{"title":"机器人辅助手术方法治疗正中弓形韧带综合征的可行性和安全性--系统综述。","authors":"Mallikarjun Gunjiganvi, Srikanth Marthandam, Rajeswari Murugesan, Raj Palaniappan","doi":"10.1007/s11701-024-02067-6","DOIUrl":null,"url":null,"abstract":"<p><p>Median arcuate ligament syndrome (MALS) is rare syndrome and is diagnosis of exclusion. Though first robotic median arcuate ligament release (MALR) was described in 2007, there are only a few case reports (CR), case series (CS), and retrospective cohort studies (RCS) in the published literature. The purpose of this study was to assess the feasibility and safety of robotic-assisted MALR (r-MALR). PubMed, Embase, and Cochrane databases were searched (last search December 2023) for articles reporting r-MALR. All studies including CR, CS, RCS reporting technical feasibility (operating time and rate of conversions), safety (intra-operative complications, blood loss, post-operative complications), and outcome (length of stay [LoS]) were included (PROSPERO: CRD42024502792). A total of 23 studies (8-CR, 5-CS, 10-RCS) with total 290 patients were available in the literature. Except 1-RCS, all studies reported age and mean age for CR was 40.38 ± 17.7, 36.08 ± 15.12 for CS, 39.72 ± 7.35 years for RS; except 2-RCS, all studies reported gender distribution and there were 57 males and 214 females. Operating time: 3-CR, 4-CS, 9-RCS reported operating time, and mean time was 111 ± 54, 131.69 ± 7.51, 117.34 ± 35.03 min, respectively. Conversion rate: All studies reported data on conversion and only four (1.37%) cases were converted-one to laparoscopic approach, three to open approach (1-inadvertent celiac arteriotomy, 2-reasons not mentioned). Intraoperative complications: only 5-CR, 4-CS, and 9-RCS reported data on intra-operative complications, and there were only 6 complications (1.5%): 1-inadvertent celiac arteriotomy converted to open; 3-unnamed vascular injuries (2 managed robotically, 1 converted to open); 1-bleeding managed robotically; there were no other reported injuries. Estimated blood loss ranged from 5 to 30 ml. Post-operative complications: 5-CR, 4-CS, 8-RCS described post-operative complications in 21 (7%) patients. Twenty cases were grade I, one was grade IIIa, and all managed successfully. LoS stay: 2-CR, 4-CS, 10-RCS reported LoS and overall, it was 2 days. r-MALR is reasonable, technically feasible, safe, and has acceptable outcomes. In addition, robotic approach provided superior vision, improved dexterity, precise, and easy circumferential dissection.PROSPERO registration: The protocol was registered in the PROSPERO database (CRD42024502792).</p>","PeriodicalId":47616,"journal":{"name":"Journal of Robotic Surgery","volume":"18 1","pages":"318"},"PeriodicalIF":2.2000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Feasibility and safety of robotic-assisted surgical approach in median arcuate ligament syndrome-a systematic review.\",\"authors\":\"Mallikarjun Gunjiganvi, Srikanth Marthandam, Rajeswari Murugesan, Raj Palaniappan\",\"doi\":\"10.1007/s11701-024-02067-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Median arcuate ligament syndrome (MALS) is rare syndrome and is diagnosis of exclusion. Though first robotic median arcuate ligament release (MALR) was described in 2007, there are only a few case reports (CR), case series (CS), and retrospective cohort studies (RCS) in the published literature. The purpose of this study was to assess the feasibility and safety of robotic-assisted MALR (r-MALR). PubMed, Embase, and Cochrane databases were searched (last search December 2023) for articles reporting r-MALR. All studies including CR, CS, RCS reporting technical feasibility (operating time and rate of conversions), safety (intra-operative complications, blood loss, post-operative complications), and outcome (length of stay [LoS]) were included (PROSPERO: CRD42024502792). A total of 23 studies (8-CR, 5-CS, 10-RCS) with total 290 patients were available in the literature. Except 1-RCS, all studies reported age and mean age for CR was 40.38 ± 17.7, 36.08 ± 15.12 for CS, 39.72 ± 7.35 years for RS; except 2-RCS, all studies reported gender distribution and there were 57 males and 214 females. Operating time: 3-CR, 4-CS, 9-RCS reported operating time, and mean time was 111 ± 54, 131.69 ± 7.51, 117.34 ± 35.03 min, respectively. Conversion rate: All studies reported data on conversion and only four (1.37%) cases were converted-one to laparoscopic approach, three to open approach (1-inadvertent celiac arteriotomy, 2-reasons not mentioned). Intraoperative complications: only 5-CR, 4-CS, and 9-RCS reported data on intra-operative complications, and there were only 6 complications (1.5%): 1-inadvertent celiac arteriotomy converted to open; 3-unnamed vascular injuries (2 managed robotically, 1 converted to open); 1-bleeding managed robotically; there were no other reported injuries. Estimated blood loss ranged from 5 to 30 ml. Post-operative complications: 5-CR, 4-CS, 8-RCS described post-operative complications in 21 (7%) patients. Twenty cases were grade I, one was grade IIIa, and all managed successfully. LoS stay: 2-CR, 4-CS, 10-RCS reported LoS and overall, it was 2 days. r-MALR is reasonable, technically feasible, safe, and has acceptable outcomes. In addition, robotic approach provided superior vision, improved dexterity, precise, and easy circumferential dissection.PROSPERO registration: The protocol was registered in the PROSPERO database (CRD42024502792).</p>\",\"PeriodicalId\":47616,\"journal\":{\"name\":\"Journal of Robotic Surgery\",\"volume\":\"18 1\",\"pages\":\"318\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Robotic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11701-024-02067-6\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Robotic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11701-024-02067-6","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
Feasibility and safety of robotic-assisted surgical approach in median arcuate ligament syndrome-a systematic review.
Median arcuate ligament syndrome (MALS) is rare syndrome and is diagnosis of exclusion. Though first robotic median arcuate ligament release (MALR) was described in 2007, there are only a few case reports (CR), case series (CS), and retrospective cohort studies (RCS) in the published literature. The purpose of this study was to assess the feasibility and safety of robotic-assisted MALR (r-MALR). PubMed, Embase, and Cochrane databases were searched (last search December 2023) for articles reporting r-MALR. All studies including CR, CS, RCS reporting technical feasibility (operating time and rate of conversions), safety (intra-operative complications, blood loss, post-operative complications), and outcome (length of stay [LoS]) were included (PROSPERO: CRD42024502792). A total of 23 studies (8-CR, 5-CS, 10-RCS) with total 290 patients were available in the literature. Except 1-RCS, all studies reported age and mean age for CR was 40.38 ± 17.7, 36.08 ± 15.12 for CS, 39.72 ± 7.35 years for RS; except 2-RCS, all studies reported gender distribution and there were 57 males and 214 females. Operating time: 3-CR, 4-CS, 9-RCS reported operating time, and mean time was 111 ± 54, 131.69 ± 7.51, 117.34 ± 35.03 min, respectively. Conversion rate: All studies reported data on conversion and only four (1.37%) cases were converted-one to laparoscopic approach, three to open approach (1-inadvertent celiac arteriotomy, 2-reasons not mentioned). Intraoperative complications: only 5-CR, 4-CS, and 9-RCS reported data on intra-operative complications, and there were only 6 complications (1.5%): 1-inadvertent celiac arteriotomy converted to open; 3-unnamed vascular injuries (2 managed robotically, 1 converted to open); 1-bleeding managed robotically; there were no other reported injuries. Estimated blood loss ranged from 5 to 30 ml. Post-operative complications: 5-CR, 4-CS, 8-RCS described post-operative complications in 21 (7%) patients. Twenty cases were grade I, one was grade IIIa, and all managed successfully. LoS stay: 2-CR, 4-CS, 10-RCS reported LoS and overall, it was 2 days. r-MALR is reasonable, technically feasible, safe, and has acceptable outcomes. In addition, robotic approach provided superior vision, improved dexterity, precise, and easy circumferential dissection.PROSPERO registration: The protocol was registered in the PROSPERO database (CRD42024502792).
期刊介绍:
The aim of the Journal of Robotic Surgery is to become the leading worldwide journal for publication of articles related to robotic surgery, encompassing surgical simulation and integrated imaging techniques. The journal provides a centralized, focused resource for physicians wishing to publish their experience or those wishing to avail themselves of the most up-to-date findings.The journal reports on advance in a wide range of surgical specialties including adult and pediatric urology, general surgery, cardiac surgery, gynecology, ENT, orthopedics and neurosurgery.The use of robotics in surgery is broad-based and will undoubtedly expand over the next decade as new technical innovations and techniques increase the applicability of its use. The journal intends to capture this trend as it develops.