使用超声波预测桡骨远端前方锁定钢板术后的屈肌腱病变。

Lea Estermann, Matthew Donaldson, Milos Spasojevic, Brett Lurie, Brahman Sivakumar, James Ledgard, Mark Hile
{"title":"使用超声波预测桡骨远端前方锁定钢板术后的屈肌腱病变。","authors":"Lea Estermann, Matthew Donaldson, Milos Spasojevic, Brett Lurie, Brahman Sivakumar, James Ledgard, Mark Hile","doi":"10.1177/17531934241268971","DOIUrl":null,"url":null,"abstract":"<p><p>This study compares ultrasound to clinical and radiographic measurements for assessing tendon pathology associated with distal radial anterior locking plates. A total of 46 patients undergoing removal of a distal radial plate had a preoperative clinical examination, radiographs and ultrasound evaluation to detect evidence of tendon irritation. Gross changes to the tendon were assessed during plate removal. In total, 32 patients demonstrated clinical abnormality. Soong 2 position was noted in 13 patients. Ultrasound revealed tenosynovitis in nine patients, tendon fibrillation or thickening in four patients and a single case of partial discontinuity. Intraoperative assessment revealed tenosynovitis in 28 patients and tendon fibre discontinuity in eight patients. Ultrasound findings were not predictive of intraoperative tenosynovitis and discontinuity. A relationship was noted between higher Soong grade, especially grade 2, and intraoperative presence of tenosynovitis, as well as Soong grade and amount of soft-tissue coverage. This study negates our hypothesis that ultrasound is useful for identifying tendinopathy after distal radial anterior plate fixation.<b>Level of evidence:</b> II.</p>","PeriodicalId":94237,"journal":{"name":"The Journal of hand surgery, European volume","volume":" ","pages":"17531934241268971"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The use of ultrasound to predict flexor tendinopathy after anterior locking plating of the distal radius.\",\"authors\":\"Lea Estermann, Matthew Donaldson, Milos Spasojevic, Brett Lurie, Brahman Sivakumar, James Ledgard, Mark Hile\",\"doi\":\"10.1177/17531934241268971\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study compares ultrasound to clinical and radiographic measurements for assessing tendon pathology associated with distal radial anterior locking plates. A total of 46 patients undergoing removal of a distal radial plate had a preoperative clinical examination, radiographs and ultrasound evaluation to detect evidence of tendon irritation. Gross changes to the tendon were assessed during plate removal. In total, 32 patients demonstrated clinical abnormality. Soong 2 position was noted in 13 patients. Ultrasound revealed tenosynovitis in nine patients, tendon fibrillation or thickening in four patients and a single case of partial discontinuity. Intraoperative assessment revealed tenosynovitis in 28 patients and tendon fibre discontinuity in eight patients. Ultrasound findings were not predictive of intraoperative tenosynovitis and discontinuity. A relationship was noted between higher Soong grade, especially grade 2, and intraoperative presence of tenosynovitis, as well as Soong grade and amount of soft-tissue coverage. This study negates our hypothesis that ultrasound is useful for identifying tendinopathy after distal radial anterior plate fixation.<b>Level of evidence:</b> II.</p>\",\"PeriodicalId\":94237,\"journal\":{\"name\":\"The Journal of hand surgery, European volume\",\"volume\":\" \",\"pages\":\"17531934241268971\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of hand surgery, European volume\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/17531934241268971\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of hand surgery, European volume","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17531934241268971","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

这项研究比较了超声波与临床和X光测量方法,以评估与桡骨远端前锁定钢板相关的肌腱病变。共有46名患者接受了桡骨远端钢板移除手术,他们在术前接受了临床检查、X光片和超声波评估,以检测肌腱受刺激的证据。钢板移除过程中对肌腱的大体变化进行了评估。共有 32 名患者出现临床异常。13例患者出现宋二氏位置。超声波检查显示,9 名患者患有腱鞘炎,4 名患者肌腱纤维化或增厚,1 例患者肌腱部分断裂。术中评估显示,28 名患者患有腱鞘炎,8 名患者肌腱纤维不连续。超声波检查结果并不能预测术中腱鞘炎和腱鞘纤维断裂的情况。研究发现,宋氏分级越高,尤其是 2 级,与术中出现的腱鞘炎以及宋氏分级和软组织覆盖量之间的关系越密切。这项研究否定了我们的假设,即超声波有助于识别桡骨远端前钢板固定术后的腱鞘炎:证据等级:II。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The use of ultrasound to predict flexor tendinopathy after anterior locking plating of the distal radius.

This study compares ultrasound to clinical and radiographic measurements for assessing tendon pathology associated with distal radial anterior locking plates. A total of 46 patients undergoing removal of a distal radial plate had a preoperative clinical examination, radiographs and ultrasound evaluation to detect evidence of tendon irritation. Gross changes to the tendon were assessed during plate removal. In total, 32 patients demonstrated clinical abnormality. Soong 2 position was noted in 13 patients. Ultrasound revealed tenosynovitis in nine patients, tendon fibrillation or thickening in four patients and a single case of partial discontinuity. Intraoperative assessment revealed tenosynovitis in 28 patients and tendon fibre discontinuity in eight patients. Ultrasound findings were not predictive of intraoperative tenosynovitis and discontinuity. A relationship was noted between higher Soong grade, especially grade 2, and intraoperative presence of tenosynovitis, as well as Soong grade and amount of soft-tissue coverage. This study negates our hypothesis that ultrasound is useful for identifying tendinopathy after distal radial anterior plate fixation.Level of evidence: II.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Bowstringing of the extensor digitorum: clinical and biomechanical results using an ankle extensor retinaculum graft. Repair of palmar soft tissue defects of five digits in the same hand using a variety of free flaps. Enhancing systematic review efficiency in hand surgery using artificial intelligence (natural language processing) for abstract screening. Highlights of hand surgery randomized controlled trials : Randomized controlled trial highlights. Intramedullary nailing for concomitant extra-articular ulnar head fractures in distal radial fractures.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1