钢-混凝土结构中螺栓和 SFCBs 加固 PBL 复合连接件的剪切行为

IF 3 3区 工程技术 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Structural Concrete Pub Date : 2024-08-05 DOI:10.1002/suco.202400267
Fangwen Wu, Bitong Zhao, Zhuo Liu, Zirun Li, Lanqing He, Zhou Fan
{"title":"钢-混凝土结构中螺栓和 SFCBs 加固 PBL 复合连接件的剪切行为","authors":"Fangwen Wu, Bitong Zhao, Zhuo Liu, Zirun Li, Lanqing He, Zhou Fan","doi":"10.1002/suco.202400267","DOIUrl":null,"url":null,"abstract":"In order to fully utilize the advantages of stud and perfobond leiste (PBL) connectors, a new composite shear connector was proposed in which the studs were welded to the H‐beam of the PBL shear connectors. In addition, to further improve the durability performance of the structure, steel‐fiber‐reinforced polymer composite bars (SFCBs) were used to replace steel rebars as penetrating rebars. In this study, the shear behaviors of SFCBs‐reinforced composite shear connectors were investigated by push‐out tests. The effects of the number of studs, the number of holes, and the type of penetrating rebars on the failure mode, load–slip curve, and shear behavior of the composite shear connectors were analyzed. The specimens' failure modes were mainly shearing the studs and crushing the concrete. Increasing the number of studs and holes has resulted in an increase of at least 7.47% in the shear resistance and 12.36% in the stiffness. SFCB had little effect on the shear resistance and reduced the stiffness but could improve ductility, with a maximum improvement of 11.49%. Additionally, a finite element model was established for parametric analysis. The results showed that the diameter of the SFCB and hole had a significant impact on the shear resistance. An equation for calculating the shear resistance based on the contributions of various components has been established that was applicable to composite shear connectors and has good accuracy and applicability.","PeriodicalId":21988,"journal":{"name":"Structural Concrete","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Shear behavior of stud and SFCBs‐reinforced PBL composite connectors in steel‐concrete structures\",\"authors\":\"Fangwen Wu, Bitong Zhao, Zhuo Liu, Zirun Li, Lanqing He, Zhou Fan\",\"doi\":\"10.1002/suco.202400267\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to fully utilize the advantages of stud and perfobond leiste (PBL) connectors, a new composite shear connector was proposed in which the studs were welded to the H‐beam of the PBL shear connectors. In addition, to further improve the durability performance of the structure, steel‐fiber‐reinforced polymer composite bars (SFCBs) were used to replace steel rebars as penetrating rebars. In this study, the shear behaviors of SFCBs‐reinforced composite shear connectors were investigated by push‐out tests. The effects of the number of studs, the number of holes, and the type of penetrating rebars on the failure mode, load–slip curve, and shear behavior of the composite shear connectors were analyzed. The specimens' failure modes were mainly shearing the studs and crushing the concrete. Increasing the number of studs and holes has resulted in an increase of at least 7.47% in the shear resistance and 12.36% in the stiffness. SFCB had little effect on the shear resistance and reduced the stiffness but could improve ductility, with a maximum improvement of 11.49%. Additionally, a finite element model was established for parametric analysis. The results showed that the diameter of the SFCB and hole had a significant impact on the shear resistance. An equation for calculating the shear resistance based on the contributions of various components has been established that was applicable to composite shear connectors and has good accuracy and applicability.\",\"PeriodicalId\":21988,\"journal\":{\"name\":\"Structural Concrete\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structural Concrete\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1002/suco.202400267\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Concrete","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/suco.202400267","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

为了充分利用螺柱和 PBL 连接器的优势,我们提出了一种新型复合剪力连接器,将螺柱焊接到 PBL 剪力连接器的 H 型钢上。此外,为了进一步提高结构的耐久性能,还使用了钢纤维增强聚合物复合杆(SFCB)来替代钢筋作为贯穿钢筋。本研究通过推出试验研究了 SFCBs 增强复合材料剪切连接件的剪切行为。分析了螺柱数量、孔数量和贯穿钢筋类型对复合剪力连接件失效模式、载荷-滑移曲线和剪力行为的影响。试样的破坏模式主要是剪切螺柱和压碎混凝土。增加螺柱和孔的数量可使抗剪性能提高至少 7.47%,刚度提高 12.36%。SFCB 对抗剪性能的影响很小,并降低了刚度,但可以改善延展性,最大改善幅度为 11.49%。此外,还建立了有限元模型进行参数分析。结果表明,SFCB 和孔的直径对抗剪性能有显著影响。根据各种成分的贡献建立了一个计算抗剪能力的方程,该方程适用于复合材料抗剪连接器,具有良好的准确性和适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Shear behavior of stud and SFCBs‐reinforced PBL composite connectors in steel‐concrete structures
In order to fully utilize the advantages of stud and perfobond leiste (PBL) connectors, a new composite shear connector was proposed in which the studs were welded to the H‐beam of the PBL shear connectors. In addition, to further improve the durability performance of the structure, steel‐fiber‐reinforced polymer composite bars (SFCBs) were used to replace steel rebars as penetrating rebars. In this study, the shear behaviors of SFCBs‐reinforced composite shear connectors were investigated by push‐out tests. The effects of the number of studs, the number of holes, and the type of penetrating rebars on the failure mode, load–slip curve, and shear behavior of the composite shear connectors were analyzed. The specimens' failure modes were mainly shearing the studs and crushing the concrete. Increasing the number of studs and holes has resulted in an increase of at least 7.47% in the shear resistance and 12.36% in the stiffness. SFCB had little effect on the shear resistance and reduced the stiffness but could improve ductility, with a maximum improvement of 11.49%. Additionally, a finite element model was established for parametric analysis. The results showed that the diameter of the SFCB and hole had a significant impact on the shear resistance. An equation for calculating the shear resistance based on the contributions of various components has been established that was applicable to composite shear connectors and has good accuracy and applicability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Structural Concrete
Structural Concrete CONSTRUCTION & BUILDING TECHNOLOGY-ENGINEERING, CIVIL
CiteScore
5.60
自引率
15.60%
发文量
284
审稿时长
3 months
期刊介绍: Structural Concrete, the official journal of the fib, provides conceptual and procedural guidance in the field of concrete construction, and features peer-reviewed papers, keynote research and industry news covering all aspects of the design, construction, performance in service and demolition of concrete structures. Main topics: design, construction, performance in service, conservation (assessment, maintenance, strengthening) and demolition of concrete structures research about the behaviour of concrete structures development of design methods fib Model Code sustainability of concrete structures.
期刊最新文献
Development of a new analytical model for circular concrete ring segments with dry joints under combined effects Fiber orientation and orientation factors in steel fiber‐reinforced concrete beams with hybrid fibers: A critical review Load‐path analysis of transverse tensile stresses in multiple‐pile caps Mechanical behavior of prestressed UHPC wind turbine tower columns under combined axial compression and bending Experimental investigation on mechanical property and hydration process of sintered sludge cement paste at different water‐binder ratios and curing ages
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1