Katrijn R. Six , Sarah Vertongen , Sabrina Seghers , Dominique De Bleser , Veerle Compernolle , Hendrik B. Feys
{"title":"从不同血液成分的白细胞还原滤器中分离出来的白细胞的不同成分和产量。","authors":"Katrijn R. Six , Sarah Vertongen , Sabrina Seghers , Dominique De Bleser , Veerle Compernolle , Hendrik B. Feys","doi":"10.1016/j.jim.2024.113733","DOIUrl":null,"url":null,"abstract":"<div><p>In Flanders, an estimated 300,000 leukoreduction filters are discarded as biological waste in the blood establishment each year. These filters are a possible source of fresh donor leukocytes for downstream purposes including research. We investigated leukocyte isolation from two types of filters either used for the preparation of platelet concentrates (PC-LRF) or erythrocyte concentrates (EC-LRF). Outcome parameters were leukocyte yield, differential count, turnaround time and effect of storage conditions. Leukocytes were harvested by reverse flow of a buffer solution. Control was the gold standard density gradient centrifugation of buffy coats. Total leukocyte number isolated from PC-LRF (1049 (± 40) x 10<sup>6</sup>) was almost double that of control (632 (± 66) x 10<sup>6</sup>) but the differential count was comparable. Total leukocyte number isolated from EC-LRF (78 (± 9) x 10<sup>6</sup>) was significantly lower than control, but the sample was specifically enriched in granulocytes (81 ± 4%) compared to control (30 ± 1%). Isolation of leukocytes from either PC- or EC-LRF takes 20 min compared to 240 min for control density gradient centrifugation. Leukocyte viability is optimal when harvested on day 1 post donation (95 ± 0.9%) compared to day 3 (76.4 ± 2.4%). In conclusion, our study demonstrates that leukoreduction filters from specific blood component processing are easy to use and present a valuable source for viable leukocytes of all types.</p></div>","PeriodicalId":16000,"journal":{"name":"Journal of immunological methods","volume":"533 ","pages":"Article 113733"},"PeriodicalIF":1.6000,"publicationDate":"2024-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Differential composition and yield of leukocytes isolated from various blood component leukoreduction filters\",\"authors\":\"Katrijn R. Six , Sarah Vertongen , Sabrina Seghers , Dominique De Bleser , Veerle Compernolle , Hendrik B. Feys\",\"doi\":\"10.1016/j.jim.2024.113733\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In Flanders, an estimated 300,000 leukoreduction filters are discarded as biological waste in the blood establishment each year. These filters are a possible source of fresh donor leukocytes for downstream purposes including research. We investigated leukocyte isolation from two types of filters either used for the preparation of platelet concentrates (PC-LRF) or erythrocyte concentrates (EC-LRF). Outcome parameters were leukocyte yield, differential count, turnaround time and effect of storage conditions. Leukocytes were harvested by reverse flow of a buffer solution. Control was the gold standard density gradient centrifugation of buffy coats. Total leukocyte number isolated from PC-LRF (1049 (± 40) x 10<sup>6</sup>) was almost double that of control (632 (± 66) x 10<sup>6</sup>) but the differential count was comparable. Total leukocyte number isolated from EC-LRF (78 (± 9) x 10<sup>6</sup>) was significantly lower than control, but the sample was specifically enriched in granulocytes (81 ± 4%) compared to control (30 ± 1%). Isolation of leukocytes from either PC- or EC-LRF takes 20 min compared to 240 min for control density gradient centrifugation. Leukocyte viability is optimal when harvested on day 1 post donation (95 ± 0.9%) compared to day 3 (76.4 ± 2.4%). In conclusion, our study demonstrates that leukoreduction filters from specific blood component processing are easy to use and present a valuable source for viable leukocytes of all types.</p></div>\",\"PeriodicalId\":16000,\"journal\":{\"name\":\"Journal of immunological methods\",\"volume\":\"533 \",\"pages\":\"Article 113733\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-08-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of immunological methods\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0022175924001182\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of immunological methods","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022175924001182","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Differential composition and yield of leukocytes isolated from various blood component leukoreduction filters
In Flanders, an estimated 300,000 leukoreduction filters are discarded as biological waste in the blood establishment each year. These filters are a possible source of fresh donor leukocytes for downstream purposes including research. We investigated leukocyte isolation from two types of filters either used for the preparation of platelet concentrates (PC-LRF) or erythrocyte concentrates (EC-LRF). Outcome parameters were leukocyte yield, differential count, turnaround time and effect of storage conditions. Leukocytes were harvested by reverse flow of a buffer solution. Control was the gold standard density gradient centrifugation of buffy coats. Total leukocyte number isolated from PC-LRF (1049 (± 40) x 106) was almost double that of control (632 (± 66) x 106) but the differential count was comparable. Total leukocyte number isolated from EC-LRF (78 (± 9) x 106) was significantly lower than control, but the sample was specifically enriched in granulocytes (81 ± 4%) compared to control (30 ± 1%). Isolation of leukocytes from either PC- or EC-LRF takes 20 min compared to 240 min for control density gradient centrifugation. Leukocyte viability is optimal when harvested on day 1 post donation (95 ± 0.9%) compared to day 3 (76.4 ± 2.4%). In conclusion, our study demonstrates that leukoreduction filters from specific blood component processing are easy to use and present a valuable source for viable leukocytes of all types.
期刊介绍:
The Journal of Immunological Methods is devoted to covering techniques for: (1) Quantitating and detecting antibodies and/or antigens. (2) Purifying immunoglobulins, lymphokines and other molecules of the immune system. (3) Isolating antigens and other substances important in immunological processes. (4) Labelling antigens and antibodies. (5) Localizing antigens and/or antibodies in tissues and cells. (6) Detecting, and fractionating immunocompetent cells. (7) Assaying for cellular immunity. (8) Documenting cell-cell interactions. (9) Initiating immunity and unresponsiveness. (10) Transplanting tissues. (11) Studying items closely related to immunity such as complement, reticuloendothelial system and others. (12) Molecular techniques for studying immune cells and their receptors. (13) Imaging of the immune system. (14) Methods for production or their fragments in eukaryotic and prokaryotic cells.
In addition the journal will publish articles on novel methods for analysing the organization, structure and expression of genes for immunologically important molecules such as immunoglobulins, T cell receptors and accessory molecules involved in antigen recognition, processing and presentation. Submitted full length manuscripts should describe new methods of broad applicability to immunology and not simply the application of an established method to a particular substance - although papers describing such applications may be considered for publication as a short Technical Note. Review articles will also be published by the Journal of Immunological Methods. In general these manuscripts are by solicitation however anyone interested in submitting a review can contact the Reviews Editor and provide an outline of the proposed review.