在血液透析中使用分流侧 SpO2 监测仪测量连续心输出量估计值的可靠性和益处。

Koji Nakai, Yuichi Hirate, Takashi Nakajima, Atsushi Doi, Takeyuki Hiramatsu, Toshie Higaki, Aiko Nakai
{"title":"在血液透析中使用分流侧 SpO2 监测仪测量连续心输出量估计值的可靠性和益处。","authors":"Koji Nakai, Yuichi Hirate, Takashi Nakajima, Atsushi Doi, Takeyuki Hiramatsu, Toshie Higaki, Aiko Nakai","doi":"10.1111/1744-9987.14193","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Estimated continuous cardiac output (esCCO) is a novel technology that enables non-invasive and continuous monitoring of cardiac output. We compared the concordance in accuracies among esCCO measurements in the shunt limb and non-shunt limb.</p><p><strong>Methods: </strong>In this single-center prospective observational study, we include Japanese patients who underwent dialysis at our center between April 27, 2021, and February 28, 2023. Clinical accuracy of esCCO was evaluated in the shunted and non-shunted bilateral digits. Agreement between the measurements was analyzed using Lin's congruent correlation and Bland-Altman analysis.</p><p><strong>Results: </strong>For 43 individuals, Lin's concordance correlation coefficient was 0.9887 (95% confidence interval of 0.9886-0.9887) indicating good agreement. The values of esCCO measured in the shunt and non-shunt limbs were compatible. The percentage errors for the 43 patients with arterio-venous fistula (AVF) or arterio-venous graft (AVG), 32 with AVF, and 11 with AVG were 9.3%, 9.3%, and 8.9%, respectively.</p><p><strong>Conclusion: </strong>esCCO could be used in shunt as well as non-shunt limbs during dialysis, allowing continuous and non-invasive hemodynamic monitoring.</p>","PeriodicalId":94253,"journal":{"name":"Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy","volume":" ","pages":"61-69"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11695090/pdf/","citationCount":"0","resultStr":"{\"title\":\"Reliability and benefit of estimated continuous cardiac output measurement using shunt-side SpO<sub>2</sub> monitor in hemodialysis.\",\"authors\":\"Koji Nakai, Yuichi Hirate, Takashi Nakajima, Atsushi Doi, Takeyuki Hiramatsu, Toshie Higaki, Aiko Nakai\",\"doi\":\"10.1111/1744-9987.14193\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Estimated continuous cardiac output (esCCO) is a novel technology that enables non-invasive and continuous monitoring of cardiac output. We compared the concordance in accuracies among esCCO measurements in the shunt limb and non-shunt limb.</p><p><strong>Methods: </strong>In this single-center prospective observational study, we include Japanese patients who underwent dialysis at our center between April 27, 2021, and February 28, 2023. Clinical accuracy of esCCO was evaluated in the shunted and non-shunted bilateral digits. Agreement between the measurements was analyzed using Lin's congruent correlation and Bland-Altman analysis.</p><p><strong>Results: </strong>For 43 individuals, Lin's concordance correlation coefficient was 0.9887 (95% confidence interval of 0.9886-0.9887) indicating good agreement. The values of esCCO measured in the shunt and non-shunt limbs were compatible. The percentage errors for the 43 patients with arterio-venous fistula (AVF) or arterio-venous graft (AVG), 32 with AVF, and 11 with AVG were 9.3%, 9.3%, and 8.9%, respectively.</p><p><strong>Conclusion: </strong>esCCO could be used in shunt as well as non-shunt limbs during dialysis, allowing continuous and non-invasive hemodynamic monitoring.</p>\",\"PeriodicalId\":94253,\"journal\":{\"name\":\"Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy\",\"volume\":\" \",\"pages\":\"61-69\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11695090/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1111/1744-9987.14193\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/1744-9987.14193","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/11 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

简介估计连续心输出量(esCCO)是一种新型技术,可对心输出量进行无创和连续监测。我们比较了分流肢体和非分流肢体的 esCCO 测量精度的一致性:在这项单中心前瞻性观察研究中,我们纳入了 2021 年 4 月 27 日至 2023 年 2 月 28 日期间在本中心接受透析治疗的日本患者。对分流和非分流双侧肢体的 esCCO 临床准确性进行了评估。使用林氏同调相关性和布兰德-阿尔特曼分析法分析测量结果之间的一致性:43人的林氏一致性相关系数为0.9887(95%置信区间为0.9886-0.9887),表明测量结果具有良好的一致性。分流肢体和非分流肢体测得的 esCCO 值是一致的。43例动静脉瘘(AVF)或动静脉移植(AVG)患者、32例动静脉瘘患者和11例动静脉移植患者的误差百分比分别为9.3%、9.3%和8.9%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reliability and benefit of estimated continuous cardiac output measurement using shunt-side SpO2 monitor in hemodialysis.

Introduction: Estimated continuous cardiac output (esCCO) is a novel technology that enables non-invasive and continuous monitoring of cardiac output. We compared the concordance in accuracies among esCCO measurements in the shunt limb and non-shunt limb.

Methods: In this single-center prospective observational study, we include Japanese patients who underwent dialysis at our center between April 27, 2021, and February 28, 2023. Clinical accuracy of esCCO was evaluated in the shunted and non-shunted bilateral digits. Agreement between the measurements was analyzed using Lin's congruent correlation and Bland-Altman analysis.

Results: For 43 individuals, Lin's concordance correlation coefficient was 0.9887 (95% confidence interval of 0.9886-0.9887) indicating good agreement. The values of esCCO measured in the shunt and non-shunt limbs were compatible. The percentage errors for the 43 patients with arterio-venous fistula (AVF) or arterio-venous graft (AVG), 32 with AVF, and 11 with AVG were 9.3%, 9.3%, and 8.9%, respectively.

Conclusion: esCCO could be used in shunt as well as non-shunt limbs during dialysis, allowing continuous and non-invasive hemodynamic monitoring.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Frequent, perseverant therapy with plasma exchange in Japanese patients with rapidly progressive interstitial lung disease caused by anti-MDA5 antibody-positive dermatomyositis: A report of two cases. Lower time-averaged serum uric acid was associated with increased mortality in peritoneal dialysis patients. Clinical outcomes of endovascular treatment in hemodialysis patients with central venous stenosis: A retrospective analysis. Lower dry weight is associated with post-hemodialysis hypokalemia. Corporate Members.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1