad discipline of cardiovascular disease. Our goal is to provide the reader primary investigation, scholarly review, and opinion concerning the practice of cardiovascular medicine. We especially encourage submission of 3 types of reports that are not frequently seen in cardiovascular journals: negative clinical studies, reports on study designs, and studies involving the organization of medical care. The Journal does not accept individual case reports or original articles involving bench laboratory or animal research.