{"title":"树脂复合材料半透明度与 IOS 精确度的相关性:体外研究","authors":"Nam-Cong-Nhat Huynh, Anh-Thi-Van Tran, Thu-Nguyen-Trang Truong, Yen-Thi Le, Nguyen-Chi Tran, Trang-Thi-Ngoc Tran, Ding-Han Wang, Ming-Lun Hsu","doi":"10.4317/jced.61620","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Different restoration materials have different optical characteristics that influence the intraoral scanner's (IOS) image accuracy. The purpose of this <i>in-vitro</i> investigation was to investigate how composite translucency affected the accuracy of IOS.</p><p><strong>Material and methods: </strong>GC G-aenial Universal Injectable JE composite plates were used for the study at 3 thicknesses (1-2-3mm). A lab scanner (3Shape E1) obtained 1 reference scan, whereas IOS (Trios3) was used to conduct 10 experimental scans per group. After 3D superimposition, deviation values were used to assess the accuracy (trueness and precision) outcomes for the corresponding groups. Using an LS170 V2.0 colorimeter, the translucency parameter (TP) of the plates was determined from L*a*b* values of CIELAB color space.</p><p><strong>Results: </strong>The composite translucency resulted in a decrease in the scale of digital impressions. The 1mm group had the largest scale reduction (0.02mm) significantly, followed by the 2mm and 3mm groups (0.01mm). No difference was found in mean precision. The colorimeter detects the L*a*b* values and showed that 1mm composite plate expressed the highest TP value, then 2mm and 3mm groups (28.90, 14.26 and 6.49 respectively). The thinner composite, the higher translucency and TP were highly positively correlated to IOS trueness of composite plates.</p><p><strong>Conclusions: </strong>Composite translucency has an impact on optical impression accuracy. In correlation, the optical impression becomes less accurate the more translucent the composite is. This implies that in the digital process, the dentist should specify the appropriate optical properties of composite materials concerning both their mechanical and aesthetic qualities. <b>Key words:</b>Accuracy, translucency, resin composite, digital dentistry, intraoral-scanner.</p>","PeriodicalId":15376,"journal":{"name":"Journal of Clinical and Experimental Dentistry","volume":"16 6","pages":"e678-e684"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310982/pdf/","citationCount":"0","resultStr":"{\"title\":\"Correlation of resin composite translucency and IOS accuracy: An <i>in-vitro</i> study.\",\"authors\":\"Nam-Cong-Nhat Huynh, Anh-Thi-Van Tran, Thu-Nguyen-Trang Truong, Yen-Thi Le, Nguyen-Chi Tran, Trang-Thi-Ngoc Tran, Ding-Han Wang, Ming-Lun Hsu\",\"doi\":\"10.4317/jced.61620\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Different restoration materials have different optical characteristics that influence the intraoral scanner's (IOS) image accuracy. The purpose of this <i>in-vitro</i> investigation was to investigate how composite translucency affected the accuracy of IOS.</p><p><strong>Material and methods: </strong>GC G-aenial Universal Injectable JE composite plates were used for the study at 3 thicknesses (1-2-3mm). A lab scanner (3Shape E1) obtained 1 reference scan, whereas IOS (Trios3) was used to conduct 10 experimental scans per group. After 3D superimposition, deviation values were used to assess the accuracy (trueness and precision) outcomes for the corresponding groups. Using an LS170 V2.0 colorimeter, the translucency parameter (TP) of the plates was determined from L*a*b* values of CIELAB color space.</p><p><strong>Results: </strong>The composite translucency resulted in a decrease in the scale of digital impressions. The 1mm group had the largest scale reduction (0.02mm) significantly, followed by the 2mm and 3mm groups (0.01mm). No difference was found in mean precision. The colorimeter detects the L*a*b* values and showed that 1mm composite plate expressed the highest TP value, then 2mm and 3mm groups (28.90, 14.26 and 6.49 respectively). The thinner composite, the higher translucency and TP were highly positively correlated to IOS trueness of composite plates.</p><p><strong>Conclusions: </strong>Composite translucency has an impact on optical impression accuracy. In correlation, the optical impression becomes less accurate the more translucent the composite is. This implies that in the digital process, the dentist should specify the appropriate optical properties of composite materials concerning both their mechanical and aesthetic qualities. <b>Key words:</b>Accuracy, translucency, resin composite, digital dentistry, intraoral-scanner.</p>\",\"PeriodicalId\":15376,\"journal\":{\"name\":\"Journal of Clinical and Experimental Dentistry\",\"volume\":\"16 6\",\"pages\":\"e678-e684\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310982/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical and Experimental Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4317/jced.61620\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical and Experimental Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4317/jced.61620","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
Correlation of resin composite translucency and IOS accuracy: An in-vitro study.
Background: Different restoration materials have different optical characteristics that influence the intraoral scanner's (IOS) image accuracy. The purpose of this in-vitro investigation was to investigate how composite translucency affected the accuracy of IOS.
Material and methods: GC G-aenial Universal Injectable JE composite plates were used for the study at 3 thicknesses (1-2-3mm). A lab scanner (3Shape E1) obtained 1 reference scan, whereas IOS (Trios3) was used to conduct 10 experimental scans per group. After 3D superimposition, deviation values were used to assess the accuracy (trueness and precision) outcomes for the corresponding groups. Using an LS170 V2.0 colorimeter, the translucency parameter (TP) of the plates was determined from L*a*b* values of CIELAB color space.
Results: The composite translucency resulted in a decrease in the scale of digital impressions. The 1mm group had the largest scale reduction (0.02mm) significantly, followed by the 2mm and 3mm groups (0.01mm). No difference was found in mean precision. The colorimeter detects the L*a*b* values and showed that 1mm composite plate expressed the highest TP value, then 2mm and 3mm groups (28.90, 14.26 and 6.49 respectively). The thinner composite, the higher translucency and TP were highly positively correlated to IOS trueness of composite plates.
Conclusions: Composite translucency has an impact on optical impression accuracy. In correlation, the optical impression becomes less accurate the more translucent the composite is. This implies that in the digital process, the dentist should specify the appropriate optical properties of composite materials concerning both their mechanical and aesthetic qualities. Key words:Accuracy, translucency, resin composite, digital dentistry, intraoral-scanner.
期刊介绍:
Indexed in PUBMED, PubMed Central® (PMC) since 2012 and SCOPUSJournal of Clinical and Experimental Dentistry is an Open Access (free access on-line) - http://www.medicinaoral.com/odo/indice.htm. The aim of the Journal of Clinical and Experimental Dentistry is: - Periodontology - Community and Preventive Dentistry - Esthetic Dentistry - Biomaterials and Bioengineering in Dentistry - Operative Dentistry and Endodontics - Prosthetic Dentistry - Orthodontics - Oral Medicine and Pathology - Odontostomatology for the disabled or special patients - Oral Surgery