{"title":"酮体监测在糖尿病护理中的创新和应用。","authors":"Naoki Sakane","doi":"10.1007/s13340-024-00735-4","DOIUrl":null,"url":null,"abstract":"<p><p>Ketone bodies, comprising β-hydroxybutyric acid (BHB), acetoacetate (AcAc), and acetone, play a vital role as essential energy substrates. In individuals with diabetes, ketone bodies can be elevated under various conditions, including diabetic ketoacidosis, use of sodium-glucose transporter type 2 (SGLT2) inhibitors, and extreme carbohydrate restriction. There are three methods for measuring ketone bodies. Urine ketone analysis (AcAc) is a standard clinical test, whereas blood ketone testing (BHB+AcAc) is valuable in identifying or resolving diabetic ketoacidosis. Recently, technology for measuring breath acetone has been introduced, which provides an easy means of monitoring ketogenic diets in obese individuals. The basic breath alcohol detector also reacts with breath acetone. Therefore, it is important for professional drivers taking SGLT2 inhibitors to be cautious as workplace breath alcohol detectors may show false-positive results. Conversely, if a positive result is obtained, a detailed examination of ketosis is necessary. This review provides an overview of ketone body measurements in individuals with diabetes.</p>","PeriodicalId":11340,"journal":{"name":"Diabetology International","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11291811/pdf/","citationCount":"0","resultStr":"{\"title\":\"Innovations and applications of ketone body monitoring in diabetes care.\",\"authors\":\"Naoki Sakane\",\"doi\":\"10.1007/s13340-024-00735-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Ketone bodies, comprising β-hydroxybutyric acid (BHB), acetoacetate (AcAc), and acetone, play a vital role as essential energy substrates. In individuals with diabetes, ketone bodies can be elevated under various conditions, including diabetic ketoacidosis, use of sodium-glucose transporter type 2 (SGLT2) inhibitors, and extreme carbohydrate restriction. There are three methods for measuring ketone bodies. Urine ketone analysis (AcAc) is a standard clinical test, whereas blood ketone testing (BHB+AcAc) is valuable in identifying or resolving diabetic ketoacidosis. Recently, technology for measuring breath acetone has been introduced, which provides an easy means of monitoring ketogenic diets in obese individuals. The basic breath alcohol detector also reacts with breath acetone. Therefore, it is important for professional drivers taking SGLT2 inhibitors to be cautious as workplace breath alcohol detectors may show false-positive results. Conversely, if a positive result is obtained, a detailed examination of ketosis is necessary. This review provides an overview of ketone body measurements in individuals with diabetes.</p>\",\"PeriodicalId\":11340,\"journal\":{\"name\":\"Diabetology International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-05-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11291811/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diabetology International\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s13340-024-00735-4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetology International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s13340-024-00735-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
Innovations and applications of ketone body monitoring in diabetes care.
Ketone bodies, comprising β-hydroxybutyric acid (BHB), acetoacetate (AcAc), and acetone, play a vital role as essential energy substrates. In individuals with diabetes, ketone bodies can be elevated under various conditions, including diabetic ketoacidosis, use of sodium-glucose transporter type 2 (SGLT2) inhibitors, and extreme carbohydrate restriction. There are three methods for measuring ketone bodies. Urine ketone analysis (AcAc) is a standard clinical test, whereas blood ketone testing (BHB+AcAc) is valuable in identifying or resolving diabetic ketoacidosis. Recently, technology for measuring breath acetone has been introduced, which provides an easy means of monitoring ketogenic diets in obese individuals. The basic breath alcohol detector also reacts with breath acetone. Therefore, it is important for professional drivers taking SGLT2 inhibitors to be cautious as workplace breath alcohol detectors may show false-positive results. Conversely, if a positive result is obtained, a detailed examination of ketosis is necessary. This review provides an overview of ketone body measurements in individuals with diabetes.
期刊介绍:
Diabetology International, the official journal of the Japan Diabetes Society, publishes original research articles about experimental research and clinical studies in diabetes and related areas. The journal also presents editorials, reviews, commentaries, reports of expert committees, and case reports on any aspect of diabetes. Diabetology International welcomes submissions from researchers, clinicians, and health professionals throughout the world who are interested in research, treatment, and care of patients with diabetes. All manuscripts are peer-reviewed to assure that high-quality information in the field of diabetes is made available to readers. Manuscripts are reviewed with due respect for the author''s confidentiality. At the same time, reviewers also have rights to confidentiality, which are respected by the editors. The journal follows a single-blind review procedure, where the reviewers are aware of the names and affiliations of the authors, but the reviewer reports provided to authors are anonymous. Single-blind peer review is the traditional model of peer review that many reviewers are comfortable with, and it facilitates a dispassionate critique of a manuscript.