用 82 铷正电子发射计算机断层成像技术评估肾功能正常和异常患者的肾脏灌注情况。

IF 1.3 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Nuclear Medicine Communications Pub Date : 2024-11-01 Epub Date: 2024-08-19 DOI:10.1097/MNM.0000000000001890
Alexandre Bibeau-Delisle, Nadia Bouabdallaoui, Caroline Lamarche, Francois Harel, Matthieu Pelletier-Galarneau
{"title":"用 82 铷正电子发射计算机断层成像技术评估肾功能正常和异常患者的肾脏灌注情况。","authors":"Alexandre Bibeau-Delisle, Nadia Bouabdallaoui, Caroline Lamarche, Francois Harel, Matthieu Pelletier-Galarneau","doi":"10.1097/MNM.0000000000001890","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Noninvasive measurement of renal blood flow (RBF) and renal vascular resistance (RVR) is challenging, yet critical in renal pathologies. This study evaluates the correlation between serum renal function markers and RBF/RVR assessed using rubidium PET.</p><p><strong>Methods: </strong>Dynamic images from 53 patients who underwent rubidium PET for nonrenal indications were analyzed. RBF was determined using a one-compartment model, and RVR was calculated by dividing mean arterial pressure by RBF.</p><p><strong>Results: </strong>The study included 51 patients (31 females and 20 males). Among them, 35 had normal renal function [estimated glomerular filtration rate (eGFR) ≥60 ml/min/1.73 m 2 ], and 16 had abnormal renal function (eGFR <60 ml/min/1.73 m 2 ). Patients with normal renal function had significantly higher RBF [median (interquartile range): 443 (297-722) vs 173 (108-380) ml/min/100 g, P  = 0.022] and lower RVR [19.1 (12.4-27.2) vs 49.6 (24.4-85.7) mmHg×min×g/ml, P  = 0.0011) compared with those with abnormal renal function. There was a moderate correlation between RBF and eGFR ( r  = 0.62, P  < 0.0001) and between RVR and eGFR ( r  = -0.59, P  < 0.0001) in both groups. Among patients with normal renal function, RBF was negatively correlated with age ( r  = -0.51, P  = 0.0017) but there was no correlation among patients with abnormal renal function ( r  = 0.21, P  = 0.44).</p><p><strong>Conclusion: </strong>PET-measured RBF and RVR correlate with renal function markers and differ significantly by renal function status. Further studies are needed to validate rubidium PET's precision and clinical applicability.</p>","PeriodicalId":19708,"journal":{"name":"Nuclear Medicine Communications","volume":" ","pages":"958-962"},"PeriodicalIF":1.3000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of renal perfusion with 82-rubidium PET in patients with normal and abnormal renal function.\",\"authors\":\"Alexandre Bibeau-Delisle, Nadia Bouabdallaoui, Caroline Lamarche, Francois Harel, Matthieu Pelletier-Galarneau\",\"doi\":\"10.1097/MNM.0000000000001890\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Noninvasive measurement of renal blood flow (RBF) and renal vascular resistance (RVR) is challenging, yet critical in renal pathologies. This study evaluates the correlation between serum renal function markers and RBF/RVR assessed using rubidium PET.</p><p><strong>Methods: </strong>Dynamic images from 53 patients who underwent rubidium PET for nonrenal indications were analyzed. RBF was determined using a one-compartment model, and RVR was calculated by dividing mean arterial pressure by RBF.</p><p><strong>Results: </strong>The study included 51 patients (31 females and 20 males). Among them, 35 had normal renal function [estimated glomerular filtration rate (eGFR) ≥60 ml/min/1.73 m 2 ], and 16 had abnormal renal function (eGFR <60 ml/min/1.73 m 2 ). Patients with normal renal function had significantly higher RBF [median (interquartile range): 443 (297-722) vs 173 (108-380) ml/min/100 g, P  = 0.022] and lower RVR [19.1 (12.4-27.2) vs 49.6 (24.4-85.7) mmHg×min×g/ml, P  = 0.0011) compared with those with abnormal renal function. There was a moderate correlation between RBF and eGFR ( r  = 0.62, P  < 0.0001) and between RVR and eGFR ( r  = -0.59, P  < 0.0001) in both groups. Among patients with normal renal function, RBF was negatively correlated with age ( r  = -0.51, P  = 0.0017) but there was no correlation among patients with abnormal renal function ( r  = 0.21, P  = 0.44).</p><p><strong>Conclusion: </strong>PET-measured RBF and RVR correlate with renal function markers and differ significantly by renal function status. Further studies are needed to validate rubidium PET's precision and clinical applicability.</p>\",\"PeriodicalId\":19708,\"journal\":{\"name\":\"Nuclear Medicine Communications\",\"volume\":\" \",\"pages\":\"958-962\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Medicine Communications\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MNM.0000000000001890\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Medicine Communications","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MNM.0000000000001890","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/19 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:肾血流(RBF)和肾血管阻力(RVR)的无创测量具有挑战性,但对肾脏病变却至关重要。本研究评估了血清肾功能标记物与使用铷正电子发射计算机断层显像技术评估的 RBF/RVR 之间的相关性:方法:分析了 53 例因非肾脏疾病接受铷正电子发射计算机断层显像的患者的动态图像。采用单室模型确定 RBF,用平均动脉压除以 RBF 计算 RVR:研究共纳入 51 名患者(31 名女性和 20 名男性)。其中 35 人肾功能正常[估计肾小球滤过率(eGFR)≥60 ml/min/1.73 m2],16 人肾功能异常(eGFR 结论):PET 测量的 RBF 和 RVR 与肾功能标志物相关,并因肾功能状态而有显著差异。还需要进一步的研究来验证铷PET的精确性和临床适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of renal perfusion with 82-rubidium PET in patients with normal and abnormal renal function.

Background: Noninvasive measurement of renal blood flow (RBF) and renal vascular resistance (RVR) is challenging, yet critical in renal pathologies. This study evaluates the correlation between serum renal function markers and RBF/RVR assessed using rubidium PET.

Methods: Dynamic images from 53 patients who underwent rubidium PET for nonrenal indications were analyzed. RBF was determined using a one-compartment model, and RVR was calculated by dividing mean arterial pressure by RBF.

Results: The study included 51 patients (31 females and 20 males). Among them, 35 had normal renal function [estimated glomerular filtration rate (eGFR) ≥60 ml/min/1.73 m 2 ], and 16 had abnormal renal function (eGFR <60 ml/min/1.73 m 2 ). Patients with normal renal function had significantly higher RBF [median (interquartile range): 443 (297-722) vs 173 (108-380) ml/min/100 g, P  = 0.022] and lower RVR [19.1 (12.4-27.2) vs 49.6 (24.4-85.7) mmHg×min×g/ml, P  = 0.0011) compared with those with abnormal renal function. There was a moderate correlation between RBF and eGFR ( r  = 0.62, P  < 0.0001) and between RVR and eGFR ( r  = -0.59, P  < 0.0001) in both groups. Among patients with normal renal function, RBF was negatively correlated with age ( r  = -0.51, P  = 0.0017) but there was no correlation among patients with abnormal renal function ( r  = 0.21, P  = 0.44).

Conclusion: PET-measured RBF and RVR correlate with renal function markers and differ significantly by renal function status. Further studies are needed to validate rubidium PET's precision and clinical applicability.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.20
自引率
6.70%
发文量
212
审稿时长
3-8 weeks
期刊介绍: Nuclear Medicine Communications, the official journal of the British Nuclear Medicine Society, is a rapid communications journal covering nuclear medicine and molecular imaging with radionuclides, and the basic supporting sciences. As well as clinical research and commentary, manuscripts describing research on preclinical and basic sciences (radiochemistry, radiopharmacy, radiobiology, radiopharmacology, medical physics, computing and engineering, and technical and nursing professions involved in delivering nuclear medicine services) are welcomed, as the journal is intended to be of interest internationally to all members of the many medical and non-medical disciplines involved in nuclear medicine. In addition to papers reporting original studies, frankly written editorials and topical reviews are a regular feature of the journal.
期刊最新文献
Correlation between 18 F-FDG PET/CT metabolic parameters and microvascular invasion before liver transplantation in patients with hepatocellular carcinoma. Evaluation of jaw pathologies of patients with medication-related osteonecrosis of the jaw using a computer program to assess the bone scan index: comparison of standardized uptake values with bone SPECT/CT. Parametric imaging in salivary gland scintigraphy. Predicting invasiveness of ground-glass nodules in lung adenocarcinoma: based on preoperative 18 F-fluorodeoxyglucose PET/computed tomography and high-resolution computed tomography. SeHCAT retention measurements may be compromised by traces of 177 Lu/ 177m Lu more than 90 days after 177 Lu-DOTATATE was administered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1