水温对后踝夹板挠曲强度的影响:实验研究

IF 0.6 Q4 ORTHOPEDICS Malaysian Orthopaedic Journal Pub Date : 2024-07-01 DOI:10.5704/MOJ.2407.011
C Pirot, N Sirimahatthanakul, A Naowanirut, T Sirithiantong
{"title":"水温对后踝夹板挠曲强度的影响:实验研究","authors":"C Pirot, N Sirimahatthanakul, A Naowanirut, T Sirithiantong","doi":"10.5704/MOJ.2407.011","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Plaster of Paris splints are commonly utilised for foot and ankle injuries. However, during follow-ups, some of these splints were found to be broken. Various methods, including splint form or augmentation changes, have been explored to enhance flexural strength. However, the impact of water temperature on the splint's flexural strength still needs to be studied. This research aimed to investigate the effect of water temperature on the flexural strength of the Plaster of Paris splint.</p><p><strong>Materials and methods: </strong>Three groups were set up based on different water temperatures: cold, hot, and room temperature. Posterior ankle splints were created and immersed in water at these varying temperatures, with five pieces tested per group. The splints were then allowed to harden fully over three days. Each splint underwent a tensile strength test using an axial pressure machine, which recorded their flexural strength data.</p><p><strong>Results: </strong>There were no statistically significant differences in the general characteristics of the splints. The flexural strengths of the three splint groups (pre-cooled, pre-heated, and room temperature) were 182.6N, 162.45N, and 228.91N, respectively. Statistical analysis revealed that room-temperature splints demonstrated a statistically significant increase in flexural strength compared to pre-heated splints (p<0.05). However, they did not differ significantly from pre-cooled splints.</p><p><strong>Conclusion: </strong>The highest flexural strength was observed in splints immersed in room-temperature water.</p>","PeriodicalId":45241,"journal":{"name":"Malaysian Orthopaedic Journal","volume":"18 2","pages":"77-82"},"PeriodicalIF":0.6000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11315946/pdf/","citationCount":"0","resultStr":"{\"title\":\"Water Temperature Effect on Flexural Strength of Posterior Ankle Splint: An Experimental Study.\",\"authors\":\"C Pirot, N Sirimahatthanakul, A Naowanirut, T Sirithiantong\",\"doi\":\"10.5704/MOJ.2407.011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Plaster of Paris splints are commonly utilised for foot and ankle injuries. However, during follow-ups, some of these splints were found to be broken. Various methods, including splint form or augmentation changes, have been explored to enhance flexural strength. However, the impact of water temperature on the splint's flexural strength still needs to be studied. This research aimed to investigate the effect of water temperature on the flexural strength of the Plaster of Paris splint.</p><p><strong>Materials and methods: </strong>Three groups were set up based on different water temperatures: cold, hot, and room temperature. Posterior ankle splints were created and immersed in water at these varying temperatures, with five pieces tested per group. The splints were then allowed to harden fully over three days. Each splint underwent a tensile strength test using an axial pressure machine, which recorded their flexural strength data.</p><p><strong>Results: </strong>There were no statistically significant differences in the general characteristics of the splints. The flexural strengths of the three splint groups (pre-cooled, pre-heated, and room temperature) were 182.6N, 162.45N, and 228.91N, respectively. Statistical analysis revealed that room-temperature splints demonstrated a statistically significant increase in flexural strength compared to pre-heated splints (p<0.05). However, they did not differ significantly from pre-cooled splints.</p><p><strong>Conclusion: </strong>The highest flexural strength was observed in splints immersed in room-temperature water.</p>\",\"PeriodicalId\":45241,\"journal\":{\"name\":\"Malaysian Orthopaedic Journal\",\"volume\":\"18 2\",\"pages\":\"77-82\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11315946/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Malaysian Orthopaedic Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5704/MOJ.2407.011\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Malaysian Orthopaedic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5704/MOJ.2407.011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

简介巴黎石膏夹板通常用于治疗足踝损伤。然而,在随访过程中发现,其中一些夹板已经破损。为了提高夹板的抗弯强度,人们探索了各种方法,包括改变夹板形状或增加夹板厚度。然而,水温对夹板抗弯强度的影响仍有待研究。本研究旨在探讨水温对巴黎石膏夹板抗弯强度的影响:根据不同的水温分为三组:冷水组、热水组和室温组。制作后踝夹板并将其浸入这些不同温度的水中,每组测试五块夹板。然后让夹板在三天内完全硬化。使用轴向压力机对每块夹板进行拉伸强度测试,并记录其抗弯强度数据:结果:三种夹板的总体特征在统计学上没有明显差异。三组夹板(预冷、预热和室温)的抗弯强度分别为 182.6N、162.45N 和 228.91N。统计分析表明,与预热夹板相比,室温夹板的抗弯强度在统计学上有显著提高(p 结论:浸泡在室温水中的夹板的抗弯强度最高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Water Temperature Effect on Flexural Strength of Posterior Ankle Splint: An Experimental Study.

Introduction: Plaster of Paris splints are commonly utilised for foot and ankle injuries. However, during follow-ups, some of these splints were found to be broken. Various methods, including splint form or augmentation changes, have been explored to enhance flexural strength. However, the impact of water temperature on the splint's flexural strength still needs to be studied. This research aimed to investigate the effect of water temperature on the flexural strength of the Plaster of Paris splint.

Materials and methods: Three groups were set up based on different water temperatures: cold, hot, and room temperature. Posterior ankle splints were created and immersed in water at these varying temperatures, with five pieces tested per group. The splints were then allowed to harden fully over three days. Each splint underwent a tensile strength test using an axial pressure machine, which recorded their flexural strength data.

Results: There were no statistically significant differences in the general characteristics of the splints. The flexural strengths of the three splint groups (pre-cooled, pre-heated, and room temperature) were 182.6N, 162.45N, and 228.91N, respectively. Statistical analysis revealed that room-temperature splints demonstrated a statistically significant increase in flexural strength compared to pre-heated splints (p<0.05). However, they did not differ significantly from pre-cooled splints.

Conclusion: The highest flexural strength was observed in splints immersed in room-temperature water.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
104
审稿时长
24 weeks
期刊介绍: The Malaysian Orthopaedic Journal is a peer-reviewed journal that publishes original papers and case reports three times a year in both printed and electronic version. The purpose of MOJ is to disseminate new knowledge and provide updates in Orthopaedics, trauma and musculoskeletal research. It is an Open Access journal that does not require processing fee or article processing charge from the authors. The Malaysian Orthopaedic Journal is the official journal of Malaysian Orthopaedic Association (MOA) and ASEAN Orthopaedic Association (AOA).
期刊最新文献
Dabigatran-induced Enterococcus Necrotizing Fasciitis in Medically Unfit Patient with Successful Conservative Treatment Outcome: A Case Report. Early Intervention in Post-operative Infectious Spondylodiscitis: Outcome of Aggressive Transforaminal Lumbar Interbody Fusion. Functional Bracing in a Femur Non-union Following Fracture Related Infection: A Case Report. Feasibility and Cost-Effectiveness of Daycare Anterior Cruciate Ligament Reconstruction - A Retrospective Case Series. Fibula Pro-tibia or Tibial Pro-fibula Dilemma: Order Defines Meaning.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1