{"title":"通过舌下含服硝酸甘油对亚当凯维奇动脉进行计算机断层扫描血管造影评估。","authors":"Akio Higuchi, Yoshihiro Kubota, Hajime Yokota, Hiroki Miyazaki, Joji Ota, Yasuaki Okafuji, Hiroyuki Takaoka, Takashi Uno","doi":"10.1007/s00234-024-03433-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Identification of the Adamkiewicz artery before aortic surgery is important for preventing postoperative complications due to spinal cord ischemia. The Adamkiewicz artery is difficult to identify due to its small diameter. Nitroglycerin has a vasodilatory effect and is used clinically to improve visualization of blood vessels on coronary computed tomography (CT) angiography. We investigated whether the vasodilatory effect of nitroglycerin could improve the ability to visualize the Adamkiewicz artery.</p><p><strong>Methods: </strong>We extracted 33 cases wherein contrast-enhanced CT images were taken before and after aortic aneurysm surgery. Nitroglycerin was administered for coronary artery evaluation on the preoperative CT. However, no nitroglycerin was administered before the postoperative CT. Aortic contrast-to-noise ratio, CT value, image noise, and diameter of the Adamkiewicz artery and anterior spinal artery were measured. The depiction of the Adamkiewicz artery was graded into four grades and evaluated. These measurements were performed by two independent reviewers.</p><p><strong>Results: </strong>In nitroglycerin-administered cases, the contrast-to-noise ratio and CT values were significantly higher (P < 0.001, P < 0.001, respectively); the Adamkiewicz artery and anterior spinal artery diameters were dilated (P = 0.005, P = 0.001, respectively). The Adamkiewicz artery score also improved significantly (P < 0.001). No significant difference was found in image noise.</p><p><strong>Conclusion: </strong>Nitroglycerin contributed to improving the Adamkiewicz artery's visualization.</p>","PeriodicalId":19422,"journal":{"name":"Neuroradiology","volume":" ","pages":"2215-2221"},"PeriodicalIF":2.4000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Computed tomography angiography assessment of Adamkiewicz artery with sublingual nitroglycerin administration.\",\"authors\":\"Akio Higuchi, Yoshihiro Kubota, Hajime Yokota, Hiroki Miyazaki, Joji Ota, Yasuaki Okafuji, Hiroyuki Takaoka, Takashi Uno\",\"doi\":\"10.1007/s00234-024-03433-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Identification of the Adamkiewicz artery before aortic surgery is important for preventing postoperative complications due to spinal cord ischemia. The Adamkiewicz artery is difficult to identify due to its small diameter. Nitroglycerin has a vasodilatory effect and is used clinically to improve visualization of blood vessels on coronary computed tomography (CT) angiography. We investigated whether the vasodilatory effect of nitroglycerin could improve the ability to visualize the Adamkiewicz artery.</p><p><strong>Methods: </strong>We extracted 33 cases wherein contrast-enhanced CT images were taken before and after aortic aneurysm surgery. Nitroglycerin was administered for coronary artery evaluation on the preoperative CT. However, no nitroglycerin was administered before the postoperative CT. Aortic contrast-to-noise ratio, CT value, image noise, and diameter of the Adamkiewicz artery and anterior spinal artery were measured. The depiction of the Adamkiewicz artery was graded into four grades and evaluated. These measurements were performed by two independent reviewers.</p><p><strong>Results: </strong>In nitroglycerin-administered cases, the contrast-to-noise ratio and CT values were significantly higher (P < 0.001, P < 0.001, respectively); the Adamkiewicz artery and anterior spinal artery diameters were dilated (P = 0.005, P = 0.001, respectively). The Adamkiewicz artery score also improved significantly (P < 0.001). No significant difference was found in image noise.</p><p><strong>Conclusion: </strong>Nitroglycerin contributed to improving the Adamkiewicz artery's visualization.</p>\",\"PeriodicalId\":19422,\"journal\":{\"name\":\"Neuroradiology\",\"volume\":\" \",\"pages\":\"2215-2221\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Neuroradiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00234-024-03433-9\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00234-024-03433-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/5 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
Computed tomography angiography assessment of Adamkiewicz artery with sublingual nitroglycerin administration.
Purpose: Identification of the Adamkiewicz artery before aortic surgery is important for preventing postoperative complications due to spinal cord ischemia. The Adamkiewicz artery is difficult to identify due to its small diameter. Nitroglycerin has a vasodilatory effect and is used clinically to improve visualization of blood vessels on coronary computed tomography (CT) angiography. We investigated whether the vasodilatory effect of nitroglycerin could improve the ability to visualize the Adamkiewicz artery.
Methods: We extracted 33 cases wherein contrast-enhanced CT images were taken before and after aortic aneurysm surgery. Nitroglycerin was administered for coronary artery evaluation on the preoperative CT. However, no nitroglycerin was administered before the postoperative CT. Aortic contrast-to-noise ratio, CT value, image noise, and diameter of the Adamkiewicz artery and anterior spinal artery were measured. The depiction of the Adamkiewicz artery was graded into four grades and evaluated. These measurements were performed by two independent reviewers.
Results: In nitroglycerin-administered cases, the contrast-to-noise ratio and CT values were significantly higher (P < 0.001, P < 0.001, respectively); the Adamkiewicz artery and anterior spinal artery diameters were dilated (P = 0.005, P = 0.001, respectively). The Adamkiewicz artery score also improved significantly (P < 0.001). No significant difference was found in image noise.
Conclusion: Nitroglycerin contributed to improving the Adamkiewicz artery's visualization.
期刊介绍:
Neuroradiology aims to provide state-of-the-art medical and scientific information in the fields of Neuroradiology, Neurosciences, Neurology, Psychiatry, Neurosurgery, and related medical specialities. Neuroradiology as the official Journal of the European Society of Neuroradiology receives submissions from all parts of the world and publishes peer-reviewed original research, comprehensive reviews, educational papers, opinion papers, and short reports on exceptional clinical observations and new technical developments in the field of Neuroimaging and Neurointervention. The journal has subsections for Diagnostic and Interventional Neuroradiology, Advanced Neuroimaging, Paediatric Neuroradiology, Head-Neck-ENT Radiology, Spine Neuroradiology, and for submissions from Japan. Neuroradiology aims to provide new knowledge about and insights into the function and pathology of the human nervous system that may help to better diagnose and treat nervous system diseases. Neuroradiology is a member of the Committee on Publication Ethics (COPE) and follows the COPE core practices. Neuroradiology prefers articles that are free of bias, self-critical regarding limitations, transparent and clear in describing study participants, methods, and statistics, and short in presenting results. Before peer-review all submissions are automatically checked by iThenticate to assess for potential overlap in prior publication.