使用三维光学设备预测阻塞性睡眠呼吸暂停低通气综合征:系统综述。

IF 2.9 3区 医学 Q2 HEALTH CARE SCIENCES & SERVICES DIGITAL HEALTH Pub Date : 2024-08-07 eCollection Date: 2024-01-01 DOI:10.1177/20552076241271749
Beibei Chen, Rongkai Cao, Danni Song, Piaopiao Qiu, Chongshan Liao, Yongming Li
{"title":"使用三维光学设备预测阻塞性睡眠呼吸暂停低通气综合征:系统综述。","authors":"Beibei Chen, Rongkai Cao, Danni Song, Piaopiao Qiu, Chongshan Liao, Yongming Li","doi":"10.1177/20552076241271749","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>As a global health concern, the diagnosis of obstructive sleep apnea hypopnea syndrome (OSAHS), characterized by partial reductions and complete pauses in ventilation, has garnered significant scientific and public attention. With the advancement of digital technology, the utilization of three-dimensional (3D) optical devices demonstrates unparalleled potential in diagnosing OSAHS. This study aimed to review the current literature to assess the accuracy of 3D optical devices in identifying the prevalence and severity of OSAHS.</p><p><strong>Methods: </strong>A systematic literature search was conducted in the Web of Science, Scopus, PubMed/MEDLINE, and Cochrane Library databases for English studies published up to April 2024. Peer-reviewed researches assessing the diagnostic utility of 3D optical devices for OSAHS were included. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) guideline was employed to appraise the risk of bias.</p><p><strong>Results: </strong>The search yielded 3216 results, with 10 articles meeting the inclusion criteria for this study. Selected studies utilized structured light scanners, stereophotogrammetry, and red, green, blue-depth (RGB-D) cameras. Stereophotogrammetry-based 3D optical devices exhibited promising potential in OSAHS prediction.</p><p><strong>Conclusions: </strong>The utilization of 3D optical devices holds considerable promise for OSAHS diagnosis, offering potential improvements in accuracy, cost reduction, and time efficiency. However, further clinical data are essential to assist clinicians in the early detection of OSAHS using 3D optical devices.</p>","PeriodicalId":51333,"journal":{"name":"DIGITAL HEALTH","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11307370/pdf/","citationCount":"0","resultStr":"{\"title\":\"Predicting obstructive sleep apnea hypopnea syndrome using three-dimensional optical devices: A systematic review.\",\"authors\":\"Beibei Chen, Rongkai Cao, Danni Song, Piaopiao Qiu, Chongshan Liao, Yongming Li\",\"doi\":\"10.1177/20552076241271749\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>As a global health concern, the diagnosis of obstructive sleep apnea hypopnea syndrome (OSAHS), characterized by partial reductions and complete pauses in ventilation, has garnered significant scientific and public attention. With the advancement of digital technology, the utilization of three-dimensional (3D) optical devices demonstrates unparalleled potential in diagnosing OSAHS. This study aimed to review the current literature to assess the accuracy of 3D optical devices in identifying the prevalence and severity of OSAHS.</p><p><strong>Methods: </strong>A systematic literature search was conducted in the Web of Science, Scopus, PubMed/MEDLINE, and Cochrane Library databases for English studies published up to April 2024. Peer-reviewed researches assessing the diagnostic utility of 3D optical devices for OSAHS were included. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) guideline was employed to appraise the risk of bias.</p><p><strong>Results: </strong>The search yielded 3216 results, with 10 articles meeting the inclusion criteria for this study. Selected studies utilized structured light scanners, stereophotogrammetry, and red, green, blue-depth (RGB-D) cameras. Stereophotogrammetry-based 3D optical devices exhibited promising potential in OSAHS prediction.</p><p><strong>Conclusions: </strong>The utilization of 3D optical devices holds considerable promise for OSAHS diagnosis, offering potential improvements in accuracy, cost reduction, and time efficiency. However, further clinical data are essential to assist clinicians in the early detection of OSAHS using 3D optical devices.</p>\",\"PeriodicalId\":51333,\"journal\":{\"name\":\"DIGITAL HEALTH\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11307370/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"DIGITAL HEALTH\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/20552076241271749\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"HEALTH CARE SCIENCES & SERVICES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"DIGITAL HEALTH","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/20552076241271749","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

摘要

目的:阻塞性睡眠呼吸暂停低通气综合征(OSAHS)以通气量部分减少或完全暂停为特征,是一个全球关注的健康问题,其诊断引起了科学界和公众的极大关注。随着数字技术的发展,三维(3D)光学设备的应用在诊断 OSAHS 方面展现出无与伦比的潜力。本研究旨在回顾现有文献,评估三维光学设备在确定 OSAHS 患病率和严重程度方面的准确性:在 Web of Science、Scopus、PubMed/MEDLINE 和 Cochrane Library 数据库中对截至 2024 年 4 月发表的英文研究进行了系统的文献检索。纳入了评估 3D 光学设备对 OSAHS 诊断效用的同行评审研究。采用诊断准确性研究质量评估-2(QUADAS-2)指南评估偏倚风险:搜索结果有 3216 条,其中有 10 篇文章符合本研究的纳入标准。部分研究采用了结构光扫描仪、立体摄影测量法和红绿蓝深度(RGB-D)照相机。基于立体摄影测量技术的三维光学设备在 OSAHS 预测中表现出了巨大的潜力:结论:三维光学设备的使用为 OSAHS 诊断带来了巨大的前景,在准确性、降低成本和时间效率方面都有可能得到改善。然而,要帮助临床医生利用三维光学设备早期检测出 OSAHS,还需要更多的临床数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Predicting obstructive sleep apnea hypopnea syndrome using three-dimensional optical devices: A systematic review.

Purpose: As a global health concern, the diagnosis of obstructive sleep apnea hypopnea syndrome (OSAHS), characterized by partial reductions and complete pauses in ventilation, has garnered significant scientific and public attention. With the advancement of digital technology, the utilization of three-dimensional (3D) optical devices demonstrates unparalleled potential in diagnosing OSAHS. This study aimed to review the current literature to assess the accuracy of 3D optical devices in identifying the prevalence and severity of OSAHS.

Methods: A systematic literature search was conducted in the Web of Science, Scopus, PubMed/MEDLINE, and Cochrane Library databases for English studies published up to April 2024. Peer-reviewed researches assessing the diagnostic utility of 3D optical devices for OSAHS were included. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) guideline was employed to appraise the risk of bias.

Results: The search yielded 3216 results, with 10 articles meeting the inclusion criteria for this study. Selected studies utilized structured light scanners, stereophotogrammetry, and red, green, blue-depth (RGB-D) cameras. Stereophotogrammetry-based 3D optical devices exhibited promising potential in OSAHS prediction.

Conclusions: The utilization of 3D optical devices holds considerable promise for OSAHS diagnosis, offering potential improvements in accuracy, cost reduction, and time efficiency. However, further clinical data are essential to assist clinicians in the early detection of OSAHS using 3D optical devices.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
DIGITAL HEALTH
DIGITAL HEALTH Multiple-
CiteScore
2.90
自引率
7.70%
发文量
302
期刊最新文献
A feasibility study on utilizing machine learning technology to reduce the costs of gastric cancer screening in Taizhou, China. Ageing well with tech: Exploring the determinants of e-healthcare services adoption in an emerging economy. Chinese colposcopists' attitudes toward the colposcopic artificial intelligence auxiliary diagnostic system (CAIADS): A nation-wide, multi-center survey. Digital leadership: Norwegian healthcare managers' attitudes towards using digital tools. Disease characteristics influence the privacy calculus to adopt electronic health records: A survey study in Germany.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1