使用地塞米松植入物治疗玻璃体旁切除术和原发性视网膜外膜切除术后的黄斑水肿。

IF 1.4 4区 医学 Q3 OPHTHALMOLOGY International Ophthalmology Pub Date : 2024-08-05 DOI:10.1007/s10792-024-03258-8
Ali Altan Ertan Boz, Erkan Çelik, Mahmut Atum, Burçin Çakır, Nilgün Özkan Aksoy, Sedat Özmen, Emine Doğan, İsa Yuvacı
{"title":"使用地塞米松植入物治疗玻璃体旁切除术和原发性视网膜外膜切除术后的黄斑水肿。","authors":"Ali Altan Ertan Boz, Erkan Çelik, Mahmut Atum, Burçin Çakır, Nilgün Özkan Aksoy, Sedat Özmen, Emine Doğan, İsa Yuvacı","doi":"10.1007/s10792-024-03258-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to evaluate the effectiveness and safety of an intravitreal dexamethasone (DEX) implant for the treatment of macular edema (ME) following pars plana vitrectomy (PPV) and removal of the primary epiretinal membrane (ERM) and to assess the impact of the integrity of the ellipsoid zone (EZ) and disorganization of the retinal inner layer (DRIL) grade on visual and anatomical outcomes.</p><p><strong>Methods: </strong>Forty-two pseudophakic patients who developed ME following PPV and removal of the primary stage 2-3 ERM were included. Patients were divided into two groups when ME was diagnosed via spectral domain optic coherence tomography (SD-OCT). In the DEX group (n = 22), DEX was implanted for the treatment of ME. In the control group (n = 20), only observation was conducted, without any treatment. The best-corrected visual acuity (BCVA) and macular thickness (MT) of the two groups were compared at baseline and 1, 6, and 12 months after DEX implantation. The effects of OCT parameters such as EZ integrity and DRIL grade were also evaluated in terms of decreases in MT and increases in VA in the treatment of ME with DEX implantation. Intraocular pressure (IOP), number of DEX implantations and adverse effects were also recorded.</p><p><strong>Results: </strong>While a statistically significant increase in the mean BCVA was observed in the DEX group (p < 0.001 at months 1, 6, and 12, respectively), no such increase was detected in the control group (p = 0.169, p = 0.065, and p = 0.058 at months 1, 6 and 12, respectively) compared with the baseline. A statistically significant decrease in the mean MT was observed in the DEX group (p  < 0.001 at months 1, 6, and 12); however, no significant difference was observed in the control group (p  = 0.081, p  = 0.065, and p  = 0.054 at months 1, 6 and 12, respectively) compared with the baseline. Significant differences were found between the two groups in terms of the increase in BCVA (p  < 0.01) and decrease in MT (p  < 0.01) at all visits, with the outcomes being more favorable in the DEX group. A statistically significant relationship was found between the increase in VA and EZ integrity and DRIL grade in both groups. Ten patients (45.4%) received two injections of DEX during the follow-up. An increase in IOP was observed in five patients (22.7%) who were treated with topical antiglaucomatous drops. No significant side effects were observed.</p><p><strong>Conclusion: </strong>DEX implantation was found to be effective and safe for the treatment of ME following PPV and primary ERM removal, although some eyes may require repeated injections to achieve visual and anatomical success. Additionally, a relationship was found between EZ integrity, DRIL grade and visual-anatomical outcomes.</p>","PeriodicalId":14473,"journal":{"name":"International Ophthalmology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of a dexamethasone implant to treat macular edema following pars plana vitrectomy and removal of the primary epiretinal membrane.\",\"authors\":\"Ali Altan Ertan Boz, Erkan Çelik, Mahmut Atum, Burçin Çakır, Nilgün Özkan Aksoy, Sedat Özmen, Emine Doğan, İsa Yuvacı\",\"doi\":\"10.1007/s10792-024-03258-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of this study was to evaluate the effectiveness and safety of an intravitreal dexamethasone (DEX) implant for the treatment of macular edema (ME) following pars plana vitrectomy (PPV) and removal of the primary epiretinal membrane (ERM) and to assess the impact of the integrity of the ellipsoid zone (EZ) and disorganization of the retinal inner layer (DRIL) grade on visual and anatomical outcomes.</p><p><strong>Methods: </strong>Forty-two pseudophakic patients who developed ME following PPV and removal of the primary stage 2-3 ERM were included. Patients were divided into two groups when ME was diagnosed via spectral domain optic coherence tomography (SD-OCT). In the DEX group (n = 22), DEX was implanted for the treatment of ME. In the control group (n = 20), only observation was conducted, without any treatment. The best-corrected visual acuity (BCVA) and macular thickness (MT) of the two groups were compared at baseline and 1, 6, and 12 months after DEX implantation. The effects of OCT parameters such as EZ integrity and DRIL grade were also evaluated in terms of decreases in MT and increases in VA in the treatment of ME with DEX implantation. Intraocular pressure (IOP), number of DEX implantations and adverse effects were also recorded.</p><p><strong>Results: </strong>While a statistically significant increase in the mean BCVA was observed in the DEX group (p < 0.001 at months 1, 6, and 12, respectively), no such increase was detected in the control group (p = 0.169, p = 0.065, and p = 0.058 at months 1, 6 and 12, respectively) compared with the baseline. A statistically significant decrease in the mean MT was observed in the DEX group (p  < 0.001 at months 1, 6, and 12); however, no significant difference was observed in the control group (p  = 0.081, p  = 0.065, and p  = 0.054 at months 1, 6 and 12, respectively) compared with the baseline. Significant differences were found between the two groups in terms of the increase in BCVA (p  < 0.01) and decrease in MT (p  < 0.01) at all visits, with the outcomes being more favorable in the DEX group. A statistically significant relationship was found between the increase in VA and EZ integrity and DRIL grade in both groups. Ten patients (45.4%) received two injections of DEX during the follow-up. An increase in IOP was observed in five patients (22.7%) who were treated with topical antiglaucomatous drops. No significant side effects were observed.</p><p><strong>Conclusion: </strong>DEX implantation was found to be effective and safe for the treatment of ME following PPV and primary ERM removal, although some eyes may require repeated injections to achieve visual and anatomical success. Additionally, a relationship was found between EZ integrity, DRIL grade and visual-anatomical outcomes.</p>\",\"PeriodicalId\":14473,\"journal\":{\"name\":\"International Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10792-024-03258-8\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10792-024-03258-8","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是评估玻璃体旁切除术(PPV)和原发性视网膜外膜(ERM)切除术后植入玻璃体内地塞米松(DEX)治疗黄斑水肿(ME)的有效性和安全性,并评估椭圆形区(EZ)的完整性和视网膜内层(DRIL)的紊乱程度对视觉和解剖结果的影响:方法:纳入42例在PPV和原发性2-3期ERM摘除术后出现ME的假性角膜患者。通过光谱域光学相干断层扫描(SD-OCT)确诊为 ME 的患者被分为两组。DEX组(22人)植入DEX治疗ME。对照组(n = 20)只进行观察,不进行任何治疗。两组患者的最佳矫正视力(BCVA)和黄斑厚度(MT)在基线和植入 DEX 后 1、6 和 12 个月时进行了比较。此外,还评估了OCT参数(如EZ完整性和DRIL等级)对DEX植入治疗ME时MT下降和VA增加的影响。此外,还记录了眼内压(IOP)、DEX 植入次数和不良反应:结果:虽然在 DEX 组观察到平均 BCVA 有统计学意义的增加(P尽管有些眼球可能需要重复注射才能获得视觉和解剖上的成功,但研究发现,DEX 植入对于 PPV 和原发性 ERM 切除术后的 ME 治疗是有效和安全的。此外,研究还发现 EZ 完整性、DRIL 等级和视觉解剖结果之间存在关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Use of a dexamethasone implant to treat macular edema following pars plana vitrectomy and removal of the primary epiretinal membrane.

Purpose: The purpose of this study was to evaluate the effectiveness and safety of an intravitreal dexamethasone (DEX) implant for the treatment of macular edema (ME) following pars plana vitrectomy (PPV) and removal of the primary epiretinal membrane (ERM) and to assess the impact of the integrity of the ellipsoid zone (EZ) and disorganization of the retinal inner layer (DRIL) grade on visual and anatomical outcomes.

Methods: Forty-two pseudophakic patients who developed ME following PPV and removal of the primary stage 2-3 ERM were included. Patients were divided into two groups when ME was diagnosed via spectral domain optic coherence tomography (SD-OCT). In the DEX group (n = 22), DEX was implanted for the treatment of ME. In the control group (n = 20), only observation was conducted, without any treatment. The best-corrected visual acuity (BCVA) and macular thickness (MT) of the two groups were compared at baseline and 1, 6, and 12 months after DEX implantation. The effects of OCT parameters such as EZ integrity and DRIL grade were also evaluated in terms of decreases in MT and increases in VA in the treatment of ME with DEX implantation. Intraocular pressure (IOP), number of DEX implantations and adverse effects were also recorded.

Results: While a statistically significant increase in the mean BCVA was observed in the DEX group (p < 0.001 at months 1, 6, and 12, respectively), no such increase was detected in the control group (p = 0.169, p = 0.065, and p = 0.058 at months 1, 6 and 12, respectively) compared with the baseline. A statistically significant decrease in the mean MT was observed in the DEX group (p  < 0.001 at months 1, 6, and 12); however, no significant difference was observed in the control group (p  = 0.081, p  = 0.065, and p  = 0.054 at months 1, 6 and 12, respectively) compared with the baseline. Significant differences were found between the two groups in terms of the increase in BCVA (p  < 0.01) and decrease in MT (p  < 0.01) at all visits, with the outcomes being more favorable in the DEX group. A statistically significant relationship was found between the increase in VA and EZ integrity and DRIL grade in both groups. Ten patients (45.4%) received two injections of DEX during the follow-up. An increase in IOP was observed in five patients (22.7%) who were treated with topical antiglaucomatous drops. No significant side effects were observed.

Conclusion: DEX implantation was found to be effective and safe for the treatment of ME following PPV and primary ERM removal, although some eyes may require repeated injections to achieve visual and anatomical success. Additionally, a relationship was found between EZ integrity, DRIL grade and visual-anatomical outcomes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
0.00%
发文量
451
期刊介绍: International Ophthalmology provides the clinician with articles on all the relevant subspecialties of ophthalmology, with a broad international scope. The emphasis is on presentation of the latest clinical research in the field. In addition, the journal includes regular sections devoted to new developments in technologies, products, and techniques.
期刊最新文献
Comment on: intraocular pressure after combined photorefractive keratectomy and corneal collagen cross linking for keratoconus. Congential nasolacrimal duct obstruction: investigating the role of systemic inflammation through novel biomakers. The primary systemic vasculitis associated optic neuritis: a retrospective analysis in a single center over 10 years. Evaluation of the efficacy of subtenon autologous platelet-rich plasma therapy in patients with retinitis pigmentosa and factors affecting response to the treatment. Effect of upper eyelid blepharoplasty surgery on cornea biomechanics and ocular surface.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1