领圈参数对弯道处圆形桥墩周围局部冲刷机制的影响

IF 5.7 3区 环境科学与生态学 Q1 WATER RESOURCES Applied Water Science Pub Date : 2024-08-12 DOI:10.1007/s13201-024-02257-5
Mohammad Moghanloo, Mohammad Vaghefi, Masoud Ghodsian, Ozgur Kisi
{"title":"领圈参数对弯道处圆形桥墩周围局部冲刷机制的影响","authors":"Mohammad Moghanloo,&nbsp;Mohammad Vaghefi,&nbsp;Masoud Ghodsian,&nbsp;Ozgur Kisi","doi":"10.1007/s13201-024-02257-5","DOIUrl":null,"url":null,"abstract":"<div><p>Analysis of bridge failures due to scouring has been extensively studied by different researchers in recent years and as a result various methods of controlling local scour cavity have been given. Since most of the research in this field has been done on straight paths and also the complexity of the flow pattern in bends, studying the scouring pattern around the bridge piers located in the bends has become a necessity. Therefore, one of the main objectives of this study is to investigate the scouring around the circular piers which are protected by collars at the river bends. The performance of the collar significantly depends on its level around the pier, which has been studied in this study. The results showed that the optimal performance of this structure, in positions 60°, 90° and 120° at the level of 0.2 pier width under the bed with 3 mm thickness (0.06 of pier width) by approximately 68, 63 and 70% of the maximum pier scour depth was reduced compared with collarless pier, respectively. By analyzing the results of this research, it was observed that the optimum level range of collar around the pier at various bend angles is the initial bed level up to 0.4 times the pier width at the bottom of the incipient level of the bed. Moreover, getting closer to the plate placement level toward the initial bed elevation enhances the collar’s function in decreasing scouring.</p></div>","PeriodicalId":8374,"journal":{"name":"Applied Water Science","volume":"14 9","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2024-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s13201-024-02257-5.pdf","citationCount":"0","resultStr":"{\"title\":\"The influence of collar parameters on local scour mechanism around the circular pier at the bend\",\"authors\":\"Mohammad Moghanloo,&nbsp;Mohammad Vaghefi,&nbsp;Masoud Ghodsian,&nbsp;Ozgur Kisi\",\"doi\":\"10.1007/s13201-024-02257-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Analysis of bridge failures due to scouring has been extensively studied by different researchers in recent years and as a result various methods of controlling local scour cavity have been given. Since most of the research in this field has been done on straight paths and also the complexity of the flow pattern in bends, studying the scouring pattern around the bridge piers located in the bends has become a necessity. Therefore, one of the main objectives of this study is to investigate the scouring around the circular piers which are protected by collars at the river bends. The performance of the collar significantly depends on its level around the pier, which has been studied in this study. The results showed that the optimal performance of this structure, in positions 60°, 90° and 120° at the level of 0.2 pier width under the bed with 3 mm thickness (0.06 of pier width) by approximately 68, 63 and 70% of the maximum pier scour depth was reduced compared with collarless pier, respectively. By analyzing the results of this research, it was observed that the optimum level range of collar around the pier at various bend angles is the initial bed level up to 0.4 times the pier width at the bottom of the incipient level of the bed. Moreover, getting closer to the plate placement level toward the initial bed elevation enhances the collar’s function in decreasing scouring.</p></div>\",\"PeriodicalId\":8374,\"journal\":{\"name\":\"Applied Water Science\",\"volume\":\"14 9\",\"pages\":\"\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s13201-024-02257-5.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Water Science\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s13201-024-02257-5\",\"RegionNum\":3,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"WATER RESOURCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Water Science","FirstCategoryId":"93","ListUrlMain":"https://link.springer.com/article/10.1007/s13201-024-02257-5","RegionNum":3,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"WATER RESOURCES","Score":null,"Total":0}
引用次数: 0

摘要

近年来,不同的研究人员对冲刷导致的桥梁垮塌进行了广泛研究,并提出了各种控制局部冲刷空洞的方法。由于该领域的大部分研究都是针对直线路径的,而弯道中的水流模式又十分复杂,因此对位于弯道中的桥墩周围的冲刷模式进行研究就变得十分必要。因此,本研究的主要目标之一就是调查河道弯道处受护圈保护的圆形桥墩周围的冲刷情况。护圈的性能在很大程度上取决于其在桥墩周围的水平度,本研究对此进行了研究。研究结果表明,在厚度为 3 毫米(占桥墩宽度的 0.06)的河床下 0.2 桥墩宽度的 60°、90° 和 120°位置,该结构的最佳性能分别比无护栅桥墩的最大冲刷深度减少了约 68%、63% 和 70%。通过对研究结果的分析,可以发现在不同弯曲角度下,墩台周围轴铤的最佳水平范围是基床初始水平面至基床初始水平面底部 0.4 倍墩台宽度。此外,将钢板放置水平面向初始基床标高靠拢,可增强钢领在减少冲刷方面的功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The influence of collar parameters on local scour mechanism around the circular pier at the bend

Analysis of bridge failures due to scouring has been extensively studied by different researchers in recent years and as a result various methods of controlling local scour cavity have been given. Since most of the research in this field has been done on straight paths and also the complexity of the flow pattern in bends, studying the scouring pattern around the bridge piers located in the bends has become a necessity. Therefore, one of the main objectives of this study is to investigate the scouring around the circular piers which are protected by collars at the river bends. The performance of the collar significantly depends on its level around the pier, which has been studied in this study. The results showed that the optimal performance of this structure, in positions 60°, 90° and 120° at the level of 0.2 pier width under the bed with 3 mm thickness (0.06 of pier width) by approximately 68, 63 and 70% of the maximum pier scour depth was reduced compared with collarless pier, respectively. By analyzing the results of this research, it was observed that the optimum level range of collar around the pier at various bend angles is the initial bed level up to 0.4 times the pier width at the bottom of the incipient level of the bed. Moreover, getting closer to the plate placement level toward the initial bed elevation enhances the collar’s function in decreasing scouring.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Water Science
Applied Water Science WATER RESOURCES-
CiteScore
9.90
自引率
3.60%
发文量
268
审稿时长
13 weeks
期刊介绍:
期刊最新文献
Adoption challenges of environmental monitoring practices: case study of temperature data loggers in selected Australian vegetable supply chains Analytical study on 2D groundwater flow in a sloping unconfined aquifer under spatiotemporal recharge Evaluation of ZnO/NiO/kaolin nanocomposite as a sorbent/photocatalyst in hybrid water remediation process Water desalination using atmospheric pressure plasma combined with thermal treatment Studying the kinetic energy budget and moisture transport during a severe case of cyclogenesis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1