{"title":"具有胫骨卸载机制的髌腱承托支架的设计与评估","authors":"Vahid Chamani, Mahmood Bahramizahed, Mobina Khosravi, Akbar Biglarian, Gholamreza Ghorbani Amjad, Seyyed Mohammad Ebrahim Mousavi, Mokhtar Arazpour","doi":"10.31661/jbpe.v0i0.2403-1738","DOIUrl":null,"url":null,"abstract":"<p><p>The current study aimed to design a patellar-tendon-bearing (PTB) brace capable of measuring and quantifying weight offloading on the tibia. The PTB brace was designed with off-loading mechanism on the tibia with features, including ankle joint, vertical sliding adaptor, vertical sliding piece, and upper connector of load cells to PTB brace. Also, the present study investigated the effect of brace on 20 healthy individuals under 8 different off-loading conditions, based on measuring the vertical distance between the calf shells and foot plate through a sliding adapter at 0.5, 1, 1.5, 2, 2.5, 3, and 3.5 cm. The Pedar device and load cells embedded in PTB brace were used to determine the extent of offloading and assess the reliability and validity of brace. Increasing the vertical distance between the calf shells and the footplate can lead to a greater amount of offloading. Accordingly, off-loading ranged from a minimum of 16.5% at 0 cm position to a maximum of 60.48% at 3.5 cm position of sliding adapter. Percentage values of tibia off-loading in 8 conditions were not significantly different in Padar devices and PTB brace. Therefore, PTB brace load cells, as a valid method, can measure off-loading levels. When fabricating a PTB brace, a monitoring system with load cells is essential to measure the amount of tibial offloading, leading to readjustment if limb slides down inside the brace. Additionally, a component is needed to correctly position limb in off-loading condition. In the current study, sliding adapter of brace can provide that capability.</p>","PeriodicalId":38035,"journal":{"name":"Journal of Biomedical Physics and Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11336054/pdf/","citationCount":"0","resultStr":"{\"title\":\"Design and Evaluation of a Patellar Tendon-Bearing Brace with Off-Loading Mechanism on Tibia.\",\"authors\":\"Vahid Chamani, Mahmood Bahramizahed, Mobina Khosravi, Akbar Biglarian, Gholamreza Ghorbani Amjad, Seyyed Mohammad Ebrahim Mousavi, Mokhtar Arazpour\",\"doi\":\"10.31661/jbpe.v0i0.2403-1738\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The current study aimed to design a patellar-tendon-bearing (PTB) brace capable of measuring and quantifying weight offloading on the tibia. The PTB brace was designed with off-loading mechanism on the tibia with features, including ankle joint, vertical sliding adaptor, vertical sliding piece, and upper connector of load cells to PTB brace. Also, the present study investigated the effect of brace on 20 healthy individuals under 8 different off-loading conditions, based on measuring the vertical distance between the calf shells and foot plate through a sliding adapter at 0.5, 1, 1.5, 2, 2.5, 3, and 3.5 cm. The Pedar device and load cells embedded in PTB brace were used to determine the extent of offloading and assess the reliability and validity of brace. Increasing the vertical distance between the calf shells and the footplate can lead to a greater amount of offloading. Accordingly, off-loading ranged from a minimum of 16.5% at 0 cm position to a maximum of 60.48% at 3.5 cm position of sliding adapter. Percentage values of tibia off-loading in 8 conditions were not significantly different in Padar devices and PTB brace. Therefore, PTB brace load cells, as a valid method, can measure off-loading levels. When fabricating a PTB brace, a monitoring system with load cells is essential to measure the amount of tibial offloading, leading to readjustment if limb slides down inside the brace. Additionally, a component is needed to correctly position limb in off-loading condition. In the current study, sliding adapter of brace can provide that capability.</p>\",\"PeriodicalId\":38035,\"journal\":{\"name\":\"Journal of Biomedical Physics and Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11336054/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomedical Physics and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31661/jbpe.v0i0.2403-1738\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31661/jbpe.v0i0.2403-1738","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在设计一种能够测量和量化胫骨重量卸载的髌腱承(PTB)支架。PTB 支架的设计具有胫骨卸载机制,其特征包括踝关节、垂直滑动适配器、垂直滑动件以及与 PTB 支架相连的称重传感器上部连接器。此外,本研究还通过滑动适配器测量小腿外壳和脚板之间的垂直距离,分别为 0.5 厘米、1 厘米、1.5 厘米、2 厘米、2.5 厘米、3 厘米和 3.5 厘米,研究了 20 名健康人在 8 种不同卸载条件下使用支架的效果。使用 Pedar 装置和嵌入 PTB 支架的称重传感器来确定卸载程度,并评估支架的可靠性和有效性。增加小腿外壳与脚板之间的垂直距离可导致更大的卸载量。因此,在滑动适配器 0 厘米位置时,卸载率最低为 16.5%,而在滑动适配器 3.5 厘米位置时,卸载率最高为 60.48%。在 8 种情况下,Padar 装置和 PTB 支架的胫骨卸载百分比值没有明显差异。因此,PTB 支架称重传感器作为一种有效的方法,可以测量偏载水平。在制作 PTB 支架时,必须使用带传感器的监测系统来测量胫骨卸载量,以便在肢体在支架内下滑时进行重新调整。此外,还需要一个部件来正确定位处于卸载状态的肢体。在当前的研究中,支撑架的滑动适配器可以提供这种功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and Evaluation of a Patellar Tendon-Bearing Brace with Off-Loading Mechanism on Tibia.

The current study aimed to design a patellar-tendon-bearing (PTB) brace capable of measuring and quantifying weight offloading on the tibia. The PTB brace was designed with off-loading mechanism on the tibia with features, including ankle joint, vertical sliding adaptor, vertical sliding piece, and upper connector of load cells to PTB brace. Also, the present study investigated the effect of brace on 20 healthy individuals under 8 different off-loading conditions, based on measuring the vertical distance between the calf shells and foot plate through a sliding adapter at 0.5, 1, 1.5, 2, 2.5, 3, and 3.5 cm. The Pedar device and load cells embedded in PTB brace were used to determine the extent of offloading and assess the reliability and validity of brace. Increasing the vertical distance between the calf shells and the footplate can lead to a greater amount of offloading. Accordingly, off-loading ranged from a minimum of 16.5% at 0 cm position to a maximum of 60.48% at 3.5 cm position of sliding adapter. Percentage values of tibia off-loading in 8 conditions were not significantly different in Padar devices and PTB brace. Therefore, PTB brace load cells, as a valid method, can measure off-loading levels. When fabricating a PTB brace, a monitoring system with load cells is essential to measure the amount of tibial offloading, leading to readjustment if limb slides down inside the brace. Additionally, a component is needed to correctly position limb in off-loading condition. In the current study, sliding adapter of brace can provide that capability.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Biomedical Physics and Engineering
Journal of Biomedical Physics and Engineering Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
2.90
自引率
0.00%
发文量
64
审稿时长
10 weeks
期刊介绍: The Journal of Biomedical Physics and Engineering (JBPE) is a bimonthly peer-reviewed English-language journal that publishes high-quality basic sciences and clinical research (experimental or theoretical) broadly concerned with the relationship of physics to medicine and engineering.
期刊最新文献
A Neural Network-based Approach to Prediction of Preterm Birth using Non-invasive Tests. Altered Amplitude of Low-Frequency Fluctuations of rs-fMRI Signal followed by rTMS Analgesic Effects in Non-Specific Chronic Low Back Pain (CLBP) Patients. Comparative Evaluation of LED Light Application and Heat Generation with Three Different Wavelengths of Frequency on Soft Tissues in Bringing Faster Orthodontic Tooth Movement: A Finite Element Model Study. Feasibility of Robot-Assistance Hand Physiotherapy in Post-Stroke Patients. Impact of Electronic Collimation on Reducing Unnecessary Patient Dose in Digital Radiography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1