机器人辅助经骨修复三角纤维软骨复合体:一项尸体研究。

IF 1.6 The Journal of hand surgery, European volume Pub Date : 2025-04-01 Epub Date: 2024-08-22 DOI:10.1177/17531934241263732
Zhixin Wang, Jiawen Wang, Qiuya Li, Yaobin Yin, Qianqian Wang, Shanlin Chen
{"title":"机器人辅助经骨修复三角纤维软骨复合体:一项尸体研究。","authors":"Zhixin Wang, Jiawen Wang, Qiuya Li, Yaobin Yin, Qianqian Wang, Shanlin Chen","doi":"10.1177/17531934241263732","DOIUrl":null,"url":null,"abstract":"<p><p>The feasibility and accuracy of robot-assisted bone tunnel construction in the transosseous repair of the triangular fibrocartilaginous complex (TFCC) were compared with those of freehand arthroscopic repair. A total of 20 cadaveric specimens were randomized into robotic-assisted and arthroscopy-guided groups. Three bone tunnels were constructed in the ulnar foveal region in each specimen. The discrepancy between the planned and actual tunnel exits was determined in the robot-assisted group by merging images. The success rate of tunnel construction, time consumption and number of drilling attempts were compared between groups. The median planned/actual exit discrepancy was 0.8 mm in the robot-assisted group, with 90% of tunnel exits successfully placed in the footprint region, compared to 63.3% in the arthroscopy-guided group. The robot-assisted group spent less time and required fewer drilling attempts to construct bone tunnels. These results indicated that the robot-assisted technique can accurately construct multiple bone tunnels in the foveal region and reduce the difficulty of TFCC transosseous repair.<b>Level of evidence:</b> III.</p>","PeriodicalId":94237,"journal":{"name":"The Journal of hand surgery, European volume","volume":" ","pages":"508-514"},"PeriodicalIF":1.6000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Robot-assisted transosseous repair of triangular fibrocartilage complex: a cadaver study.\",\"authors\":\"Zhixin Wang, Jiawen Wang, Qiuya Li, Yaobin Yin, Qianqian Wang, Shanlin Chen\",\"doi\":\"10.1177/17531934241263732\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The feasibility and accuracy of robot-assisted bone tunnel construction in the transosseous repair of the triangular fibrocartilaginous complex (TFCC) were compared with those of freehand arthroscopic repair. A total of 20 cadaveric specimens were randomized into robotic-assisted and arthroscopy-guided groups. Three bone tunnels were constructed in the ulnar foveal region in each specimen. The discrepancy between the planned and actual tunnel exits was determined in the robot-assisted group by merging images. The success rate of tunnel construction, time consumption and number of drilling attempts were compared between groups. The median planned/actual exit discrepancy was 0.8 mm in the robot-assisted group, with 90% of tunnel exits successfully placed in the footprint region, compared to 63.3% in the arthroscopy-guided group. The robot-assisted group spent less time and required fewer drilling attempts to construct bone tunnels. These results indicated that the robot-assisted technique can accurately construct multiple bone tunnels in the foveal region and reduce the difficulty of TFCC transosseous repair.<b>Level of evidence:</b> III.</p>\",\"PeriodicalId\":94237,\"journal\":{\"name\":\"The Journal of hand surgery, European volume\",\"volume\":\" \",\"pages\":\"508-514\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of hand surgery, European volume\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/17531934241263732\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of hand surgery, European volume","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17531934241263732","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/22 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在经骨修复三角纤维软骨复合体(TFCC)的过程中,比较了机器人辅助骨隧道构建的可行性和准确性,以及徒手关节镜修复的可行性和准确性。共有 20 具尸体标本被随机分为机器人辅助组和关节镜引导组。每个标本的尺骨窝区都建有三个骨隧道。在机器人辅助组中,通过合并图像来确定计划和实际隧道出口之间的差异。比较各组的隧道建造成功率、耗时和钻孔次数。机器人辅助组的计划/实际出口差异中位数为0.8毫米,90%的隧道出口成功位于足底区域,而关节镜引导组为63.3%。机器人辅助组建造骨隧道所花费的时间更短,所需的钻孔次数更少。这些结果表明,机器人辅助技术可以准确地在窝区构建多个骨隧道,降低TFCC经骨修复的难度:证据等级:III。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Robot-assisted transosseous repair of triangular fibrocartilage complex: a cadaver study.

The feasibility and accuracy of robot-assisted bone tunnel construction in the transosseous repair of the triangular fibrocartilaginous complex (TFCC) were compared with those of freehand arthroscopic repair. A total of 20 cadaveric specimens were randomized into robotic-assisted and arthroscopy-guided groups. Three bone tunnels were constructed in the ulnar foveal region in each specimen. The discrepancy between the planned and actual tunnel exits was determined in the robot-assisted group by merging images. The success rate of tunnel construction, time consumption and number of drilling attempts were compared between groups. The median planned/actual exit discrepancy was 0.8 mm in the robot-assisted group, with 90% of tunnel exits successfully placed in the footprint region, compared to 63.3% in the arthroscopy-guided group. The robot-assisted group spent less time and required fewer drilling attempts to construct bone tunnels. These results indicated that the robot-assisted technique can accurately construct multiple bone tunnels in the foveal region and reduce the difficulty of TFCC transosseous repair.Level of evidence: III.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative outcomes of single versus multiple trigger finger releases: a propensity score matched cohort study. Systematic characterization of flexor tendon and tendon sheath malposition in proximal phalangeal thumb polydactyly. Functional outcomes after open versus endoscopic-assisted De Quervain's release. Finger flexion after amputation through the proximal phalanx with and without flexor digitorum superficialis tenodesis. Surface alterations and chondrocyte activity in articular cartilage after monopolar radiofrequency treatment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1