Asif Iqbal, Damien Fisher, David Alonso-Caneiro, Michael J Collins, Stephen J Vincent
{"title":"角膜中央和周边对短期缺氧的反应。","authors":"Asif Iqbal, Damien Fisher, David Alonso-Caneiro, Michael J Collins, Stephen J Vincent","doi":"10.1111/opo.13380","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To quantify the magnitude and recovery of central and limbal corneal oedema induced by short-term unilateral eyelid closure without contact lens wear.</p><p><strong>Methods: </strong>The left eye of 10 adults with healthy corneas was patched using a folded eye pad for 30 min. High-resolution optical coherence tomography images (which captured the limbal and central corneal regions simultaneously) were obtained before patching, immediately after eye opening and again at 1, 2, 5, 6, 9, 10, 14 and 15 mins after eyelid opening. Oedema was measured from the limbus (scleral spur) to the central cornea (thinnest corneal location) along the horizontal meridian.</p><p><strong>Results: </strong>A greater amount of limbal oedema was noted (mean [SD] 3.84 [1.79] %) compared to the central cornea (2.48 [0.61] %; p = 0.04) after 30 mins of unilateral eyelid closure. Both central and limbal corneal oedema recovered rapidly following eyelid opening, with no significant differences in the rate of corneal recovery between corneal locations (p = 0.90).</p><p><strong>Conclusions: </strong>Short-term unilateral eyelid closure resulted in ~55% more relative oedema in the limbal region compared to the central cornea. Rapid recovery of oedema and corneal overshoot (thinning beyond the baseline corneal thickness) was observed within 1-2 min of eyelid opening for both central and peripheral regions.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The central and peripheral corneal response to short-term hypoxia.\",\"authors\":\"Asif Iqbal, Damien Fisher, David Alonso-Caneiro, Michael J Collins, Stephen J Vincent\",\"doi\":\"10.1111/opo.13380\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To quantify the magnitude and recovery of central and limbal corneal oedema induced by short-term unilateral eyelid closure without contact lens wear.</p><p><strong>Methods: </strong>The left eye of 10 adults with healthy corneas was patched using a folded eye pad for 30 min. High-resolution optical coherence tomography images (which captured the limbal and central corneal regions simultaneously) were obtained before patching, immediately after eye opening and again at 1, 2, 5, 6, 9, 10, 14 and 15 mins after eyelid opening. Oedema was measured from the limbus (scleral spur) to the central cornea (thinnest corneal location) along the horizontal meridian.</p><p><strong>Results: </strong>A greater amount of limbal oedema was noted (mean [SD] 3.84 [1.79] %) compared to the central cornea (2.48 [0.61] %; p = 0.04) after 30 mins of unilateral eyelid closure. Both central and limbal corneal oedema recovered rapidly following eyelid opening, with no significant differences in the rate of corneal recovery between corneal locations (p = 0.90).</p><p><strong>Conclusions: </strong>Short-term unilateral eyelid closure resulted in ~55% more relative oedema in the limbal region compared to the central cornea. Rapid recovery of oedema and corneal overshoot (thinning beyond the baseline corneal thickness) was observed within 1-2 min of eyelid opening for both central and peripheral regions.</p>\",\"PeriodicalId\":19522,\"journal\":{\"name\":\"Ophthalmic and Physiological Optics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmic and Physiological Optics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/opo.13380\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13380","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/20 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
The central and peripheral corneal response to short-term hypoxia.
Purpose: To quantify the magnitude and recovery of central and limbal corneal oedema induced by short-term unilateral eyelid closure without contact lens wear.
Methods: The left eye of 10 adults with healthy corneas was patched using a folded eye pad for 30 min. High-resolution optical coherence tomography images (which captured the limbal and central corneal regions simultaneously) were obtained before patching, immediately after eye opening and again at 1, 2, 5, 6, 9, 10, 14 and 15 mins after eyelid opening. Oedema was measured from the limbus (scleral spur) to the central cornea (thinnest corneal location) along the horizontal meridian.
Results: A greater amount of limbal oedema was noted (mean [SD] 3.84 [1.79] %) compared to the central cornea (2.48 [0.61] %; p = 0.04) after 30 mins of unilateral eyelid closure. Both central and limbal corneal oedema recovered rapidly following eyelid opening, with no significant differences in the rate of corneal recovery between corneal locations (p = 0.90).
Conclusions: Short-term unilateral eyelid closure resulted in ~55% more relative oedema in the limbal region compared to the central cornea. Rapid recovery of oedema and corneal overshoot (thinning beyond the baseline corneal thickness) was observed within 1-2 min of eyelid opening for both central and peripheral regions.
期刊介绍:
Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry.
OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.