提高超低剂量胸部 CT 的扫描速度和间距:对结节体积测量和图像质量的影响

Q4 Medicine Medicina Pub Date : 2024-08-12 DOI:10.3390/medicina60081301
Heejoo Bae, Ji Won Lee, Yeon Joo Jeong, Min-Hee Hwang, Geewon Lee
{"title":"提高超低剂量胸部 CT 的扫描速度和间距:对结节体积测量和图像质量的影响","authors":"Heejoo Bae, Ji Won Lee, Yeon Joo Jeong, Min-Hee Hwang, Geewon Lee","doi":"10.3390/medicina60081301","DOIUrl":null,"url":null,"abstract":"Background and Objectives: This study’s objective was to investigate the influence of increased scan speed and pitch on image quality and nodule volumetry in patients who underwent ultra-low-dose chest computed tomography (CT). Material and Methods: One hundred and two patients who had lung nodules were included in this study. Standard-speed, standard-pitch (SSSP) ultra-low-dose CT and high-speed, high-pitch (HSHP) ultra-low-dose CT were obtained for all patients. Image noise was measured as the standard deviation of attenuation. One hundred and sixty-three nodules were identified and classified according to location, volume, and nodule type. Volume measurement of detected pulmonary nodules was compared according to nodule location, volume, and nodule type. Motion artifacts at the right middle lobe, the lingular segment, and both lower lobes near the lung bases were evaluated. Subjective image quality analysis was also performed. Results: The HSHP CT scan demonstrated decreased motion artifacts at the left upper lobe lingular segment and left lower lobe compared to the SSSP CT scan (p < 0.001). The image noise was higher and the radiation dose was lower in the HSHP scan (p < 0.001). According to the nodule type, the absolute relative volume difference was significantly higher in ground glass opacity nodules compared with those of part-solid and solid nodules (p < 0.001). Conclusion: Our study results suggest that HSHP ultra-low-dose chest CT scans provide decreased motion artifacts and lower radiation doses compared to SSSP ultra-low-dose chest CT. However, lung nodule volumetry should be performed with caution for ground glass opacity nodules.","PeriodicalId":18512,"journal":{"name":"Medicina","volume":"199 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Increased Scan Speed and Pitch on Ultra-Low-Dose Chest CT: Effect on Nodule Volumetry and Image Quality\",\"authors\":\"Heejoo Bae, Ji Won Lee, Yeon Joo Jeong, Min-Hee Hwang, Geewon Lee\",\"doi\":\"10.3390/medicina60081301\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background and Objectives: This study’s objective was to investigate the influence of increased scan speed and pitch on image quality and nodule volumetry in patients who underwent ultra-low-dose chest computed tomography (CT). Material and Methods: One hundred and two patients who had lung nodules were included in this study. Standard-speed, standard-pitch (SSSP) ultra-low-dose CT and high-speed, high-pitch (HSHP) ultra-low-dose CT were obtained for all patients. Image noise was measured as the standard deviation of attenuation. One hundred and sixty-three nodules were identified and classified according to location, volume, and nodule type. Volume measurement of detected pulmonary nodules was compared according to nodule location, volume, and nodule type. Motion artifacts at the right middle lobe, the lingular segment, and both lower lobes near the lung bases were evaluated. Subjective image quality analysis was also performed. Results: The HSHP CT scan demonstrated decreased motion artifacts at the left upper lobe lingular segment and left lower lobe compared to the SSSP CT scan (p < 0.001). The image noise was higher and the radiation dose was lower in the HSHP scan (p < 0.001). According to the nodule type, the absolute relative volume difference was significantly higher in ground glass opacity nodules compared with those of part-solid and solid nodules (p < 0.001). Conclusion: Our study results suggest that HSHP ultra-low-dose chest CT scans provide decreased motion artifacts and lower radiation doses compared to SSSP ultra-low-dose chest CT. However, lung nodule volumetry should be performed with caution for ground glass opacity nodules.\",\"PeriodicalId\":18512,\"journal\":{\"name\":\"Medicina\",\"volume\":\"199 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medicina\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/medicina60081301\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicina","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/medicina60081301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:本研究旨在探讨提高扫描速度和螺距对超低剂量胸部计算机断层扫描(CT)患者的图像质量和结节体积的影响。材料和方法:本研究共纳入 112 名肺部结节患者。所有患者均接受了标准速度、标准间距(SSSP)超低剂量 CT 和高速、高间距(HSHP)超低剂量 CT 检查。图像噪声以衰减的标准偏差来衡量。确定了 163 个结节,并根据位置、体积和结节类型进行了分类。根据结节位置、体积和结节类型对检测到的肺结节的体积测量进行了比较。评估了右中叶、舌段和两个下叶靠近肺底的运动伪影。还进行了主观图像质量分析。结果与 SSSP CT 扫描相比,HSHP CT 扫描显示左肺上叶舌状段和左肺下叶的运动伪影减少(P < 0.001)。HSHP 扫描的图像噪声更高,辐射剂量更低(P < 0.001)。根据结节类型,磨玻璃不透明结节的绝对相对体积差异明显高于部分实性和实性结节(P < 0.001)。结论我们的研究结果表明,与 SSSP 超低剂量胸部 CT 相比,HSHP 超低剂量胸部 CT 扫描可减少运动伪影,降低辐射剂量。但是,在进行肺结节容积测量时,应谨慎对待磨玻璃不透明结节。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Increased Scan Speed and Pitch on Ultra-Low-Dose Chest CT: Effect on Nodule Volumetry and Image Quality
Background and Objectives: This study’s objective was to investigate the influence of increased scan speed and pitch on image quality and nodule volumetry in patients who underwent ultra-low-dose chest computed tomography (CT). Material and Methods: One hundred and two patients who had lung nodules were included in this study. Standard-speed, standard-pitch (SSSP) ultra-low-dose CT and high-speed, high-pitch (HSHP) ultra-low-dose CT were obtained for all patients. Image noise was measured as the standard deviation of attenuation. One hundred and sixty-three nodules were identified and classified according to location, volume, and nodule type. Volume measurement of detected pulmonary nodules was compared according to nodule location, volume, and nodule type. Motion artifacts at the right middle lobe, the lingular segment, and both lower lobes near the lung bases were evaluated. Subjective image quality analysis was also performed. Results: The HSHP CT scan demonstrated decreased motion artifacts at the left upper lobe lingular segment and left lower lobe compared to the SSSP CT scan (p < 0.001). The image noise was higher and the radiation dose was lower in the HSHP scan (p < 0.001). According to the nodule type, the absolute relative volume difference was significantly higher in ground glass opacity nodules compared with those of part-solid and solid nodules (p < 0.001). Conclusion: Our study results suggest that HSHP ultra-low-dose chest CT scans provide decreased motion artifacts and lower radiation doses compared to SSSP ultra-low-dose chest CT. However, lung nodule volumetry should be performed with caution for ground glass opacity nodules.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medicina
Medicina Medicine-Medicine (all)
CiteScore
0.10
自引率
0.00%
发文量
66
审稿时长
24 weeks
期刊介绍: Publicada con el apoyo del Ministerio de Ciencia, Tecnología e Innovación Productiva. Medicina no tiene propósitos comerciales. El objeto de su creación ha sido propender al adelanto de la medicina argentina. Los beneficios que pudieran obtenerse serán aplicados exclusivamente a ese fin.
期刊最新文献
Insights into the Two Most Common Cancers of Primitive Gut-Derived Structures and Their Microbial Connections Intravital Position Study of the Clinical Anatomy of the Middle Lobe and Superior Poles of the Thyroid Gland An Analysis of Emergency Surgical Outcomes for Pediatric Traumatic Brain Injury: A Ten-Year Single-Institute Retrospective Study in Taiwan Evaluation of Left Atrial Electromechanical Delay and Left Atrial Phasic Functions in Patients Undergoing Treatment with Cardiotoxic Chemotherapeutic Agents Self-Reported Gastrointestinal Symptoms Associated with NSAIDs and Caffeine Consumption in a Jordanian Subpopulation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1