解剖全肩关节成形术盂成形假体设计的进展。

IF 2.6 2区 医学 Q1 ORTHOPEDICS Journal of the American Academy of Orthopaedic Surgeons Pub Date : 2024-08-13 DOI:10.5435/JAAOS-D-23-00257
Melissa A Wright, Michael O'Leary, Peter Johnston, Anand M Murthi
{"title":"解剖全肩关节成形术盂成形假体设计的进展。","authors":"Melissa A Wright, Michael O'Leary, Peter Johnston, Anand M Murthi","doi":"10.5435/JAAOS-D-23-00257","DOIUrl":null,"url":null,"abstract":"<p><p>Since the advent of Neer's total shoulder arthroplasty in 1974, glenoid implant design has evolved to optimize patient function and increase implant longevity. Glenoid loosening continues to be a major cause of total shoulder arthroplasty failure due to both patient and implant factors. The more recent development of posterior augmented glenoids, peg fixation with ingrowth potential, inlay implants, zoned conformity implants, and convertible glenoids have all shown promising results in improving glenoid fixation and survival in different clinical circumstances. The increased utilization of 3D CT scans, preoperative planning, and patient-specific instrumentation has paralleled innovation in glenoid implants with the aim of improving the accuracy of glenoid implant placement to further optimize patient function and implant longevity. Specific indications for the variety of glenoid implants available today are still being studied. The shoulder arthroplasty surgeon should consider patient and implant factors and patient goals when determining the appropriate implant for each individual.</p>","PeriodicalId":51098,"journal":{"name":"Journal of the American Academy of Orthopaedic Surgeons","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Advances in Anatomic Total Shoulder Arthroplasty Glenoid Implant Design.\",\"authors\":\"Melissa A Wright, Michael O'Leary, Peter Johnston, Anand M Murthi\",\"doi\":\"10.5435/JAAOS-D-23-00257\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Since the advent of Neer's total shoulder arthroplasty in 1974, glenoid implant design has evolved to optimize patient function and increase implant longevity. Glenoid loosening continues to be a major cause of total shoulder arthroplasty failure due to both patient and implant factors. The more recent development of posterior augmented glenoids, peg fixation with ingrowth potential, inlay implants, zoned conformity implants, and convertible glenoids have all shown promising results in improving glenoid fixation and survival in different clinical circumstances. The increased utilization of 3D CT scans, preoperative planning, and patient-specific instrumentation has paralleled innovation in glenoid implants with the aim of improving the accuracy of glenoid implant placement to further optimize patient function and implant longevity. Specific indications for the variety of glenoid implants available today are still being studied. The shoulder arthroplasty surgeon should consider patient and implant factors and patient goals when determining the appropriate implant for each individual.</p>\",\"PeriodicalId\":51098,\"journal\":{\"name\":\"Journal of the American Academy of Orthopaedic Surgeons\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-08-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Academy of Orthopaedic Surgeons\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5435/JAAOS-D-23-00257\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Academy of Orthopaedic Surgeons","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5435/JAAOS-D-23-00257","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

自 1974 年 Neer 全肩关节成形术问世以来,盂成形假体的设计不断发展,以优化患者功能并延长假体寿命。由于患者和植入物两方面的因素,盂状关节松动仍然是全肩关节置换术失败的主要原因。最近开发的后方增量盂体、具有生长潜力的钉固定、镶嵌植入物、分区一致性植入物和可转换盂体在改善盂体固定和不同临床情况下的存活率方面都取得了可喜的成果。随着三维 CT 扫描、术前规划和患者专用器械使用率的提高,盂成形体植入物也在不断创新,其目的是提高盂成形体植入物放置的准确性,进一步优化患者功能和植入物的使用寿命。目前,人们仍在研究各种盂成形体植入物的具体适应症。肩关节外科医生在确定适合每个患者的植入物时,应考虑患者和植入物的因素以及患者的目标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Advances in Anatomic Total Shoulder Arthroplasty Glenoid Implant Design.

Since the advent of Neer's total shoulder arthroplasty in 1974, glenoid implant design has evolved to optimize patient function and increase implant longevity. Glenoid loosening continues to be a major cause of total shoulder arthroplasty failure due to both patient and implant factors. The more recent development of posterior augmented glenoids, peg fixation with ingrowth potential, inlay implants, zoned conformity implants, and convertible glenoids have all shown promising results in improving glenoid fixation and survival in different clinical circumstances. The increased utilization of 3D CT scans, preoperative planning, and patient-specific instrumentation has paralleled innovation in glenoid implants with the aim of improving the accuracy of glenoid implant placement to further optimize patient function and implant longevity. Specific indications for the variety of glenoid implants available today are still being studied. The shoulder arthroplasty surgeon should consider patient and implant factors and patient goals when determining the appropriate implant for each individual.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.10
自引率
6.20%
发文量
529
审稿时长
4-8 weeks
期刊介绍: The Journal of the American Academy of Orthopaedic Surgeons was established in the fall of 1993 by the Academy in response to its membership’s demand for a clinical review journal. Two issues were published the first year, followed by six issues yearly from 1994 through 2004. In September 2005, JAAOS began publishing monthly issues. Each issue includes richly illustrated peer-reviewed articles focused on clinical diagnosis and management. Special features in each issue provide commentary on developments in pharmacotherapeutics, materials and techniques, and computer applications.
期刊最新文献
Understanding the Influence of Single Payer Health Insurance on Socioeconomic Disparities in Total Hip Arthroplasty (THA) Utilization: A Transnational Analysis. Patellofemoral Instability Part II: Surgical Treatment. American Academy of Orthopaedic Surgeons Clinical Practice Guideline Summary Management of Osteoarthritis of the Hip. Femoral Head Fractures: Evaluation, Management, and Outcomes. Trends in Preoperative Outcome Measures From 2013 to 2021 in Patients Undergoing Primary Total Joint Arthroplasty.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1