AMS-700 CXR充气式阴茎假体在高危阴茎纤维化患者中的长期使用经验。

IF 2.8 3区 医学 Q2 UROLOGY & NEPHROLOGY International Journal of Impotence Research Pub Date : 2024-08-17 DOI:10.1038/s41443-024-00962-y
Blake E Johnson, Brian T Langford, Maia E VanDyke, Ethan L Matz, Grayden S Cook, Bryce P Franzen, Allen F Morey
{"title":"AMS-700 CXR充气式阴茎假体在高危阴茎纤维化患者中的长期使用经验。","authors":"Blake E Johnson, Brian T Langford, Maia E VanDyke, Ethan L Matz, Grayden S Cook, Bryce P Franzen, Allen F Morey","doi":"10.1038/s41443-024-00962-y","DOIUrl":null,"url":null,"abstract":"<p><p>Despite the widespread use of narrow diameter inflatable penile prosthesis (IPP) cylinders in patients with corporal fibrosis, outcomes data is sparse. We evaluated patients who underwent IPP placement with AMS™ 700 Controlled Expansion Restricted (CXR) cylinders from 2007-2021. Patient characteristics, device details, and surgical outcomes were assessed. A non-validated questionnaire was also distributed to patients to assess satisfaction. Among 982 IPPs placed over the study period at our institution, 49 (5.0%) used CXR cylinders. Indications for narrow cylinders: prior explant for infection (67.3%), ischemic priapism (16.3%), and idiopathic fibrosis (16.3%). Median corporal length was 19 cm (IQR 17-21 cm). Discordant intraoperative corporal measurements (24.5%) and RTE lengths (26.5%) were common. Post-operative complications occurred in 8 patients (16.3%) and included 3 infections (6.1%), 2 cylinder herniations (4.1%), 2 mechanical failures (4.1%), and one case of glans necrosis (2.0%). Five of these (10.2%) required explantation, while 4 (8.2%) were managed with revision. Over the follow-up period, 73.5% of patients reported satisfaction with rigidity. Primary drivers of dissatisfaction were perceived loss of penile length and girth. The AMS™ 700 CXR is a useful tool for challenging corporal fibrosis cases and shows acceptable surgical outcomes with moderate patient acceptability.</p>","PeriodicalId":14068,"journal":{"name":"International Journal of Impotence Research","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Long-term experience with AMS-700 CXR inflatable penile prosthesis in high-risk patients with corporal fibrosis.\",\"authors\":\"Blake E Johnson, Brian T Langford, Maia E VanDyke, Ethan L Matz, Grayden S Cook, Bryce P Franzen, Allen F Morey\",\"doi\":\"10.1038/s41443-024-00962-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Despite the widespread use of narrow diameter inflatable penile prosthesis (IPP) cylinders in patients with corporal fibrosis, outcomes data is sparse. We evaluated patients who underwent IPP placement with AMS™ 700 Controlled Expansion Restricted (CXR) cylinders from 2007-2021. Patient characteristics, device details, and surgical outcomes were assessed. A non-validated questionnaire was also distributed to patients to assess satisfaction. Among 982 IPPs placed over the study period at our institution, 49 (5.0%) used CXR cylinders. Indications for narrow cylinders: prior explant for infection (67.3%), ischemic priapism (16.3%), and idiopathic fibrosis (16.3%). Median corporal length was 19 cm (IQR 17-21 cm). Discordant intraoperative corporal measurements (24.5%) and RTE lengths (26.5%) were common. Post-operative complications occurred in 8 patients (16.3%) and included 3 infections (6.1%), 2 cylinder herniations (4.1%), 2 mechanical failures (4.1%), and one case of glans necrosis (2.0%). Five of these (10.2%) required explantation, while 4 (8.2%) were managed with revision. Over the follow-up period, 73.5% of patients reported satisfaction with rigidity. Primary drivers of dissatisfaction were perceived loss of penile length and girth. The AMS™ 700 CXR is a useful tool for challenging corporal fibrosis cases and shows acceptable surgical outcomes with moderate patient acceptability.</p>\",\"PeriodicalId\":14068,\"journal\":{\"name\":\"International Journal of Impotence Research\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-08-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Impotence Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1038/s41443-024-00962-y\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Impotence Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1038/s41443-024-00962-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

尽管窄直径充气阴茎假体(IPP)钢瓶在体腔纤维化患者中得到了广泛应用,但疗效数据却很少。我们对 2007-2021 年间使用 AMS™ 700 受控膨胀限制(CXR)圆柱进行 IPP 置入手术的患者进行了评估。我们对患者特征、设备详情和手术结果进行了评估。此外,还向患者发放了一份未经验证的调查问卷,以评估满意度。在研究期间,我院共放置了 982 个 IPP,其中 49 个(5.0%)使用了 CXR 气瓶。使用窄圆柱的适应症包括:因感染(67.3%)、缺血性前列腺增生症(16.3%)和特发性纤维化(16.3%)导致的前列腺切除。体腔长度中位数为 19 厘米(IQR 17-21 厘米)。术中下体测量值(24.5%)和RTE长度(26.5%)不一致的情况很常见。8名患者(16.3%)出现了术后并发症,包括3例感染(6.1%)、2例圆柱疝(4.1%)、2例机械故障(4.1%)和1例龟头坏死(2.0%)。其中 5 例(10.2%)需要更换,4 例(8.2%)进行了翻修。在随访期间,73.5% 的患者对阴茎硬度表示满意。不满意的主要原因是认为阴茎长度和周长有所减少。AMS™ 700 CXR 是治疗具有挑战性的阴茎纤维化病例的有用工具,其手术效果可接受,患者接受度适中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Long-term experience with AMS-700 CXR inflatable penile prosthesis in high-risk patients with corporal fibrosis.

Despite the widespread use of narrow diameter inflatable penile prosthesis (IPP) cylinders in patients with corporal fibrosis, outcomes data is sparse. We evaluated patients who underwent IPP placement with AMS™ 700 Controlled Expansion Restricted (CXR) cylinders from 2007-2021. Patient characteristics, device details, and surgical outcomes were assessed. A non-validated questionnaire was also distributed to patients to assess satisfaction. Among 982 IPPs placed over the study period at our institution, 49 (5.0%) used CXR cylinders. Indications for narrow cylinders: prior explant for infection (67.3%), ischemic priapism (16.3%), and idiopathic fibrosis (16.3%). Median corporal length was 19 cm (IQR 17-21 cm). Discordant intraoperative corporal measurements (24.5%) and RTE lengths (26.5%) were common. Post-operative complications occurred in 8 patients (16.3%) and included 3 infections (6.1%), 2 cylinder herniations (4.1%), 2 mechanical failures (4.1%), and one case of glans necrosis (2.0%). Five of these (10.2%) required explantation, while 4 (8.2%) were managed with revision. Over the follow-up period, 73.5% of patients reported satisfaction with rigidity. Primary drivers of dissatisfaction were perceived loss of penile length and girth. The AMS™ 700 CXR is a useful tool for challenging corporal fibrosis cases and shows acceptable surgical outcomes with moderate patient acceptability.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Impotence Research
International Journal of Impotence Research 医学-泌尿学与肾脏学
CiteScore
4.90
自引率
19.20%
发文量
140
审稿时长
>12 weeks
期刊介绍: International Journal of Impotence Research: The Journal of Sexual Medicine addresses sexual medicine for both genders as an interdisciplinary field. This includes basic science researchers, urologists, endocrinologists, cardiologists, family practitioners, gynecologists, internists, neurologists, psychiatrists, psychologists, radiologists and other health care clinicians.
期刊最新文献
Melatonin and erectile dysfunction: addressing research gaps and proposing future investigations. Sympathetic hypoactivity leads to hypocontractility of the corpus cavernosum in sickle cell mice: a mechanism contributing to priapism. Priapism in the paediatric and adolescent population. Inflatable penile prosthesis implantation in the outpatient setting is safe and feasible: a prospective, singe center study. Patients' perceptions of nocturnal erectile function assessment with the RigiScan®.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1