Eunhye Bae, Hyeontaek Hwang, Joong-Yub Kim, Young Sik Park, Jaeyoung Cho
{"title":"放射探头支气管内超声引导下经支气管活检的安全性和出血并发症的风险因素。","authors":"Eunhye Bae, Hyeontaek Hwang, Joong-Yub Kim, Young Sik Park, Jaeyoung Cho","doi":"10.1177/17534666241273017","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Radial probe endobronchial ultrasound (radial EBUS) is widely used to diagnose pulmonary lesions; however, the diagnostic value of radial EBUS-guided transbronchial biopsy (TBB) varies, and its complications (especially the risk of bleeding) are not properly understood.</p><p><strong>Objectives: </strong>In this study, we evaluated the diagnostic performance and rate of complication of this procedure, and investigated the risk factors associated with the procedure-related bleeding events.</p><p><strong>Design: </strong>A retrospective cohort study.</p><p><strong>Methods: </strong>This was a retrospective study that included consecutive patients who underwent radial EBUS-guided TBB. Radial EBUS was performed under moderate sedation in inpatients or outpatients. The severity of bleeding was graded using the standardized definitions of bleeding.</p><p><strong>Results: </strong>Of 133 patients (median age, 69 years; men 57.1%) included, 41 were outpatients (30.8%). The diagnostic accuracy, sensitivity, and specificity for malignancy were 76.1% (89/117), 71.1% (69/97), and 100% (20/20), respectively. The diagnostic accuracy ranged from 66.9% to 79.0%, depending on the classification of undiagnosed cases as either false negatives or true negatives. Twenty-seven patients (20.3%) developed complications (pneumothorax, 3; pneumonia, 5; complicated pleural effusion, 2; bleeding event grade 2 or higher, 21). Of the 41 outpatients, two developed complications (pneumothorax without intervention, 1; grade 2 bleeding event, 1). Of the 21 patients (15.8%) with procedure-related bleeding events, 18 had grade 2, and three had grade 3 bleeding complications. In multivariate analysis, a large size of ⩾30 mm (adjusted odds ratio (OR), 5.09; <i>p</i> = 0.03) and central lesion (adjusted OR, 3.67; <i>p</i> = 0.03) were significantly associated with the risk of grade 2 or higher bleeding events.</p><p><strong>Conclusion: </strong>Our results suggest that radial EBUS-guided TBB is an accurate and safe method for diagnosing pulmonary lesions. Clinically significant procedure-related bleeding was rare. The central location and larger size (⩾30 mm) of pulmonary lesions were risk factors for grade 2 or higher bleeding events.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11334151/pdf/","citationCount":"0","resultStr":"{\"title\":\"Safety and risk factors for bleeding complications of radial probe endobronchial ultrasound-guided transbronchial biopsy.\",\"authors\":\"Eunhye Bae, Hyeontaek Hwang, Joong-Yub Kim, Young Sik Park, Jaeyoung Cho\",\"doi\":\"10.1177/17534666241273017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Radial probe endobronchial ultrasound (radial EBUS) is widely used to diagnose pulmonary lesions; however, the diagnostic value of radial EBUS-guided transbronchial biopsy (TBB) varies, and its complications (especially the risk of bleeding) are not properly understood.</p><p><strong>Objectives: </strong>In this study, we evaluated the diagnostic performance and rate of complication of this procedure, and investigated the risk factors associated with the procedure-related bleeding events.</p><p><strong>Design: </strong>A retrospective cohort study.</p><p><strong>Methods: </strong>This was a retrospective study that included consecutive patients who underwent radial EBUS-guided TBB. Radial EBUS was performed under moderate sedation in inpatients or outpatients. The severity of bleeding was graded using the standardized definitions of bleeding.</p><p><strong>Results: </strong>Of 133 patients (median age, 69 years; men 57.1%) included, 41 were outpatients (30.8%). The diagnostic accuracy, sensitivity, and specificity for malignancy were 76.1% (89/117), 71.1% (69/97), and 100% (20/20), respectively. The diagnostic accuracy ranged from 66.9% to 79.0%, depending on the classification of undiagnosed cases as either false negatives or true negatives. Twenty-seven patients (20.3%) developed complications (pneumothorax, 3; pneumonia, 5; complicated pleural effusion, 2; bleeding event grade 2 or higher, 21). Of the 41 outpatients, two developed complications (pneumothorax without intervention, 1; grade 2 bleeding event, 1). Of the 21 patients (15.8%) with procedure-related bleeding events, 18 had grade 2, and three had grade 3 bleeding complications. In multivariate analysis, a large size of ⩾30 mm (adjusted odds ratio (OR), 5.09; <i>p</i> = 0.03) and central lesion (adjusted OR, 3.67; <i>p</i> = 0.03) were significantly associated with the risk of grade 2 or higher bleeding events.</p><p><strong>Conclusion: </strong>Our results suggest that radial EBUS-guided TBB is an accurate and safe method for diagnosing pulmonary lesions. Clinically significant procedure-related bleeding was rare. The central location and larger size (⩾30 mm) of pulmonary lesions were risk factors for grade 2 or higher bleeding events.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11334151/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/17534666241273017\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17534666241273017","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Safety and risk factors for bleeding complications of radial probe endobronchial ultrasound-guided transbronchial biopsy.
Background: Radial probe endobronchial ultrasound (radial EBUS) is widely used to diagnose pulmonary lesions; however, the diagnostic value of radial EBUS-guided transbronchial biopsy (TBB) varies, and its complications (especially the risk of bleeding) are not properly understood.
Objectives: In this study, we evaluated the diagnostic performance and rate of complication of this procedure, and investigated the risk factors associated with the procedure-related bleeding events.
Design: A retrospective cohort study.
Methods: This was a retrospective study that included consecutive patients who underwent radial EBUS-guided TBB. Radial EBUS was performed under moderate sedation in inpatients or outpatients. The severity of bleeding was graded using the standardized definitions of bleeding.
Results: Of 133 patients (median age, 69 years; men 57.1%) included, 41 were outpatients (30.8%). The diagnostic accuracy, sensitivity, and specificity for malignancy were 76.1% (89/117), 71.1% (69/97), and 100% (20/20), respectively. The diagnostic accuracy ranged from 66.9% to 79.0%, depending on the classification of undiagnosed cases as either false negatives or true negatives. Twenty-seven patients (20.3%) developed complications (pneumothorax, 3; pneumonia, 5; complicated pleural effusion, 2; bleeding event grade 2 or higher, 21). Of the 41 outpatients, two developed complications (pneumothorax without intervention, 1; grade 2 bleeding event, 1). Of the 21 patients (15.8%) with procedure-related bleeding events, 18 had grade 2, and three had grade 3 bleeding complications. In multivariate analysis, a large size of ⩾30 mm (adjusted odds ratio (OR), 5.09; p = 0.03) and central lesion (adjusted OR, 3.67; p = 0.03) were significantly associated with the risk of grade 2 or higher bleeding events.
Conclusion: Our results suggest that radial EBUS-guided TBB is an accurate and safe method for diagnosing pulmonary lesions. Clinically significant procedure-related bleeding was rare. The central location and larger size (⩾30 mm) of pulmonary lesions were risk factors for grade 2 or higher bleeding events.