Adam Cewers , Torgny Sunnerhagen , Patrik Gilje , Fredrik Wannheden , Jonas Bläckberg , Per Wierup , Mårten Larsson , Magnus Rasmussen
{"title":"即使是单一的血液培养阳性也可能有影响--一例由克罗彭氏棒状杆菌引起的人工瓣膜感染性心内膜炎病例","authors":"Adam Cewers , Torgny Sunnerhagen , Patrik Gilje , Fredrik Wannheden , Jonas Bläckberg , Per Wierup , Mårten Larsson , Magnus Rasmussen","doi":"10.1016/j.idcr.2024.e02049","DOIUrl":null,"url":null,"abstract":"<div><p><em>Corynebacterium</em> is a skin commensal bacterium that can contaminate blood cultures. It is however also a rare cause of infective endocarditis (IE). Here we report a case of <em>Corynebacterium kroppenstedtii</em> aortic prosthesis IE in a 76-year-old man where only a single blood culture bottle was positive initially. <em>C. kroppenstedtii</em> is a very rare cause of IE, only reported two times previously. The diagnosis in our case was confirmed by repeated blood culture positivity and eventually by detection of DNA from <em>C. kroppenstedtii</em> on heart valves after valve exchange surgery. At surgery an aortic root abscess was detected and the valve was replaced by a homograft. Recovery was complicated by antibiotic-induced nephrotoxicity and treatment was concluded with moxifloxacin in combination with rifampicin. Recovery was uneventful. This case demonstrates that growth in even a single blood culture bottle may be important in patients with prosthetic heart valves.</p></div>","PeriodicalId":47045,"journal":{"name":"IDCases","volume":"37 ","pages":"Article e02049"},"PeriodicalIF":1.1000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2214250924001252/pdfft?md5=a4b5a56a62d82aa038dbdb247a4c5abc&pid=1-s2.0-S2214250924001252-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Even a single positive blood culture may matter – A case of prosthetic valve infective endocarditis caused by Corynebacterium kroppenstedtii\",\"authors\":\"Adam Cewers , Torgny Sunnerhagen , Patrik Gilje , Fredrik Wannheden , Jonas Bläckberg , Per Wierup , Mårten Larsson , Magnus Rasmussen\",\"doi\":\"10.1016/j.idcr.2024.e02049\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p><em>Corynebacterium</em> is a skin commensal bacterium that can contaminate blood cultures. It is however also a rare cause of infective endocarditis (IE). Here we report a case of <em>Corynebacterium kroppenstedtii</em> aortic prosthesis IE in a 76-year-old man where only a single blood culture bottle was positive initially. <em>C. kroppenstedtii</em> is a very rare cause of IE, only reported two times previously. The diagnosis in our case was confirmed by repeated blood culture positivity and eventually by detection of DNA from <em>C. kroppenstedtii</em> on heart valves after valve exchange surgery. At surgery an aortic root abscess was detected and the valve was replaced by a homograft. Recovery was complicated by antibiotic-induced nephrotoxicity and treatment was concluded with moxifloxacin in combination with rifampicin. Recovery was uneventful. This case demonstrates that growth in even a single blood culture bottle may be important in patients with prosthetic heart valves.</p></div>\",\"PeriodicalId\":47045,\"journal\":{\"name\":\"IDCases\",\"volume\":\"37 \",\"pages\":\"Article e02049\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2214250924001252/pdfft?md5=a4b5a56a62d82aa038dbdb247a4c5abc&pid=1-s2.0-S2214250924001252-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IDCases\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2214250924001252\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INFECTIOUS DISEASES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IDCases","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214250924001252","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
Even a single positive blood culture may matter – A case of prosthetic valve infective endocarditis caused by Corynebacterium kroppenstedtii
Corynebacterium is a skin commensal bacterium that can contaminate blood cultures. It is however also a rare cause of infective endocarditis (IE). Here we report a case of Corynebacterium kroppenstedtii aortic prosthesis IE in a 76-year-old man where only a single blood culture bottle was positive initially. C. kroppenstedtii is a very rare cause of IE, only reported two times previously. The diagnosis in our case was confirmed by repeated blood culture positivity and eventually by detection of DNA from C. kroppenstedtii on heart valves after valve exchange surgery. At surgery an aortic root abscess was detected and the valve was replaced by a homograft. Recovery was complicated by antibiotic-induced nephrotoxicity and treatment was concluded with moxifloxacin in combination with rifampicin. Recovery was uneventful. This case demonstrates that growth in even a single blood culture bottle may be important in patients with prosthetic heart valves.