Baoxin Zhang, Wanxiong He, Hao Wu, Ting Hao, Xiaolong Yang, Jie Cheng, Chao Ma, Guanghui Liu, Jianzhong Wang
{"title":"使用新型肱骨前远端解剖锁定钢板治疗成人肱骨髁上骨折:病例报告。","authors":"Baoxin Zhang, Wanxiong He, Hao Wu, Ting Hao, Xiaolong Yang, Jie Cheng, Chao Ma, Guanghui Liu, Jianzhong Wang","doi":"10.1186/s13256-024-04700-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Due to its unique anatomical characteristics, supracondylar fractures of the humerus are often difficult to achieve firm fixation with internal fixation equipment, resulting in delayed functional exercise, often leaving cubitus varus deformity, elbow stiffness, contractures, and other complications. Here, we report an adult patient with a supracondylar fracture of the humerus who underwent internal fixation through an anterior median incision in the humerus with our self-developed anterior anatomical locking plate of the distal humerus.</p><p><strong>Case presentation: </strong>A 29-year-old male patient of Chinese ethnicity with trauma-induced right supracondylar fracture of the humerus and multiple soft tissue contusions, without nerve damage, blood vessel damage, or other injuries, underwent an internal incision in our hospital using a new anatomical locking plate for the anterior distal humerus fixed treatment. During the 16-month follow-up period, the patient's elbow range of motion was almost completely restored, functional scores were excellent, and there were no minor or major postoperative complications.</p><p><strong>Conclusion: </strong>In this study, we propose a surgical reconstruction strategy for adult patients with supracondylar humeral fractures. Through the anterior median incision of the humerus, open reduction and internal fixation were performed with an anatomic locking plate on the anterior side of the distal humerus to restore and fix the structure of the distal humerus, and satisfactory clinical results were achieved in our case.</p>","PeriodicalId":16236,"journal":{"name":"Journal of Medical Case Reports","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11316439/pdf/","citationCount":"0","resultStr":"{\"title\":\"Treatment of supracondylar fractures of the humerus in adults using a novel anatomical locking plate on the anterior distal humerus: a case report.\",\"authors\":\"Baoxin Zhang, Wanxiong He, Hao Wu, Ting Hao, Xiaolong Yang, Jie Cheng, Chao Ma, Guanghui Liu, Jianzhong Wang\",\"doi\":\"10.1186/s13256-024-04700-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Due to its unique anatomical characteristics, supracondylar fractures of the humerus are often difficult to achieve firm fixation with internal fixation equipment, resulting in delayed functional exercise, often leaving cubitus varus deformity, elbow stiffness, contractures, and other complications. Here, we report an adult patient with a supracondylar fracture of the humerus who underwent internal fixation through an anterior median incision in the humerus with our self-developed anterior anatomical locking plate of the distal humerus.</p><p><strong>Case presentation: </strong>A 29-year-old male patient of Chinese ethnicity with trauma-induced right supracondylar fracture of the humerus and multiple soft tissue contusions, without nerve damage, blood vessel damage, or other injuries, underwent an internal incision in our hospital using a new anatomical locking plate for the anterior distal humerus fixed treatment. During the 16-month follow-up period, the patient's elbow range of motion was almost completely restored, functional scores were excellent, and there were no minor or major postoperative complications.</p><p><strong>Conclusion: </strong>In this study, we propose a surgical reconstruction strategy for adult patients with supracondylar humeral fractures. Through the anterior median incision of the humerus, open reduction and internal fixation were performed with an anatomic locking plate on the anterior side of the distal humerus to restore and fix the structure of the distal humerus, and satisfactory clinical results were achieved in our case.</p>\",\"PeriodicalId\":16236,\"journal\":{\"name\":\"Journal of Medical Case Reports\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2024-08-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11316439/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s13256-024-04700-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13256-024-04700-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
Treatment of supracondylar fractures of the humerus in adults using a novel anatomical locking plate on the anterior distal humerus: a case report.
Background: Due to its unique anatomical characteristics, supracondylar fractures of the humerus are often difficult to achieve firm fixation with internal fixation equipment, resulting in delayed functional exercise, often leaving cubitus varus deformity, elbow stiffness, contractures, and other complications. Here, we report an adult patient with a supracondylar fracture of the humerus who underwent internal fixation through an anterior median incision in the humerus with our self-developed anterior anatomical locking plate of the distal humerus.
Case presentation: A 29-year-old male patient of Chinese ethnicity with trauma-induced right supracondylar fracture of the humerus and multiple soft tissue contusions, without nerve damage, blood vessel damage, or other injuries, underwent an internal incision in our hospital using a new anatomical locking plate for the anterior distal humerus fixed treatment. During the 16-month follow-up period, the patient's elbow range of motion was almost completely restored, functional scores were excellent, and there were no minor or major postoperative complications.
Conclusion: In this study, we propose a surgical reconstruction strategy for adult patients with supracondylar humeral fractures. Through the anterior median incision of the humerus, open reduction and internal fixation were performed with an anatomic locking plate on the anterior side of the distal humerus to restore and fix the structure of the distal humerus, and satisfactory clinical results were achieved in our case.
期刊介绍:
JMCR is an open access, peer-reviewed online journal that will consider any original case report that expands the field of general medical knowledge. Reports should show one of the following: 1. Unreported or unusual side effects or adverse interactions involving medications 2. Unexpected or unusual presentations of a disease 3. New associations or variations in disease processes 4. Presentations, diagnoses and/or management of new and emerging diseases 5. An unexpected association between diseases or symptoms 6. An unexpected event in the course of observing or treating a patient 7. Findings that shed new light on the possible pathogenesis of a disease or an adverse effect