{"title":"胸部放射治疗过程中 X 光室的散射辐射水平","authors":"","doi":"10.1016/j.apradiso.2024.111472","DOIUrl":null,"url":null,"abstract":"<div><p>This research focused on the determination of scatter radiation levels in x-ray rooms during chest radiography. 108 patients were examined. Four x-ray machines (A, B, C, and D) were used during the research from three centers. Three positions were considered in this study; position Q just beside the (Bucky stand), position R, which is 150 cm from the left of the Bucky stand towards the door and position T, 200 cm from the Bucky stand to the radiographer's protective screen respectively. Two machines (A and B) from center 1 and one machine from center 2 (C) and one machine from center 3 (D). The body mass index (BMI) of the participants ranged from 20 to 25 kgm<sup>−2</sup> with mean value of 23.97 kgm<sup>−2</sup>. The background radiation level was read using Radalert 100 m before any exposure, and the mean background level was 0.298 mR/h. The mean of the scatter radiation doses obtained from positions Q with respect to the four machines A, B, C, and D, were 0.109, 0.201, 0.204, 0.200 mR/h (9.166, 16.903, 17.156, 16.819 mSv/yr) and their standard deviations were ±0.052, ±0.053, ±0.064, and ±0.081 respectively. The results were comparable with previous studies. The study recommends staff education and training in determination of radiation levels for enhanced work safety.</p></div>","PeriodicalId":8096,"journal":{"name":"Applied Radiation and Isotopes","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Scatter radiation levels in X-ray rooms during chest radiography\",\"authors\":\"\",\"doi\":\"10.1016/j.apradiso.2024.111472\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This research focused on the determination of scatter radiation levels in x-ray rooms during chest radiography. 108 patients were examined. Four x-ray machines (A, B, C, and D) were used during the research from three centers. Three positions were considered in this study; position Q just beside the (Bucky stand), position R, which is 150 cm from the left of the Bucky stand towards the door and position T, 200 cm from the Bucky stand to the radiographer's protective screen respectively. Two machines (A and B) from center 1 and one machine from center 2 (C) and one machine from center 3 (D). The body mass index (BMI) of the participants ranged from 20 to 25 kgm<sup>−2</sup> with mean value of 23.97 kgm<sup>−2</sup>. The background radiation level was read using Radalert 100 m before any exposure, and the mean background level was 0.298 mR/h. The mean of the scatter radiation doses obtained from positions Q with respect to the four machines A, B, C, and D, were 0.109, 0.201, 0.204, 0.200 mR/h (9.166, 16.903, 17.156, 16.819 mSv/yr) and their standard deviations were ±0.052, ±0.053, ±0.064, and ±0.081 respectively. The results were comparable with previous studies. The study recommends staff education and training in determination of radiation levels for enhanced work safety.</p></div>\",\"PeriodicalId\":8096,\"journal\":{\"name\":\"Applied Radiation and Isotopes\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Radiation and Isotopes\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0969804324003002\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, INORGANIC & NUCLEAR\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Radiation and Isotopes","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0969804324003002","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
Scatter radiation levels in X-ray rooms during chest radiography
This research focused on the determination of scatter radiation levels in x-ray rooms during chest radiography. 108 patients were examined. Four x-ray machines (A, B, C, and D) were used during the research from three centers. Three positions were considered in this study; position Q just beside the (Bucky stand), position R, which is 150 cm from the left of the Bucky stand towards the door and position T, 200 cm from the Bucky stand to the radiographer's protective screen respectively. Two machines (A and B) from center 1 and one machine from center 2 (C) and one machine from center 3 (D). The body mass index (BMI) of the participants ranged from 20 to 25 kgm−2 with mean value of 23.97 kgm−2. The background radiation level was read using Radalert 100 m before any exposure, and the mean background level was 0.298 mR/h. The mean of the scatter radiation doses obtained from positions Q with respect to the four machines A, B, C, and D, were 0.109, 0.201, 0.204, 0.200 mR/h (9.166, 16.903, 17.156, 16.819 mSv/yr) and their standard deviations were ±0.052, ±0.053, ±0.064, and ±0.081 respectively. The results were comparable with previous studies. The study recommends staff education and training in determination of radiation levels for enhanced work safety.
期刊介绍:
Applied Radiation and Isotopes provides a high quality medium for the publication of substantial, original and scientific and technological papers on the development and peaceful application of nuclear, radiation and radionuclide techniques in chemistry, physics, biochemistry, biology, medicine, security, engineering and in the earth, planetary and environmental sciences, all including dosimetry. Nuclear techniques are defined in the broadest sense and both experimental and theoretical papers are welcome. They include the development and use of α- and β-particles, X-rays and γ-rays, neutrons and other nuclear particles and radiations from all sources, including radionuclides, synchrotron sources, cyclotrons and reactors and from the natural environment.
The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria.
Papers dealing with radiation processing, i.e., where radiation is used to bring about a biological, chemical or physical change in a material, should be directed to our sister journal Radiation Physics and Chemistry.