在骨盆骨折固定中测量逆行椎弓根上螺钉走廊的可靠自动方法

IF 4.4 1区 医学 Q1 ORTHOPEDICS Journal of Bone and Joint Surgery, American Volume Pub Date : 2024-08-09 DOI:10.2106/JBJS.23.00695
Jing-Xin Zhao, Hua Chen, Mingjie Dong, Fujiao Ju, Houchen Lyu, Li-Cheng Zhang, Pei-Fu Tang
{"title":"在骨盆骨折固定中测量逆行椎弓根上螺钉走廊的可靠自动方法","authors":"Jing-Xin Zhao, Hua Chen, Mingjie Dong, Fujiao Ju, Houchen Lyu, Li-Cheng Zhang, Pei-Fu Tang","doi":"10.2106/JBJS.23.00695","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Precise measurement of the intraosseous corridor within the superior pubic ramus is essential for the accurate percutaneous placement of a retrograde superior ramus screw (SRS). However, conventional manual measurement methods are often subjective, leading to variations in results among observers. Our goal was to develop an automated and dependable method for determining the retrograde SRS corridor.</p><p><strong>Methods: </strong>We developed an automated technique that utilized a computed tomography (CT) image-based search algorithm to identify the retrograde SRS corridor with the maximum diameter. We evaluated the reliability of this automated approach in comparison to a manual method using 17 pelves. Subsequently, we used both methods to measure the diameter, length, and orientation of the retrograde SRS corridor in 204 pelves in a Chinese population and assessed the intra- and interobserver agreement of each method by calculating the root-mean-square error (RMSE) and constructing Bland-Altman plots. We determined the screw applicability (percentages of hemipelves that could be treated with specific sizes of screws) for each method. Additionally, we investigated potential factors influencing the corridor, such as sex, age, height, and weight, through regression analysis.</p><p><strong>Results: </strong>The intra- and interobserver intraclass correlation coefficients (ICCs) for the automated method (0.998 and 0.995) were higher than those for the manual approach (0.925 and 0.918) in the assessment of the corridor diameter. Furthermore, the diameter identified by the automated method was notably larger than the diameter measured with the manual method, with a mean difference and RMSE of 0.9 mm and 1.1 mm, respectively. The automated method revealed a significantly smaller corridor diameter in females than in males (an average of 7.5 and 10.4 mm, respectively). Moreover, use of the automated method allowed 80.6% of the females to be managed with a 4.5-mm screw while a 6.5-mm screw could be utilized in 19.4%, surpassing the capabilities of the manual method. Female sex had the most substantial impact on corridor diameter (β = -0.583).</p><p><strong>Conclusions: </strong>The automated method exhibited better reliability than the manual method in measuring the retrograde SRS corridor, and showed a larger corridor diameter for screw placement. Females had a significantly smaller corridor diameter than males. Given the intricate nature of the automated approach, which entails utilizing different software and interactive procedures, our current method is not readily applicable for traumatologists. We are working on developing integrated software with the goal of providing a more user-friendly solution for traumatologists in the near future.</p><p><strong>Level of evidence: </strong>Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.</p>","PeriodicalId":15273,"journal":{"name":"Journal of Bone and Joint Surgery, American Volume","volume":" ","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dependable Automated Approach for Measuring the Retrograde Superior Ramus Screw Corridor in Pelvic Fracture Fixation.\",\"authors\":\"Jing-Xin Zhao, Hua Chen, Mingjie Dong, Fujiao Ju, Houchen Lyu, Li-Cheng Zhang, Pei-Fu Tang\",\"doi\":\"10.2106/JBJS.23.00695\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Precise measurement of the intraosseous corridor within the superior pubic ramus is essential for the accurate percutaneous placement of a retrograde superior ramus screw (SRS). However, conventional manual measurement methods are often subjective, leading to variations in results among observers. Our goal was to develop an automated and dependable method for determining the retrograde SRS corridor.</p><p><strong>Methods: </strong>We developed an automated technique that utilized a computed tomography (CT) image-based search algorithm to identify the retrograde SRS corridor with the maximum diameter. We evaluated the reliability of this automated approach in comparison to a manual method using 17 pelves. Subsequently, we used both methods to measure the diameter, length, and orientation of the retrograde SRS corridor in 204 pelves in a Chinese population and assessed the intra- and interobserver agreement of each method by calculating the root-mean-square error (RMSE) and constructing Bland-Altman plots. We determined the screw applicability (percentages of hemipelves that could be treated with specific sizes of screws) for each method. Additionally, we investigated potential factors influencing the corridor, such as sex, age, height, and weight, through regression analysis.</p><p><strong>Results: </strong>The intra- and interobserver intraclass correlation coefficients (ICCs) for the automated method (0.998 and 0.995) were higher than those for the manual approach (0.925 and 0.918) in the assessment of the corridor diameter. Furthermore, the diameter identified by the automated method was notably larger than the diameter measured with the manual method, with a mean difference and RMSE of 0.9 mm and 1.1 mm, respectively. The automated method revealed a significantly smaller corridor diameter in females than in males (an average of 7.5 and 10.4 mm, respectively). Moreover, use of the automated method allowed 80.6% of the females to be managed with a 4.5-mm screw while a 6.5-mm screw could be utilized in 19.4%, surpassing the capabilities of the manual method. Female sex had the most substantial impact on corridor diameter (β = -0.583).</p><p><strong>Conclusions: </strong>The automated method exhibited better reliability than the manual method in measuring the retrograde SRS corridor, and showed a larger corridor diameter for screw placement. Females had a significantly smaller corridor diameter than males. Given the intricate nature of the automated approach, which entails utilizing different software and interactive procedures, our current method is not readily applicable for traumatologists. We are working on developing integrated software with the goal of providing a more user-friendly solution for traumatologists in the near future.</p><p><strong>Level of evidence: </strong>Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.</p>\",\"PeriodicalId\":15273,\"journal\":{\"name\":\"Journal of Bone and Joint Surgery, American Volume\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":4.4000,\"publicationDate\":\"2024-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Bone and Joint Surgery, American Volume\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2106/JBJS.23.00695\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Bone and Joint Surgery, American Volume","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2106/JBJS.23.00695","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:精确测量耻骨上嵴内的骨内走廊对于经皮准确放置逆行上嵴螺钉(SRS)至关重要。然而,传统的手动测量方法往往比较主观,导致观察者之间的结果存在差异。我们的目标是开发一种自动、可靠的方法来确定逆行 SRS 走廊:我们开发了一种自动化技术,利用基于计算机断层扫描(CT)图像的搜索算法来确定最大直径的逆行 SRS 走廊。我们使用 17 个皮瓣对这种自动方法与手动方法的可靠性进行了比较评估。随后,我们使用这两种方法测量了中国人群中204个pelves的逆行SRS走廊的直径、长度和方向,并通过计算均方根误差(RMSE)和构建Bland-Altman图评估了每种方法的观察者内部和观察者之间的一致性。我们确定了每种方法的螺钉适用性(可使用特定尺寸螺钉治疗的半侧髋关节百分比)。此外,我们还通过回归分析调查了影响走廊的潜在因素,如性别、年龄、身高和体重:结果:在评估走廊直径时,自动方法的观察者内部和观察者之间的类内相关系数(ICCs)(0.998 和 0.995)高于手动方法(0.925 和 0.918)。此外,自动方法识别的直径明显大于人工方法测量的直径,平均差和均方误差分别为 0.9 毫米和 1.1 毫米。自动方法显示的女性走廊直径明显小于男性(平均值分别为 7.5 毫米和 10.4 毫米)。此外,使用自动方法,80.6%的女性可以使用 4.5 毫米的螺钉,19.4%的女性可以使用 6.5 毫米的螺钉,超过了手动方法的能力。女性性别对走廊直径的影响最大(β = -0.583):结论:在测量逆行 SRS 通道时,自动方法比手动方法显示出更好的可靠性,并且在螺钉置入时显示出更大的通道直径。女性的走廊直径明显小于男性。鉴于自动方法的复杂性,需要使用不同的软件和互动程序,我们目前的方法并不适用于创伤科医生。我们正在开发集成软件,目标是在不久的将来为创伤学家提供更方便的解决方案:诊断级别 III。有关证据级别的完整描述,请参阅 "作者须知"。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dependable Automated Approach for Measuring the Retrograde Superior Ramus Screw Corridor in Pelvic Fracture Fixation.

Background: Precise measurement of the intraosseous corridor within the superior pubic ramus is essential for the accurate percutaneous placement of a retrograde superior ramus screw (SRS). However, conventional manual measurement methods are often subjective, leading to variations in results among observers. Our goal was to develop an automated and dependable method for determining the retrograde SRS corridor.

Methods: We developed an automated technique that utilized a computed tomography (CT) image-based search algorithm to identify the retrograde SRS corridor with the maximum diameter. We evaluated the reliability of this automated approach in comparison to a manual method using 17 pelves. Subsequently, we used both methods to measure the diameter, length, and orientation of the retrograde SRS corridor in 204 pelves in a Chinese population and assessed the intra- and interobserver agreement of each method by calculating the root-mean-square error (RMSE) and constructing Bland-Altman plots. We determined the screw applicability (percentages of hemipelves that could be treated with specific sizes of screws) for each method. Additionally, we investigated potential factors influencing the corridor, such as sex, age, height, and weight, through regression analysis.

Results: The intra- and interobserver intraclass correlation coefficients (ICCs) for the automated method (0.998 and 0.995) were higher than those for the manual approach (0.925 and 0.918) in the assessment of the corridor diameter. Furthermore, the diameter identified by the automated method was notably larger than the diameter measured with the manual method, with a mean difference and RMSE of 0.9 mm and 1.1 mm, respectively. The automated method revealed a significantly smaller corridor diameter in females than in males (an average of 7.5 and 10.4 mm, respectively). Moreover, use of the automated method allowed 80.6% of the females to be managed with a 4.5-mm screw while a 6.5-mm screw could be utilized in 19.4%, surpassing the capabilities of the manual method. Female sex had the most substantial impact on corridor diameter (β = -0.583).

Conclusions: The automated method exhibited better reliability than the manual method in measuring the retrograde SRS corridor, and showed a larger corridor diameter for screw placement. Females had a significantly smaller corridor diameter than males. Given the intricate nature of the automated approach, which entails utilizing different software and interactive procedures, our current method is not readily applicable for traumatologists. We are working on developing integrated software with the goal of providing a more user-friendly solution for traumatologists in the near future.

Level of evidence: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.90
自引率
7.50%
发文量
660
审稿时长
1 months
期刊介绍: The Journal of Bone & Joint Surgery (JBJS) has been the most valued source of information for orthopaedic surgeons and researchers for over 125 years and is the gold standard in peer-reviewed scientific information in the field. A core journal and essential reading for general as well as specialist orthopaedic surgeons worldwide, The Journal publishes evidence-based research to enhance the quality of care for orthopaedic patients. Standards of excellence and high quality are maintained in everything we do, from the science of the content published to the customer service we provide. JBJS is an independent, non-profit journal.
期刊最新文献
Blood and Bone-Derived DNA Methylation Ages Predict Mortality After Geriatric Hip Fracture: A Pilot Study. Development and Validation of Objective and Subjective Osteoporosis Knowledge Instruments Among Chinese Orthopaedic Surgeons. Radiographic Outcome Following Treatment of Residual Hip Dysplasia with Pemberton Versus Salter Osteotomy: Comparison of Results in Patients Followed to Skeletal Maturity. What's Important (Arts & Humanities): Temple of Healing. What's Important: Let's Learn to Talk About Our Patients as if They Are Sitting Right in Front of Us.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1