利用电化学芯片实验室对尿路感染进行多重抗生素药敏试验。

IF 3 4区 医学 Q3 ENGINEERING, BIOMEDICAL Biomedical Microdevices Pub Date : 2024-08-09 DOI:10.1007/s10544-024-00719-w
Benjamin Crane, Alex Iles, Craig E. Banks, Mamun Rashid, Patricia E. Linton, Kirsty J. Shaw
{"title":"利用电化学芯片实验室对尿路感染进行多重抗生素药敏试验。","authors":"Benjamin Crane,&nbsp;Alex Iles,&nbsp;Craig E. Banks,&nbsp;Mamun Rashid,&nbsp;Patricia E. Linton,&nbsp;Kirsty J. Shaw","doi":"10.1007/s10544-024-00719-w","DOIUrl":null,"url":null,"abstract":"<div><p>Urinary tract infections (UTIs) represent the most prevalent type of outpatient infection, with significant adverse health and economic burdens. Current culture-based antibiotic susceptibility testing can take up to 72 h resulting in ineffective prescription of broad-spectrum antibiotics, poor clinical outcomes and development of further antibiotic resistance. We report an electrochemical lab-on-a-chip (LOC) for testing samples against seven clinically-relevant antibiotics. The LOC contained eight chambers, each housing an antibiotic-loaded hydrogel (cephalexin, ceftriaxone, colistin, gentamicin, piperacillin, trimethoprim, vancomycin) or antibiotic-free control, alongside a resazurin bulk-modified screen-printed electrode for electrochemical detection of metabolically active bacteria using differential pulse voltammetry. Antibiotic susceptibility in simulated UTI samples or donated human urine with either <i>Escherichia coli</i> or <i>Klebsiella pneumoniae</i> could be established within 85 min. Incorporating electrochemical detection onto a LOC provides an inexpensive, simple method for the sensitive determination of antibiotic susceptibility that is significantly faster than using a culture-based approach.</p></div>","PeriodicalId":490,"journal":{"name":"Biomedical Microdevices","volume":"26 3","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11315706/pdf/","citationCount":"0","resultStr":"{\"title\":\"Multiplex antibiotic susceptibility testing of urinary tract infections using an electrochemical lab-on-a-chip\",\"authors\":\"Benjamin Crane,&nbsp;Alex Iles,&nbsp;Craig E. Banks,&nbsp;Mamun Rashid,&nbsp;Patricia E. Linton,&nbsp;Kirsty J. Shaw\",\"doi\":\"10.1007/s10544-024-00719-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Urinary tract infections (UTIs) represent the most prevalent type of outpatient infection, with significant adverse health and economic burdens. Current culture-based antibiotic susceptibility testing can take up to 72 h resulting in ineffective prescription of broad-spectrum antibiotics, poor clinical outcomes and development of further antibiotic resistance. We report an electrochemical lab-on-a-chip (LOC) for testing samples against seven clinically-relevant antibiotics. The LOC contained eight chambers, each housing an antibiotic-loaded hydrogel (cephalexin, ceftriaxone, colistin, gentamicin, piperacillin, trimethoprim, vancomycin) or antibiotic-free control, alongside a resazurin bulk-modified screen-printed electrode for electrochemical detection of metabolically active bacteria using differential pulse voltammetry. Antibiotic susceptibility in simulated UTI samples or donated human urine with either <i>Escherichia coli</i> or <i>Klebsiella pneumoniae</i> could be established within 85 min. Incorporating electrochemical detection onto a LOC provides an inexpensive, simple method for the sensitive determination of antibiotic susceptibility that is significantly faster than using a culture-based approach.</p></div>\",\"PeriodicalId\":490,\"journal\":{\"name\":\"Biomedical Microdevices\",\"volume\":\"26 3\",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11315706/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Microdevices\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10544-024-00719-w\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Microdevices","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10544-024-00719-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

尿路感染(UTI)是最常见的门诊感染类型,对健康和经济造成严重的负面影响。目前以培养为基础的抗生素药敏测试可能需要 72 小时,结果导致广谱抗生素处方无效、临床疗效不佳以及抗生素耐药性的进一步发展。我们报告了一种电化学片上实验室(LOC),用于检测样本对七种临床相关抗生素的敏感性。该实验室芯片包含八个腔室,每个腔室都装有抗生素水凝胶(头孢氨苄、头孢曲松、可乐定、庆大霉素、哌拉西林、曲美普林、万古霉素)或不含抗生素的对照品,同时还有一个利马唑林改性丝网印刷电极,用于利用差分脉冲伏安法对代谢活跃的细菌进行电化学检测。可在 85 分钟内确定模拟 UTI 样品或捐赠人尿液中大肠埃希菌或肺炎克雷伯菌对抗生素的敏感性。在 LOC 中加入电化学检测技术可提供一种廉价、简单的方法,用于灵敏测定抗生素敏感性,其速度明显快于基于培养的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Multiplex antibiotic susceptibility testing of urinary tract infections using an electrochemical lab-on-a-chip

Urinary tract infections (UTIs) represent the most prevalent type of outpatient infection, with significant adverse health and economic burdens. Current culture-based antibiotic susceptibility testing can take up to 72 h resulting in ineffective prescription of broad-spectrum antibiotics, poor clinical outcomes and development of further antibiotic resistance. We report an electrochemical lab-on-a-chip (LOC) for testing samples against seven clinically-relevant antibiotics. The LOC contained eight chambers, each housing an antibiotic-loaded hydrogel (cephalexin, ceftriaxone, colistin, gentamicin, piperacillin, trimethoprim, vancomycin) or antibiotic-free control, alongside a resazurin bulk-modified screen-printed electrode for electrochemical detection of metabolically active bacteria using differential pulse voltammetry. Antibiotic susceptibility in simulated UTI samples or donated human urine with either Escherichia coli or Klebsiella pneumoniae could be established within 85 min. Incorporating electrochemical detection onto a LOC provides an inexpensive, simple method for the sensitive determination of antibiotic susceptibility that is significantly faster than using a culture-based approach.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedical Microdevices
Biomedical Microdevices 工程技术-工程:生物医学
CiteScore
6.90
自引率
3.60%
发文量
32
审稿时长
6 months
期刊介绍: Biomedical Microdevices: BioMEMS and Biomedical Nanotechnology is an interdisciplinary periodical devoted to all aspects of research in the medical diagnostic and therapeutic applications of Micro-Electro-Mechanical Systems (BioMEMS) and nanotechnology for medicine and biology. General subjects of interest include the design, characterization, testing, modeling and clinical validation of microfabricated systems, and their integration on-chip and in larger functional units. The specific interests of the Journal include systems for neural stimulation and recording, bioseparation technologies such as nanofilters and electrophoretic equipment, miniaturized analytic and DNA identification systems, biosensors, and micro/nanotechnologies for cell and tissue research, tissue engineering, cell transplantation, and the controlled release of drugs and biological molecules. Contributions reporting on fundamental and applied investigations of the material science, biochemistry, and physics of biomedical microdevices and nanotechnology are encouraged. A non-exhaustive list of fields of interest includes: nanoparticle synthesis, characterization, and validation of therapeutic or imaging efficacy in animal models; biocompatibility; biochemical modification of microfabricated devices, with reference to non-specific protein adsorption, and the active immobilization and patterning of proteins on micro/nanofabricated surfaces; the dynamics of fluids in micro-and-nano-fabricated channels; the electromechanical and structural response of micro/nanofabricated systems; the interactions of microdevices with cells and tissues, including biocompatibility and biodegradation studies; variations in the characteristics of the systems as a function of the micro/nanofabrication parameters.
期刊最新文献
Smartphone-driven centrifugal microfluidics for diagnostics in resource limited settings Enhancing biomedical imaging: the role of nanoparticle-based contrast agents Panoramic review on polymeric microneedle arrays for clinical applications Construction of a pumpless gravity-driven vascularized Skin-on-a-Chip for the study of hepatocytotoxicity in percutaneous exposure to exogenous chemicals Functionalization of microbubbles in a microfluidic chip for biosensing application
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1