Osuani Fyneface Idema, Malik Abdulwahab, Innocent Okechi Arukalam, Ifeyinwa Ekeke, Chigoziri N. Njoku, Chioma Anyiam, Benedict Onyeachu, Emeka Emmanuel Oguzie
{"title":"与苯并三唑相比,一种新型的腐蚀性离子封存技术:综述","authors":"Osuani Fyneface Idema, Malik Abdulwahab, Innocent Okechi Arukalam, Ifeyinwa Ekeke, Chigoziri N. Njoku, Chioma Anyiam, Benedict Onyeachu, Emeka Emmanuel Oguzie","doi":"10.1108/acmm-04-2024-3009","DOIUrl":null,"url":null,"abstract":"<h3>Purpose</h3>\n<p>Hexavalent chromium has been a benchmark corrosion inhibitor before it was phased out because of its carcinogenic properties. However, because it was phased out, many alternative corrosion inhibitors have been introduced but failed to meet the performance of this benchmark inhibitor. Consequently, benzotriazole (BTA) was reported to exhibit chromate-like inhibition performance. Subsequently, Intelli-ion was reported by researchers to exhibit chromate-like performance also with claims of being a unique alternative. This paper aims to review the inhibition performance of these two alternatives. Above all, promotes the unique inhibition performance of Intelli-ion that makes it suitable for application in many sectors.</p><!--/ Abstract__block -->\n<h3>Design/methodology/approach</h3>\n<p>In this paper, the corrosion inhibition performances of BTA and Intelli-ion were compared systematically by reviewing some related literatures based on the opinion of the authors.</p><!--/ Abstract__block -->\n<h3>Findings</h3>\n<p>Different methodologies for measuring the inhibition performance of BTA showed that it’s an inhibitor of choice. However, the cut edge corrosion performance of Intelli-ion and BTA corrosion inhibitors on galvanized steel of 55% Wt.% Al, 44% Wt.% Zn and 1% Wt.% Si in 5 Wt.% NaCl solution was compared when subjected to scanning vibrating electrode technique (SVET) for 24 h. The results showed faint blue-colored region depicting negative cathodic current density for the Intelli-ion while there was a high-intensity of red-colored region depicting a positive anodic current density for BTA. In other words, the Intelli-ion inhibitor had a better overall cut-edge corrosion inhibition performance than the BTA inhibitor.</p><!--/ Abstract__block -->\n<h3>Originality/value</h3>\n<p>This paper compares and further, summarizes the corrosion inhibition performance of Intelli-ion and BTA by evaluating SVET results from the literature. In addition, it serves as an overview and reference for the unique inhibition performance of Intelli-ion when applied in field applications.</p><!--/ Abstract__block -->","PeriodicalId":8217,"journal":{"name":"Anti-corrosion Methods and Materials","volume":"27 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel technology for sequestration of corrosive ions in comparison with benzotriazole: a review\",\"authors\":\"Osuani Fyneface Idema, Malik Abdulwahab, Innocent Okechi Arukalam, Ifeyinwa Ekeke, Chigoziri N. Njoku, Chioma Anyiam, Benedict Onyeachu, Emeka Emmanuel Oguzie\",\"doi\":\"10.1108/acmm-04-2024-3009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3>Purpose</h3>\\n<p>Hexavalent chromium has been a benchmark corrosion inhibitor before it was phased out because of its carcinogenic properties. However, because it was phased out, many alternative corrosion inhibitors have been introduced but failed to meet the performance of this benchmark inhibitor. Consequently, benzotriazole (BTA) was reported to exhibit chromate-like inhibition performance. Subsequently, Intelli-ion was reported by researchers to exhibit chromate-like performance also with claims of being a unique alternative. This paper aims to review the inhibition performance of these two alternatives. Above all, promotes the unique inhibition performance of Intelli-ion that makes it suitable for application in many sectors.</p><!--/ Abstract__block -->\\n<h3>Design/methodology/approach</h3>\\n<p>In this paper, the corrosion inhibition performances of BTA and Intelli-ion were compared systematically by reviewing some related literatures based on the opinion of the authors.</p><!--/ Abstract__block -->\\n<h3>Findings</h3>\\n<p>Different methodologies for measuring the inhibition performance of BTA showed that it’s an inhibitor of choice. However, the cut edge corrosion performance of Intelli-ion and BTA corrosion inhibitors on galvanized steel of 55% Wt.% Al, 44% Wt.% Zn and 1% Wt.% Si in 5 Wt.% NaCl solution was compared when subjected to scanning vibrating electrode technique (SVET) for 24 h. The results showed faint blue-colored region depicting negative cathodic current density for the Intelli-ion while there was a high-intensity of red-colored region depicting a positive anodic current density for BTA. In other words, the Intelli-ion inhibitor had a better overall cut-edge corrosion inhibition performance than the BTA inhibitor.</p><!--/ Abstract__block -->\\n<h3>Originality/value</h3>\\n<p>This paper compares and further, summarizes the corrosion inhibition performance of Intelli-ion and BTA by evaluating SVET results from the literature. In addition, it serves as an overview and reference for the unique inhibition performance of Intelli-ion when applied in field applications.</p><!--/ Abstract__block -->\",\"PeriodicalId\":8217,\"journal\":{\"name\":\"Anti-corrosion Methods and Materials\",\"volume\":\"27 1\",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anti-corrosion Methods and Materials\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1108/acmm-04-2024-3009\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"METALLURGY & METALLURGICAL ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anti-corrosion Methods and Materials","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1108/acmm-04-2024-3009","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"METALLURGY & METALLURGICAL ENGINEERING","Score":null,"Total":0}
A novel technology for sequestration of corrosive ions in comparison with benzotriazole: a review
Purpose
Hexavalent chromium has been a benchmark corrosion inhibitor before it was phased out because of its carcinogenic properties. However, because it was phased out, many alternative corrosion inhibitors have been introduced but failed to meet the performance of this benchmark inhibitor. Consequently, benzotriazole (BTA) was reported to exhibit chromate-like inhibition performance. Subsequently, Intelli-ion was reported by researchers to exhibit chromate-like performance also with claims of being a unique alternative. This paper aims to review the inhibition performance of these two alternatives. Above all, promotes the unique inhibition performance of Intelli-ion that makes it suitable for application in many sectors.
Design/methodology/approach
In this paper, the corrosion inhibition performances of BTA and Intelli-ion were compared systematically by reviewing some related literatures based on the opinion of the authors.
Findings
Different methodologies for measuring the inhibition performance of BTA showed that it’s an inhibitor of choice. However, the cut edge corrosion performance of Intelli-ion and BTA corrosion inhibitors on galvanized steel of 55% Wt.% Al, 44% Wt.% Zn and 1% Wt.% Si in 5 Wt.% NaCl solution was compared when subjected to scanning vibrating electrode technique (SVET) for 24 h. The results showed faint blue-colored region depicting negative cathodic current density for the Intelli-ion while there was a high-intensity of red-colored region depicting a positive anodic current density for BTA. In other words, the Intelli-ion inhibitor had a better overall cut-edge corrosion inhibition performance than the BTA inhibitor.
Originality/value
This paper compares and further, summarizes the corrosion inhibition performance of Intelli-ion and BTA by evaluating SVET results from the literature. In addition, it serves as an overview and reference for the unique inhibition performance of Intelli-ion when applied in field applications.
期刊介绍:
Anti-Corrosion Methods and Materials publishes a broad coverage of the materials and techniques employed in corrosion prevention. Coverage is essentially of a practical nature and designed to be of material benefit to those working in the field. Proven applications are covered together with company news and new product information. Anti-Corrosion Methods and Materials now also includes research articles that reflect the most interesting and strategically important research and development activities from around the world.
Every year, industry pays a massive and rising cost for its corrosion problems. Research and development into new materials, processes and initiatives to combat this loss is increasing, and new findings are constantly coming to light which can help to beat corrosion problems throughout industry. This journal uniquely focuses on these exciting developments to make essential reading for anyone aiming to regain profits lost through corrosion difficulties.
• New methods, materials and software
• New developments in research and industry
• Stainless steels
• Protection of structural steelwork
• Industry update, conference news, dates and events
• Environmental issues
• Health & safety, including EC regulations
• Corrosion monitoring and plant health assessment
• The latest equipment and processes
• Corrosion cost and corrosion risk management.