应用患者专用器械对儿童拇趾外翻畸形进行阶梯截骨术:初步报告。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-10-01 Epub Date: 2024-08-10 DOI:10.1007/s00264-024-06268-4
An Yan, Xiaoqian Tan, Qian Tan, Weihua Ye, Jiangyan Wu, Haibo Mei, Guanghui Zhu, Han Xiao
{"title":"应用患者专用器械对儿童拇趾外翻畸形进行阶梯截骨术:初步报告。","authors":"An Yan, Xiaoqian Tan, Qian Tan, Weihua Ye, Jiangyan Wu, Haibo Mei, Guanghui Zhu, Han Xiao","doi":"10.1007/s00264-024-06268-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The step-cut osteotomy has been recognized as a valuable approach for addressing cubitus varus deformity, albeit one that necessitates technical proficiency. This study aims to evaluate the efficacy of the modified step-cut osteotomy technique in conjunction with patient-specific instruments by clinical and radiological assessment.</p><p><strong>Methods: </strong>We conducted a retrospective review of patients who underwent modified step-cut osteotomy with the use of patient-specific instruments in conjunction with Kirschner wires fixation for the correction of cubitus varus deformity between April 2016 and April 2022. Follow-up was performed for a minimum of two years, during which pre-operative and post-operative clinical and radiological parameters were compared.</p><p><strong>Results: </strong>Fifteen patients were enrolled in this study. The mean pre-operative humeral-elbow-wrist (HEW) of the affected side was -21.7° (ranging from -14° to -34°), while the normal side was 9.4° (ranging from 5° to 15°). The post-operation HEW of affected side was 9° (ranging from 4° to 16°). There was no significant difference between the normal side and affected side after operation (p = 0.74). Pre-operative range of motion in the affected side was 130°, while the post-operative range of motion was 132°. Fourteen patients (93.3%) were pleased with the overall appearance of their elbow. None lazy-S deformity was observed in these cases. There were no major complications.</p><p><strong>Conclusion: </strong>The modified step-cut osteotomy technique, utilizing patient-specific instrument in conjunction with Kirschner wires fixation was found to be a safe, reliable, and technically easy procedure for correcting cubitus varus deformity.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Step-cut osteotomy for cubitus varus deformity with application of patient-specific instrument in children: a preliminary report.\",\"authors\":\"An Yan, Xiaoqian Tan, Qian Tan, Weihua Ye, Jiangyan Wu, Haibo Mei, Guanghui Zhu, Han Xiao\",\"doi\":\"10.1007/s00264-024-06268-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The step-cut osteotomy has been recognized as a valuable approach for addressing cubitus varus deformity, albeit one that necessitates technical proficiency. This study aims to evaluate the efficacy of the modified step-cut osteotomy technique in conjunction with patient-specific instruments by clinical and radiological assessment.</p><p><strong>Methods: </strong>We conducted a retrospective review of patients who underwent modified step-cut osteotomy with the use of patient-specific instruments in conjunction with Kirschner wires fixation for the correction of cubitus varus deformity between April 2016 and April 2022. Follow-up was performed for a minimum of two years, during which pre-operative and post-operative clinical and radiological parameters were compared.</p><p><strong>Results: </strong>Fifteen patients were enrolled in this study. The mean pre-operative humeral-elbow-wrist (HEW) of the affected side was -21.7° (ranging from -14° to -34°), while the normal side was 9.4° (ranging from 5° to 15°). The post-operation HEW of affected side was 9° (ranging from 4° to 16°). There was no significant difference between the normal side and affected side after operation (p = 0.74). Pre-operative range of motion in the affected side was 130°, while the post-operative range of motion was 132°. Fourteen patients (93.3%) were pleased with the overall appearance of their elbow. None lazy-S deformity was observed in these cases. There were no major complications.</p><p><strong>Conclusion: </strong>The modified step-cut osteotomy technique, utilizing patient-specific instrument in conjunction with Kirschner wires fixation was found to be a safe, reliable, and technically easy procedure for correcting cubitus varus deformity.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00264-024-06268-4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/10 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00264-024-06268-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/10 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

目的:阶梯截骨术已被公认为是治疗拇趾外翻畸形的重要方法,但需要熟练的技术。本研究旨在通过临床和放射学评估,评估改良阶梯截骨技术与患者特定器械相结合的疗效:我们对2016年4月至2022年4月期间接受改良阶梯截骨术的患者进行了回顾性研究,这些患者使用患者特异性器械结合Kirschner钢丝固定术矫正了拇趾外翻畸形。随访至少两年,在此期间比较术前和术后的临床和放射学参数:本研究共纳入了 15 名患者。术前患侧肱骨-肘-腕(HEW)的平均值为-21.7°(从-14°到-34°不等),而正常侧为9.4°(从5°到15°不等)。手术后患侧的 HEW 为 9°(介于 4°至 16°之间)。术后正常一侧和患侧无明显差异(P = 0.74)。术前患侧的活动范围为 130°,术后为 132°。14名患者(93.3%)对肘部的整体外观表示满意。在这些病例中,没有发现任何懒惰畸形。结论结论:改良的阶梯切割截骨术是一种安全、可靠、技术简单的矫正肘关节畸形的手术,它采用了患者专用的器械和Kirschner钢丝固定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Step-cut osteotomy for cubitus varus deformity with application of patient-specific instrument in children: a preliminary report.

Purpose: The step-cut osteotomy has been recognized as a valuable approach for addressing cubitus varus deformity, albeit one that necessitates technical proficiency. This study aims to evaluate the efficacy of the modified step-cut osteotomy technique in conjunction with patient-specific instruments by clinical and radiological assessment.

Methods: We conducted a retrospective review of patients who underwent modified step-cut osteotomy with the use of patient-specific instruments in conjunction with Kirschner wires fixation for the correction of cubitus varus deformity between April 2016 and April 2022. Follow-up was performed for a minimum of two years, during which pre-operative and post-operative clinical and radiological parameters were compared.

Results: Fifteen patients were enrolled in this study. The mean pre-operative humeral-elbow-wrist (HEW) of the affected side was -21.7° (ranging from -14° to -34°), while the normal side was 9.4° (ranging from 5° to 15°). The post-operation HEW of affected side was 9° (ranging from 4° to 16°). There was no significant difference between the normal side and affected side after operation (p = 0.74). Pre-operative range of motion in the affected side was 130°, while the post-operative range of motion was 132°. Fourteen patients (93.3%) were pleased with the overall appearance of their elbow. None lazy-S deformity was observed in these cases. There were no major complications.

Conclusion: The modified step-cut osteotomy technique, utilizing patient-specific instrument in conjunction with Kirschner wires fixation was found to be a safe, reliable, and technically easy procedure for correcting cubitus varus deformity.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1