检测非洲高血压患者 LVH 的心电图标准的性能。

IF 1.3 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of electrocardiology Pub Date : 2024-08-12 DOI:10.1016/j.jelectrocard.2024.153773
David Vandroux MD , Salmane Amidou MD, PhD , Souleymane Issa Sarki MD , Julien Magne MD, PhD , Yessito Corine Houehanou MD, PhD , Lucie Chastaingt MD , Victor Aboyans MD, PhD, FESC , Philippe Lacroix MD, PhD , on behalf of TAHES study investigators
{"title":"检测非洲高血压患者 LVH 的心电图标准的性能。","authors":"David Vandroux MD ,&nbsp;Salmane Amidou MD, PhD ,&nbsp;Souleymane Issa Sarki MD ,&nbsp;Julien Magne MD, PhD ,&nbsp;Yessito Corine Houehanou MD, PhD ,&nbsp;Lucie Chastaingt MD ,&nbsp;Victor Aboyans MD, PhD, FESC ,&nbsp;Philippe Lacroix MD, PhD ,&nbsp;on behalf of TAHES study investigators","doi":"10.1016/j.jelectrocard.2024.153773","DOIUrl":null,"url":null,"abstract":"<div><h3>Aims</h3><p>To evaluate the performance of the currently accepted LVH electrocardiographic (ECG) criteria from ethnic-specific normal values.</p></div><div><h3>Methods and results</h3><p>We included 309 hypertensive subjects with both ECG (12‑leads device) and echocardiographic analysis. The diagnosis of LVH was established by echocardiography from specific norms. Current ECG criteria for the diagnosis of LVH have low performances. Area Under Curve of Sokolow-Lyon, Peguero-Lo Presti, Cornell voltage and Cornell Product were respectively 0.61, 0.65, 0.72 and 0.71.</p></div><div><h3>Conclusion</h3><p>In hypertensive African, the most accurate criterion for diagnosing LVH is Cornell voltage.</p></div>","PeriodicalId":15606,"journal":{"name":"Journal of electrocardiology","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance of electrocardiographic criteria for detecting LVH in hypertensive Africans\",\"authors\":\"David Vandroux MD ,&nbsp;Salmane Amidou MD, PhD ,&nbsp;Souleymane Issa Sarki MD ,&nbsp;Julien Magne MD, PhD ,&nbsp;Yessito Corine Houehanou MD, PhD ,&nbsp;Lucie Chastaingt MD ,&nbsp;Victor Aboyans MD, PhD, FESC ,&nbsp;Philippe Lacroix MD, PhD ,&nbsp;on behalf of TAHES study investigators\",\"doi\":\"10.1016/j.jelectrocard.2024.153773\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Aims</h3><p>To evaluate the performance of the currently accepted LVH electrocardiographic (ECG) criteria from ethnic-specific normal values.</p></div><div><h3>Methods and results</h3><p>We included 309 hypertensive subjects with both ECG (12‑leads device) and echocardiographic analysis. The diagnosis of LVH was established by echocardiography from specific norms. Current ECG criteria for the diagnosis of LVH have low performances. Area Under Curve of Sokolow-Lyon, Peguero-Lo Presti, Cornell voltage and Cornell Product were respectively 0.61, 0.65, 0.72 and 0.71.</p></div><div><h3>Conclusion</h3><p>In hypertensive African, the most accurate criterion for diagnosing LVH is Cornell voltage.</p></div>\",\"PeriodicalId\":15606,\"journal\":{\"name\":\"Journal of electrocardiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of electrocardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0022073624002437\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of electrocardiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022073624002437","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

目的:从特定种族的正常值评估目前公认的 LVH 心电图(ECG)标准的性能:我们对 309 名高血压患者进行了心电图(12 导联装置)和超声心动图分析。左心室肥厚的诊断是通过超声心动图根据特定标准确定的。目前诊断 LVH 的心电图标准性能较低。Sokolow-Lyon、Peguero-Lo Presti、Cornell 电压和 Cornell Product 的曲线下面积分别为 0.61、0.65、0.72 和 0.71:在非洲高血压患者中,诊断 LVH 的最准确标准是康奈尔电压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance of electrocardiographic criteria for detecting LVH in hypertensive Africans

Aims

To evaluate the performance of the currently accepted LVH electrocardiographic (ECG) criteria from ethnic-specific normal values.

Methods and results

We included 309 hypertensive subjects with both ECG (12‑leads device) and echocardiographic analysis. The diagnosis of LVH was established by echocardiography from specific norms. Current ECG criteria for the diagnosis of LVH have low performances. Area Under Curve of Sokolow-Lyon, Peguero-Lo Presti, Cornell voltage and Cornell Product were respectively 0.61, 0.65, 0.72 and 0.71.

Conclusion

In hypertensive African, the most accurate criterion for diagnosing LVH is Cornell voltage.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of electrocardiology
Journal of electrocardiology 医学-心血管系统
CiteScore
2.70
自引率
7.70%
发文量
152
审稿时长
38 days
期刊介绍: The Journal of Electrocardiology is devoted exclusively to clinical and experimental studies of the electrical activities of the heart. It seeks to contribute significantly to the accuracy of diagnosis and prognosis and the effective treatment, prevention, or delay of heart disease. Editorial contents include electrocardiography, vectorcardiography, arrhythmias, membrane action potential, cardiac pacing, monitoring defibrillation, instrumentation, drug effects, and computer applications.
期刊最新文献
The de Winter electrocardiographic pattern: A systematic review of case reports. Nonparoxysmal junctional tachycardia associated with 3:2 Wenckebach exit block in the absence of digitalis therapy Study on the feasibility of distinguishing ventricular and pre-excited arrhythmia rhythms by a new algorithm The ECG of a 6-year-old girl Use of ST/HR hysteresis decreases false positive rate in exercise electrocardiography test of middle-aged asymptomatic women
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1