在诊断侵袭性曲霉菌病方面,半乳甘露聚糖 Ag VIRCLIA® Monotest 和 sõna 半乳甘露聚糖侧流检测法的性能相当。

IF 4.1 2区 医学 Q1 DERMATOLOGY Mycoses Pub Date : 2024-08-01 DOI:10.1111/myc.13782
Corinna Küpper, Timothy Moritz Erb, Johannes Träger, Lisa Meintker, Giuseppe Valenza, Christian Bogdan, Jürgen Held
{"title":"在诊断侵袭性曲霉菌病方面,半乳甘露聚糖 Ag VIRCLIA® Monotest 和 sõna 半乳甘露聚糖侧流检测法的性能相当。","authors":"Corinna Küpper, Timothy Moritz Erb, Johannes Träger, Lisa Meintker, Giuseppe Valenza, Christian Bogdan, Jürgen Held","doi":"10.1111/myc.13782","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Rapid galactomannan tests, such as the sõna Aspergillus GM Lateral Flow Assay (GM-LFA) and the Aspergillus Galactomannan Ag VIRCLIA® Monotest (GM-Monotest), which are suitable for the analysis of single samples, have the potential to accelerate diagnosis of invasive aspergillosis (IA).</p><p><strong>Objectives: </strong>To compare the performance of the GM-Monotest and the GM-LFA for the diagnosis of IA.</p><p><strong>Patients/methods: </strong>Two patient cohorts were analysed: adults who had received an allogeneic haematopoietic stem-cell transplant (alloHSCT-cohort) and patients with proven/probable IA from a 5-year period (cross-sectional IA-cohort). In the alloHSCT-cohort, weekly serum samples were tested, whereas in the cross-sectional IA-cohort sera and bronchoalveolar lavage fluids were analysed. The diagnostic performance was calculated using two definitions for positivity: (1) a single positive GM result and (2) at least two positive GM results from consecutive samples. IA classification followed EORTC/MSG 2019.</p><p><strong>Results: </strong>The alloHSCT-cohort included 101 patients. Four had proven/probable IA, 26 possible IA and 71 no IA. The specificity for one positive serum and two consecutively positive sera was 88.7% and 100% (GM-Monotest) and 85.9% and 98.6% (GM-LFA). Comparison of ROC curves in the alloHSCT-cohort showed no significant difference. The cross-sectional IA-cohort included 59 patients with proven/probable IA. The sensitivity for one positive sample and two consecutively positive samples was 83.1% and 55.1% (GM-Monotest) and 86.4% and 71.4% (GM-LFA).</p><p><strong>Conclusions: </strong>Both assays showed comparable diagnostic performance with a higher sensitivity for the GM-LFA if two consecutive positive samples were required for positivity. However, due to poor reproducibility, positive GM-LFA results should always be confirmed.</p>","PeriodicalId":18797,"journal":{"name":"Mycoses","volume":"67 8","pages":"e13782"},"PeriodicalIF":4.1000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Aspergillus galactomannan Ag VIRCLIA® Monotest and the sõna Aspergillus galactomannan lateral flow assay show comparable performance for the diagnosis of invasive aspergillosis.\",\"authors\":\"Corinna Küpper, Timothy Moritz Erb, Johannes Träger, Lisa Meintker, Giuseppe Valenza, Christian Bogdan, Jürgen Held\",\"doi\":\"10.1111/myc.13782\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Rapid galactomannan tests, such as the sõna Aspergillus GM Lateral Flow Assay (GM-LFA) and the Aspergillus Galactomannan Ag VIRCLIA® Monotest (GM-Monotest), which are suitable for the analysis of single samples, have the potential to accelerate diagnosis of invasive aspergillosis (IA).</p><p><strong>Objectives: </strong>To compare the performance of the GM-Monotest and the GM-LFA for the diagnosis of IA.</p><p><strong>Patients/methods: </strong>Two patient cohorts were analysed: adults who had received an allogeneic haematopoietic stem-cell transplant (alloHSCT-cohort) and patients with proven/probable IA from a 5-year period (cross-sectional IA-cohort). In the alloHSCT-cohort, weekly serum samples were tested, whereas in the cross-sectional IA-cohort sera and bronchoalveolar lavage fluids were analysed. The diagnostic performance was calculated using two definitions for positivity: (1) a single positive GM result and (2) at least two positive GM results from consecutive samples. IA classification followed EORTC/MSG 2019.</p><p><strong>Results: </strong>The alloHSCT-cohort included 101 patients. Four had proven/probable IA, 26 possible IA and 71 no IA. The specificity for one positive serum and two consecutively positive sera was 88.7% and 100% (GM-Monotest) and 85.9% and 98.6% (GM-LFA). Comparison of ROC curves in the alloHSCT-cohort showed no significant difference. The cross-sectional IA-cohort included 59 patients with proven/probable IA. The sensitivity for one positive sample and two consecutively positive samples was 83.1% and 55.1% (GM-Monotest) and 86.4% and 71.4% (GM-LFA).</p><p><strong>Conclusions: </strong>Both assays showed comparable diagnostic performance with a higher sensitivity for the GM-LFA if two consecutive positive samples were required for positivity. However, due to poor reproducibility, positive GM-LFA results should always be confirmed.</p>\",\"PeriodicalId\":18797,\"journal\":{\"name\":\"Mycoses\",\"volume\":\"67 8\",\"pages\":\"e13782\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mycoses\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/myc.13782\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DERMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mycoses","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/myc.13782","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DERMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:快速半乳甘露聚糖检测试剂盒,如sõna曲霉菌GM侧流检测试剂盒(GM-LFA)和曲霉菌半乳甘露聚糖Ag VIRCLIA®单测试剂盒(GM-Monotest),适用于单份样本的分析,有望加速侵袭性曲霉菌病(IA)的诊断:目的:比较GM-Monotest和GM-LFA诊断侵袭性曲霉病的性能:分析了两个患者队列:接受过异体造血干细胞移植的成人(alloHSCT队列)和5年内证实/可能患有曲霉菌病的患者(横断面曲霉菌病队列)。异体干细胞移植队列每周检测血清样本,而横断面IA队列则分析血清和支气管肺泡灌洗液。诊断效果采用两种阳性定义进行计算:(1) 单个 GM 阳性结果;(2) 连续样本中至少有两个 GM 阳性结果。IA分类遵循 EORTC/MSG 2019:alloHSCT队列包括101名患者。其中 4 人已证实/可能有免疫缺陷病毒,26 人可能有免疫缺陷病毒,71 人没有免疫缺陷病毒。一份阳性血清和两份连续阳性血清的特异性分别为88.7%和100%(GM-Monotest)以及85.9%和98.6%(GM-LFA)。alloHSCT队列的ROC曲线比较结果显示无明显差异。横断面IA队列包括59名已证实/可能患有IA的患者。一个阳性样本和两个连续阳性样本的灵敏度分别为83.1%和55.1%(GM-Monotest)和86.4%和71.4%(GM-LFA):两种检测方法的诊断性能相当,但如果需要两个连续的阳性样本才能呈阳性,GM-LFA 的灵敏度更高。然而,由于重现性较差,GM-LFA 阳性结果应始终得到确认。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Aspergillus galactomannan Ag VIRCLIA® Monotest and the sõna Aspergillus galactomannan lateral flow assay show comparable performance for the diagnosis of invasive aspergillosis.

Background: Rapid galactomannan tests, such as the sõna Aspergillus GM Lateral Flow Assay (GM-LFA) and the Aspergillus Galactomannan Ag VIRCLIA® Monotest (GM-Monotest), which are suitable for the analysis of single samples, have the potential to accelerate diagnosis of invasive aspergillosis (IA).

Objectives: To compare the performance of the GM-Monotest and the GM-LFA for the diagnosis of IA.

Patients/methods: Two patient cohorts were analysed: adults who had received an allogeneic haematopoietic stem-cell transplant (alloHSCT-cohort) and patients with proven/probable IA from a 5-year period (cross-sectional IA-cohort). In the alloHSCT-cohort, weekly serum samples were tested, whereas in the cross-sectional IA-cohort sera and bronchoalveolar lavage fluids were analysed. The diagnostic performance was calculated using two definitions for positivity: (1) a single positive GM result and (2) at least two positive GM results from consecutive samples. IA classification followed EORTC/MSG 2019.

Results: The alloHSCT-cohort included 101 patients. Four had proven/probable IA, 26 possible IA and 71 no IA. The specificity for one positive serum and two consecutively positive sera was 88.7% and 100% (GM-Monotest) and 85.9% and 98.6% (GM-LFA). Comparison of ROC curves in the alloHSCT-cohort showed no significant difference. The cross-sectional IA-cohort included 59 patients with proven/probable IA. The sensitivity for one positive sample and two consecutively positive samples was 83.1% and 55.1% (GM-Monotest) and 86.4% and 71.4% (GM-LFA).

Conclusions: Both assays showed comparable diagnostic performance with a higher sensitivity for the GM-LFA if two consecutive positive samples were required for positivity. However, due to poor reproducibility, positive GM-LFA results should always be confirmed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Mycoses
Mycoses 医学-皮肤病学
CiteScore
10.00
自引率
8.20%
发文量
143
审稿时长
6-12 weeks
期刊介绍: The journal Mycoses provides an international forum for original papers in English on the pathogenesis, diagnosis, therapy, prophylaxis, and epidemiology of fungal infectious diseases in humans as well as on the biology of pathogenic fungi. Medical mycology as part of medical microbiology is advancing rapidly. Effective therapeutic strategies are already available in chemotherapy and are being further developed. Their application requires reliable laboratory diagnostic techniques, which, in turn, result from mycological basic research. Opportunistic mycoses vary greatly in their clinical and pathological symptoms, because the underlying disease of a patient at risk decisively determines their symptomatology and progress. The journal Mycoses is therefore of interest to scientists in fundamental mycological research, mycological laboratory diagnosticians and clinicians interested in fungal infections.
期刊最新文献
High-Resolution Melting Assay to Detect the Mutations That Cause the Y132F and G458S Substitutions at the ERG11 Gene Involved in Azole Resistance in Candida parapsilosis. First Reported Cases of Terbinafine-Resistant Trichophyton indotineae Isolates in Israel: Epidemiology, Clinical Characteristics and Response to Treatment. Multicentre Study of Candida parapsilosis Blood Isolates in Türkiye Highlights an Increasing Rate of Fluconazole Resistance and Emergence of Echinocandin and Multidrug Resistance. The In Vitro Activity of Rezafungin Against Uncommon Species of Candida. Detecting Echinocandin Resistance in C. glabrata Using Commercial Methods: Are CLSI or EUCAST Breakpoints Suitable for Categorical Classification?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1