{"title":"调查一家学术医疗机构办公室的甲醛超标情况并确定来源。","authors":"Watcharakorn Chuthong, Vithawat Surawattanasakul, Ratana Sapbamrer, Wachiranun Sirikul","doi":"10.1093/joccuh/uiae049","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To investigate factors associated with indoor formaldehyde levels in office settings within an academic medical institute.</p><p><strong>Methods: </strong>This cross-sectional study was conducted in 25 offices (261 workers) at a medical university in Thailand. Questionnaires gathered data on demographics, work patterns, and office equipment usage (printers, photocopiers, air fresheners, liquid paper, glue, cleaning agents, and marker pens). The building environment was assessed by a multidisciplinary team. Formaldehyde levels and relevant parameters (temperature and relative humidity) were measured in each room both indoors and outdoors. A multiple linear regression model investigated the relationship between formaldehyde and office factors, controlling for room conditions.</p><p><strong>Results: </strong>Median office formaldehyde levels were 442.1 μg/m3 (interquartile range: 343.8-908.7 μg/m3), exceeding World Health Organization and Thai guidelines. Photocopier use was significantly associated with higher levels of indoor formaldehyde (β = .20; 95% CI, 0.30-0.37; P = .02). Air freshener use also showed a significant association (β = .56; 95% CI, 0.30-0.81; P < .001). No correlation was found between the use of liquid paper, glue, printers, cleaning agents, or marker pens and indoor formaldehyde levels.</p><p><strong>Conclusions: </strong>Indoor formaldehyde levels in these offices exceeded the established guidelines. Use of photocopiers and air fresheners was associated with increased formaldehyde levels. Implementing interventions such as improved ventilation and regular screening is essential for creating healthier office environments.</p>","PeriodicalId":16632,"journal":{"name":"Journal of Occupational Health","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11457052/pdf/","citationCount":"0","resultStr":"{\"title\":\"Investigating exceedances of formaldehyde levels and source identification in offices of an academic medical institute.\",\"authors\":\"Watcharakorn Chuthong, Vithawat Surawattanasakul, Ratana Sapbamrer, Wachiranun Sirikul\",\"doi\":\"10.1093/joccuh/uiae049\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To investigate factors associated with indoor formaldehyde levels in office settings within an academic medical institute.</p><p><strong>Methods: </strong>This cross-sectional study was conducted in 25 offices (261 workers) at a medical university in Thailand. Questionnaires gathered data on demographics, work patterns, and office equipment usage (printers, photocopiers, air fresheners, liquid paper, glue, cleaning agents, and marker pens). The building environment was assessed by a multidisciplinary team. Formaldehyde levels and relevant parameters (temperature and relative humidity) were measured in each room both indoors and outdoors. A multiple linear regression model investigated the relationship between formaldehyde and office factors, controlling for room conditions.</p><p><strong>Results: </strong>Median office formaldehyde levels were 442.1 μg/m3 (interquartile range: 343.8-908.7 μg/m3), exceeding World Health Organization and Thai guidelines. Photocopier use was significantly associated with higher levels of indoor formaldehyde (β = .20; 95% CI, 0.30-0.37; P = .02). Air freshener use also showed a significant association (β = .56; 95% CI, 0.30-0.81; P < .001). No correlation was found between the use of liquid paper, glue, printers, cleaning agents, or marker pens and indoor formaldehyde levels.</p><p><strong>Conclusions: </strong>Indoor formaldehyde levels in these offices exceeded the established guidelines. Use of photocopiers and air fresheners was associated with increased formaldehyde levels. Implementing interventions such as improved ventilation and regular screening is essential for creating healthier office environments.</p>\",\"PeriodicalId\":16632,\"journal\":{\"name\":\"Journal of Occupational Health\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-01-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11457052/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Occupational Health\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/joccuh/uiae049\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Occupational Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/joccuh/uiae049","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
Investigating exceedances of formaldehyde levels and source identification in offices of an academic medical institute.
Objectives: To investigate factors associated with indoor formaldehyde levels in office settings within an academic medical institute.
Methods: This cross-sectional study was conducted in 25 offices (261 workers) at a medical university in Thailand. Questionnaires gathered data on demographics, work patterns, and office equipment usage (printers, photocopiers, air fresheners, liquid paper, glue, cleaning agents, and marker pens). The building environment was assessed by a multidisciplinary team. Formaldehyde levels and relevant parameters (temperature and relative humidity) were measured in each room both indoors and outdoors. A multiple linear regression model investigated the relationship between formaldehyde and office factors, controlling for room conditions.
Results: Median office formaldehyde levels were 442.1 μg/m3 (interquartile range: 343.8-908.7 μg/m3), exceeding World Health Organization and Thai guidelines. Photocopier use was significantly associated with higher levels of indoor formaldehyde (β = .20; 95% CI, 0.30-0.37; P = .02). Air freshener use also showed a significant association (β = .56; 95% CI, 0.30-0.81; P < .001). No correlation was found between the use of liquid paper, glue, printers, cleaning agents, or marker pens and indoor formaldehyde levels.
Conclusions: Indoor formaldehyde levels in these offices exceeded the established guidelines. Use of photocopiers and air fresheners was associated with increased formaldehyde levels. Implementing interventions such as improved ventilation and regular screening is essential for creating healthier office environments.
期刊介绍:
The scope of the journal is broad, covering toxicology, ergonomics, psychosocial factors and other relevant health issues of workers, with special emphasis on the current developments in occupational health. The JOH also accepts various methodologies that are relevant to investigation of occupational health risk factors and exposures, such as large-scale epidemiological studies, human studies employing biological techniques and fundamental experiments on animals, and also welcomes submissions concerning occupational health practices and related issues.