{"title":"用 Ribbond 纤维提高 MOD 修复体的断裂强度。","authors":"Francesca Zotti, Francesca Ferrari, Corrado Paganelli, Francesca Pilati, Giorgia Lanzaretti, Daniele Arlacchi, Nicoletta Zerman","doi":"10.4317/jced.61608","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The aim of this study was to compare the fracture strength of two different Ribbond Fiber (Ribbond, Ribbond Inc., Seattle, WA, USA) restoration strategies in 5 mm deep standardized MOD cavities without interaxial dentin.</p><p><strong>Material and methods: </strong>34 extracted human molars were randomly divided into two groups and restored as follows: Group 1 restoration with Ribbond Fiber placed at the cavity floor incorporated in Estelite Bulk-Fill Flow Universal composite (Tokuyama Dental Corporation Inc., Tokyo, Japan); Group 2 restoration with RF placed at 3 mm from the occlusal plane over a 2mm layer of Estelite Bulk-Fill Flow. The occlusal plane in both groups was restored with Ceram.x Spectra ST (Dentsply Sirona, Ballantyne Corporate Pl, Charlotte, NC, USA). The restored teeth were subjected to thermal cycling by immersing them for 30 seconds in hot water (55±2°C) followed by 30 seconds in cold water (5±2°C), for 2000 cycles.Their fracture strength was then evaluated using an Instron device. Data were analyzed with Two-sample T Test statistical test to compare fracture strength among groups. Finally, a descriptive analysis of the failure location was performed.</p><p><strong>Results: </strong>A statistically significant difference was found between groups 1 and 2 (<i>P</i><0.001) in terms of fracture strength. Group 2 exhibited a higher percentage of recoverable fractures compared to group 1. Group 1 had a mean fracture load of 833N and a SD of 248 while group 2 had a mean fracture load of 1286N and SD of 447.</p><p><strong>Conclusions: </strong>RF placed at 3 mm depth from the occlusal plane, on a 2 mm layer Estelite Bulk-Fill Flow Universal composite (Tokuyama Dental Corporation Inc., Tokyo, Japan) contributes to improve fracture resistance in vital teeth without interaxial dentin and reduces the risk of non-recoverable fractures compared to when it is placed at a 5 mm depth. <b>Key words:</b>Ribbond fiber, composite restoration, fracture resistance, Instron machine.</p>","PeriodicalId":15376,"journal":{"name":"Journal of Clinical and Experimental Dentistry","volume":"16 6","pages":"e707-e713"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310981/pdf/","citationCount":"0","resultStr":"{\"title\":\"Increasing the fracture strength of MOD restorations with Ribbond fibers.\",\"authors\":\"Francesca Zotti, Francesca Ferrari, Corrado Paganelli, Francesca Pilati, Giorgia Lanzaretti, Daniele Arlacchi, Nicoletta Zerman\",\"doi\":\"10.4317/jced.61608\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The aim of this study was to compare the fracture strength of two different Ribbond Fiber (Ribbond, Ribbond Inc., Seattle, WA, USA) restoration strategies in 5 mm deep standardized MOD cavities without interaxial dentin.</p><p><strong>Material and methods: </strong>34 extracted human molars were randomly divided into two groups and restored as follows: Group 1 restoration with Ribbond Fiber placed at the cavity floor incorporated in Estelite Bulk-Fill Flow Universal composite (Tokuyama Dental Corporation Inc., Tokyo, Japan); Group 2 restoration with RF placed at 3 mm from the occlusal plane over a 2mm layer of Estelite Bulk-Fill Flow. The occlusal plane in both groups was restored with Ceram.x Spectra ST (Dentsply Sirona, Ballantyne Corporate Pl, Charlotte, NC, USA). The restored teeth were subjected to thermal cycling by immersing them for 30 seconds in hot water (55±2°C) followed by 30 seconds in cold water (5±2°C), for 2000 cycles.Their fracture strength was then evaluated using an Instron device. Data were analyzed with Two-sample T Test statistical test to compare fracture strength among groups. Finally, a descriptive analysis of the failure location was performed.</p><p><strong>Results: </strong>A statistically significant difference was found between groups 1 and 2 (<i>P</i><0.001) in terms of fracture strength. Group 2 exhibited a higher percentage of recoverable fractures compared to group 1. Group 1 had a mean fracture load of 833N and a SD of 248 while group 2 had a mean fracture load of 1286N and SD of 447.</p><p><strong>Conclusions: </strong>RF placed at 3 mm depth from the occlusal plane, on a 2 mm layer Estelite Bulk-Fill Flow Universal composite (Tokuyama Dental Corporation Inc., Tokyo, Japan) contributes to improve fracture resistance in vital teeth without interaxial dentin and reduces the risk of non-recoverable fractures compared to when it is placed at a 5 mm depth. <b>Key words:</b>Ribbond fiber, composite restoration, fracture resistance, Instron machine.</p>\",\"PeriodicalId\":15376,\"journal\":{\"name\":\"Journal of Clinical and Experimental Dentistry\",\"volume\":\"16 6\",\"pages\":\"e707-e713\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310981/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical and Experimental Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4317/jced.61608\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical and Experimental Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4317/jced.61608","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
Increasing the fracture strength of MOD restorations with Ribbond fibers.
Background: The aim of this study was to compare the fracture strength of two different Ribbond Fiber (Ribbond, Ribbond Inc., Seattle, WA, USA) restoration strategies in 5 mm deep standardized MOD cavities without interaxial dentin.
Material and methods: 34 extracted human molars were randomly divided into two groups and restored as follows: Group 1 restoration with Ribbond Fiber placed at the cavity floor incorporated in Estelite Bulk-Fill Flow Universal composite (Tokuyama Dental Corporation Inc., Tokyo, Japan); Group 2 restoration with RF placed at 3 mm from the occlusal plane over a 2mm layer of Estelite Bulk-Fill Flow. The occlusal plane in both groups was restored with Ceram.x Spectra ST (Dentsply Sirona, Ballantyne Corporate Pl, Charlotte, NC, USA). The restored teeth were subjected to thermal cycling by immersing them for 30 seconds in hot water (55±2°C) followed by 30 seconds in cold water (5±2°C), for 2000 cycles.Their fracture strength was then evaluated using an Instron device. Data were analyzed with Two-sample T Test statistical test to compare fracture strength among groups. Finally, a descriptive analysis of the failure location was performed.
Results: A statistically significant difference was found between groups 1 and 2 (P<0.001) in terms of fracture strength. Group 2 exhibited a higher percentage of recoverable fractures compared to group 1. Group 1 had a mean fracture load of 833N and a SD of 248 while group 2 had a mean fracture load of 1286N and SD of 447.
Conclusions: RF placed at 3 mm depth from the occlusal plane, on a 2 mm layer Estelite Bulk-Fill Flow Universal composite (Tokuyama Dental Corporation Inc., Tokyo, Japan) contributes to improve fracture resistance in vital teeth without interaxial dentin and reduces the risk of non-recoverable fractures compared to when it is placed at a 5 mm depth. Key words:Ribbond fiber, composite restoration, fracture resistance, Instron machine.
期刊介绍:
Indexed in PUBMED, PubMed Central® (PMC) since 2012 and SCOPUSJournal of Clinical and Experimental Dentistry is an Open Access (free access on-line) - http://www.medicinaoral.com/odo/indice.htm. The aim of the Journal of Clinical and Experimental Dentistry is: - Periodontology - Community and Preventive Dentistry - Esthetic Dentistry - Biomaterials and Bioengineering in Dentistry - Operative Dentistry and Endodontics - Prosthetic Dentistry - Orthodontics - Oral Medicine and Pathology - Odontostomatology for the disabled or special patients - Oral Surgery