Sabah Daniar, Mojtaba Shiroei, Amirhossein Khosravi Sarvenoee
{"title":"通过创新保护算法提高第二区域内部故障的距离保护速度","authors":"Sabah Daniar, Mojtaba Shiroei, Amirhossein Khosravi Sarvenoee","doi":"10.1155/2024/9100505","DOIUrl":null,"url":null,"abstract":"<div>\n <p>Electric power systems constantly encounter disturbances and faults, necessitating fast and precise identification and rectification of these issues. This is crucial for ensuring the stability and reliability of the system. This paper introduces a protection scheme for accelerating the second zone operation of the distance relay during internal faults. The proposed scheme exploits the locus of power with positive power characteristics to effectively distinguish between internal and external faults. This is achieved by detecting the remote circuit breaker operation (RCBO). The locus of power remains predominantly within regions 1 or 2, with occasional transfers between these regions due to internal faults prior to and following the RCBO. Conversely, in the case of external faults, regions 3 or 4 are implicated. This distinct variation in the locus of power is applied to derive the protection algorithm. This is affirmed through sequence network analysis of various faults in the transmission line. The cumulative rate of change in relative reactive power has been employed for single-phase RCBO detection. The proposed protection logic employs supplementary undervoltage logic to avoid single-phase operation during two-phase and three-phase faults. The simulations are conducted with meticulous consideration of key factors, such as fault type, fault resistance, fault location, fault inception angle, and power source angle. Simulation results demonstrate the effectiveness of the proposed protection scheme.</p>\n </div>","PeriodicalId":51293,"journal":{"name":"International Transactions on Electrical Energy Systems","volume":"2024 1","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2024/9100505","citationCount":"0","resultStr":"{\"title\":\"Enhancing Speed of Distance Protection for Internal Faults in the Second Zone through an Innovative Protection Algorithm\",\"authors\":\"Sabah Daniar, Mojtaba Shiroei, Amirhossein Khosravi Sarvenoee\",\"doi\":\"10.1155/2024/9100505\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n <p>Electric power systems constantly encounter disturbances and faults, necessitating fast and precise identification and rectification of these issues. This is crucial for ensuring the stability and reliability of the system. This paper introduces a protection scheme for accelerating the second zone operation of the distance relay during internal faults. The proposed scheme exploits the locus of power with positive power characteristics to effectively distinguish between internal and external faults. This is achieved by detecting the remote circuit breaker operation (RCBO). The locus of power remains predominantly within regions 1 or 2, with occasional transfers between these regions due to internal faults prior to and following the RCBO. Conversely, in the case of external faults, regions 3 or 4 are implicated. This distinct variation in the locus of power is applied to derive the protection algorithm. This is affirmed through sequence network analysis of various faults in the transmission line. The cumulative rate of change in relative reactive power has been employed for single-phase RCBO detection. The proposed protection logic employs supplementary undervoltage logic to avoid single-phase operation during two-phase and three-phase faults. The simulations are conducted with meticulous consideration of key factors, such as fault type, fault resistance, fault location, fault inception angle, and power source angle. Simulation results demonstrate the effectiveness of the proposed protection scheme.</p>\\n </div>\",\"PeriodicalId\":51293,\"journal\":{\"name\":\"International Transactions on Electrical Energy Systems\",\"volume\":\"2024 1\",\"pages\":\"\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2024/9100505\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Transactions on Electrical Energy Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1155/2024/9100505\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Transactions on Electrical Energy Systems","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/2024/9100505","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Enhancing Speed of Distance Protection for Internal Faults in the Second Zone through an Innovative Protection Algorithm
Electric power systems constantly encounter disturbances and faults, necessitating fast and precise identification and rectification of these issues. This is crucial for ensuring the stability and reliability of the system. This paper introduces a protection scheme for accelerating the second zone operation of the distance relay during internal faults. The proposed scheme exploits the locus of power with positive power characteristics to effectively distinguish between internal and external faults. This is achieved by detecting the remote circuit breaker operation (RCBO). The locus of power remains predominantly within regions 1 or 2, with occasional transfers between these regions due to internal faults prior to and following the RCBO. Conversely, in the case of external faults, regions 3 or 4 are implicated. This distinct variation in the locus of power is applied to derive the protection algorithm. This is affirmed through sequence network analysis of various faults in the transmission line. The cumulative rate of change in relative reactive power has been employed for single-phase RCBO detection. The proposed protection logic employs supplementary undervoltage logic to avoid single-phase operation during two-phase and three-phase faults. The simulations are conducted with meticulous consideration of key factors, such as fault type, fault resistance, fault location, fault inception angle, and power source angle. Simulation results demonstrate the effectiveness of the proposed protection scheme.
期刊介绍:
International Transactions on Electrical Energy Systems publishes original research results on key advances in the generation, transmission, and distribution of electrical energy systems. Of particular interest are submissions concerning the modeling, analysis, optimization and control of advanced electric power systems.
Manuscripts on topics of economics, finance, policies, insulation materials, low-voltage power electronics, plasmas, and magnetics will generally not be considered for review.