{"title":"基于 X 射线荧光的在线监测仪性能评估,用于检测环境颗粒物中的元素浓度","authors":"Ivonne Trebs, Céline Lett, Andreas Krein, Erika Matsumoto Kawaguchi, Jürgen Junk","doi":"10.5194/amt-2024-134","DOIUrl":null,"url":null,"abstract":"<strong>Abstract.</strong> Knowledge of the chemical composition of particulate matter (PM) is essential for understanding its source distribution, identifying potential health impacts of toxic elements and to develop efficient air pollution abatement strategies. Traditional methods for analysing PM composition, such as collection on filter substrates and subsequent offline analysis with e.g., inductively coupled plasma mass spectrometry (ICP-MS), are time-consuming and prone to measurement errors due to multiple preparation steps. Emerging near-real time techniques based on non-destructive Energy Dispersive X-ray Fluorescence (EDXRF) offer advantages for continuous monitoring and source apportionment. This study characterises the Horiba PX-375 EDXRF monitor by applying a straightforward performance evaluation including (a) limit of detection (LoD), (b) identification and quantification of uncertainty sources, and (c) investigating and comparing measurement results from three contrasting sites in Luxembourg (urban, semi-urban, rural). We used multi-element reference materials (ME-RMs) from UC Davis for calibration and performed measurements during spring and summer 2023. The LoDs for toxic elements like Ni, Cu, Zn, and Pb were below 3 ng m<sup>-3</sup> at one-hour time resolution. Higher LoDs were observed for lighter elements (e.g., Al, Si, S, K, Ca). Expanded uncertainties ranged between 5 and 25 % for elemental concentrations above 20 ng m<sup>-3</sup> and were maximal for concentrations below 10 ng m<sup>-3</sup>, reaching 60–85 %. Elemental analysis revealed S and mineral elements (Fe, Si, Ca, Al) as dominant contributors to PM10. Toxic elements (As, Ni, Pb) were often below the LoD, suggesting minimal exposure risk in the sampled areas. Our results explained on average 51–74 % of the gravimetric PM10 mass at the three sites. The study highlights the suitability and importance of the continuous PX-375 particle monitor for future air quality monitoring and source apportionment studies, particularly under changing emission scenarios and air pollution abatement strategies.","PeriodicalId":8619,"journal":{"name":"Atmospheric Measurement Techniques","volume":"19 1","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance evaluation of an online monitor based on X-ray fluorescence for detecting elemental concentrations in ambient particulate matter\",\"authors\":\"Ivonne Trebs, Céline Lett, Andreas Krein, Erika Matsumoto Kawaguchi, Jürgen Junk\",\"doi\":\"10.5194/amt-2024-134\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<strong>Abstract.</strong> Knowledge of the chemical composition of particulate matter (PM) is essential for understanding its source distribution, identifying potential health impacts of toxic elements and to develop efficient air pollution abatement strategies. Traditional methods for analysing PM composition, such as collection on filter substrates and subsequent offline analysis with e.g., inductively coupled plasma mass spectrometry (ICP-MS), are time-consuming and prone to measurement errors due to multiple preparation steps. Emerging near-real time techniques based on non-destructive Energy Dispersive X-ray Fluorescence (EDXRF) offer advantages for continuous monitoring and source apportionment. This study characterises the Horiba PX-375 EDXRF monitor by applying a straightforward performance evaluation including (a) limit of detection (LoD), (b) identification and quantification of uncertainty sources, and (c) investigating and comparing measurement results from three contrasting sites in Luxembourg (urban, semi-urban, rural). We used multi-element reference materials (ME-RMs) from UC Davis for calibration and performed measurements during spring and summer 2023. The LoDs for toxic elements like Ni, Cu, Zn, and Pb were below 3 ng m<sup>-3</sup> at one-hour time resolution. Higher LoDs were observed for lighter elements (e.g., Al, Si, S, K, Ca). Expanded uncertainties ranged between 5 and 25 % for elemental concentrations above 20 ng m<sup>-3</sup> and were maximal for concentrations below 10 ng m<sup>-3</sup>, reaching 60–85 %. Elemental analysis revealed S and mineral elements (Fe, Si, Ca, Al) as dominant contributors to PM10. Toxic elements (As, Ni, Pb) were often below the LoD, suggesting minimal exposure risk in the sampled areas. Our results explained on average 51–74 % of the gravimetric PM10 mass at the three sites. The study highlights the suitability and importance of the continuous PX-375 particle monitor for future air quality monitoring and source apportionment studies, particularly under changing emission scenarios and air pollution abatement strategies.\",\"PeriodicalId\":8619,\"journal\":{\"name\":\"Atmospheric Measurement Techniques\",\"volume\":\"19 1\",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-08-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Atmospheric Measurement Techniques\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.5194/amt-2024-134\",\"RegionNum\":3,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"METEOROLOGY & ATMOSPHERIC SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atmospheric Measurement Techniques","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.5194/amt-2024-134","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"METEOROLOGY & ATMOSPHERIC SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

摘要了解颗粒物(PM)的化学成分对于了解其来源分布、确定有毒元素对健康的潜在影响以及制定有效的空气污染减排策略至关重要。传统的可吸入颗粒物成分分析方法,如在过滤基质上收集颗粒物,然后用电感耦合等离子体质谱法(ICP-MS)等进行离线分析,既耗时又容易因多个制备步骤而产生测量误差。基于非破坏性能量色散 X 射线荧光(EDXRF)的新兴近实时技术为连续监测和来源分配提供了优势。本研究对 Horiba PX-375 EDXRF 监测器进行了直接的性能评估,包括:(a) 检测极限 (LoD);(b) 不确定性源的识别和量化;(c) 调查和比较卢森堡三个不同地点(城市、半城市和农村)的测量结果。我们使用加州大学戴维斯分校的多元素参考材料 (ME-RM) 进行校准,并在 2023 年春季和夏季进行了测量。在一小时的时间分辨率下,镍、铜、锌和铅等有毒元素的 LoD 值低于 3 毫微克/立方米。轻元素(如 Al、Si、S、K、Ca)的 LoD 值较高。元素浓度超过 20 毫微克/立方米时,扩展不确定性在 5%到 25%之间,浓度低于 10 毫微克/立方米时,扩展不确定性最大,达到 60-85%。元素分析表明,S 和矿物元素(铁、硅、钙、铝)是 PM10 的主要成分。有毒元素(As、Ni、Pb)通常低于负荷极限(LoD),这表明采样区域的暴露风险极低。我们的研究结果平均解释了三个地点 PM10 重量的 51-74 %。这项研究强调了 PX-375 颗粒物连续监测仪在未来空气质量监测和污染源分配研究中的适用性和重要性,尤其是在不断变化的排放情景和空气污染减排策略下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance evaluation of an online monitor based on X-ray fluorescence for detecting elemental concentrations in ambient particulate matter
Abstract. Knowledge of the chemical composition of particulate matter (PM) is essential for understanding its source distribution, identifying potential health impacts of toxic elements and to develop efficient air pollution abatement strategies. Traditional methods for analysing PM composition, such as collection on filter substrates and subsequent offline analysis with e.g., inductively coupled plasma mass spectrometry (ICP-MS), are time-consuming and prone to measurement errors due to multiple preparation steps. Emerging near-real time techniques based on non-destructive Energy Dispersive X-ray Fluorescence (EDXRF) offer advantages for continuous monitoring and source apportionment. This study characterises the Horiba PX-375 EDXRF monitor by applying a straightforward performance evaluation including (a) limit of detection (LoD), (b) identification and quantification of uncertainty sources, and (c) investigating and comparing measurement results from three contrasting sites in Luxembourg (urban, semi-urban, rural). We used multi-element reference materials (ME-RMs) from UC Davis for calibration and performed measurements during spring and summer 2023. The LoDs for toxic elements like Ni, Cu, Zn, and Pb were below 3 ng m-3 at one-hour time resolution. Higher LoDs were observed for lighter elements (e.g., Al, Si, S, K, Ca). Expanded uncertainties ranged between 5 and 25 % for elemental concentrations above 20 ng m-3 and were maximal for concentrations below 10 ng m-3, reaching 60–85 %. Elemental analysis revealed S and mineral elements (Fe, Si, Ca, Al) as dominant contributors to PM10. Toxic elements (As, Ni, Pb) were often below the LoD, suggesting minimal exposure risk in the sampled areas. Our results explained on average 51–74 % of the gravimetric PM10 mass at the three sites. The study highlights the suitability and importance of the continuous PX-375 particle monitor for future air quality monitoring and source apportionment studies, particularly under changing emission scenarios and air pollution abatement strategies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Atmospheric Measurement Techniques
Atmospheric Measurement Techniques METEOROLOGY & ATMOSPHERIC SCIENCES-
CiteScore
7.10
自引率
18.40%
发文量
331
审稿时长
3 months
期刊介绍: Atmospheric Measurement Techniques (AMT) is an international scientific journal dedicated to the publication and discussion of advances in remote sensing, in-situ and laboratory measurement techniques for the constituents and properties of the Earth’s atmosphere. The main subject areas comprise the development, intercomparison and validation of measurement instruments and techniques of data processing and information retrieval for gases, aerosols, and clouds. The manuscript types considered for peer-reviewed publication are research articles, review articles, and commentaries.
期刊最新文献
Analyzing the chemical composition, morphology and size of ice-nucleating particles by coupling a scanning electron microscope to an offline diffusion chamber Wet-Radome Attenuation in ARM Cloud Radars and Its Utilization in Radar Calibration Using Disdrometer Measurements Chilean Observation Network De MeteOr Radars (CONDOR): Multi-Static System Configuration & Wind Comparison with Co-located Lidar Benchmarking KDP in Rainfall: A Quantitative Assessment of Estimation Algorithms Using C-Band Weather Radar Observations Advances in OH reactivity instruments for airborne field measurements
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1