血清脑磷脂氧化酶活性:被忽视的威尔逊氏病诊断生物标志物

IF 3.1 3区 医学 Q2 CLINICAL NEUROLOGY Parkinsonism & related disorders Pub Date : 2024-08-17 DOI:10.1016/j.parkreldis.2024.107105
Yue Yang , Ting Cheng , Wenming Yang , Yu Wang , Yulong Yang , Hu Xi , Qianqian Zhu
{"title":"血清脑磷脂氧化酶活性:被忽视的威尔逊氏病诊断生物标志物","authors":"Yue Yang ,&nbsp;Ting Cheng ,&nbsp;Wenming Yang ,&nbsp;Yu Wang ,&nbsp;Yulong Yang ,&nbsp;Hu Xi ,&nbsp;Qianqian Zhu","doi":"10.1016/j.parkreldis.2024.107105","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Low serum ceruloplasmin concentration is considered robust marker for Wilson disease (WD) screening, measuring serum ceruloplasmin oxidase activity might be an even more valuable diagnostic tool, but it has not been sufficiently studied.</p></div><div><h3>Methods</h3><p>All patients who were assessed for serum ceruloplasmin oxidase activity between January 1, 2016, and September 2, 2019, were enrolled in this study. The diagnostic performance of serum ceruloplasmin oxidase activity was analyzed using receiver operating characteristic curve analysis (ROC), Spearman's rank correlation, and Mann-Whitney <em>U</em> test.</p></div><div><h3>Results</h3><p>Serum ceruloplasmin oxidase activity was significantly decreased in WD patients (0.87 U/L, IQR 0.61–1.54). The optimal cut-off of serum ceruloplasmin oxidase activity to identified WD is 7 U/L, with sensitivity and specificity of 97.03 % and 98.19 %, respectively. Furthermore, this study revealed a positive correlation between enzymatic and immunoreactive serum ceruloplasmin tests. As primary diagnostic methods, serum ceruloplasmin levels below the diagnostic cut-offs for either the enzymatic or immunoreactive tests were observed in 818 out of 842 WD patients (97.15 %). Compared with the presence of K-F rings in asymptomatic patients, the accuracy of serum ceruloplasmin tests was significantly higher (56.12 % VS 95.08 %). Moreover, the positive rate of cranial MRI in neurological patients was similar to the tests of serum ceruloplasmin (92.91 % VS 97.40 %). Moreover, 71 patients had ambiguous genetic results, complicating the diagnosis. However, serum ceruloplasmin tests successfully identified 65 out of these 71 patients (91.55 %).</p></div><div><h3>Conclusion</h3><p>Serum ceruloplasmin oxidase activity has excellent performance in diagnosing WD, which should be widely used as preferred test in WD patients.</p></div>","PeriodicalId":19970,"journal":{"name":"Parkinsonism & related disorders","volume":"127 ","pages":"Article 107105"},"PeriodicalIF":3.1000,"publicationDate":"2024-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1353802024011179/pdfft?md5=74e32bdcb66af3df926afe16d5de8856&pid=1-s2.0-S1353802024011179-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Serum ceruloplasmin oxidase activity: A neglected diagnostic biomarker for Wilson disease\",\"authors\":\"Yue Yang ,&nbsp;Ting Cheng ,&nbsp;Wenming Yang ,&nbsp;Yu Wang ,&nbsp;Yulong Yang ,&nbsp;Hu Xi ,&nbsp;Qianqian Zhu\",\"doi\":\"10.1016/j.parkreldis.2024.107105\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Low serum ceruloplasmin concentration is considered robust marker for Wilson disease (WD) screening, measuring serum ceruloplasmin oxidase activity might be an even more valuable diagnostic tool, but it has not been sufficiently studied.</p></div><div><h3>Methods</h3><p>All patients who were assessed for serum ceruloplasmin oxidase activity between January 1, 2016, and September 2, 2019, were enrolled in this study. The diagnostic performance of serum ceruloplasmin oxidase activity was analyzed using receiver operating characteristic curve analysis (ROC), Spearman's rank correlation, and Mann-Whitney <em>U</em> test.</p></div><div><h3>Results</h3><p>Serum ceruloplasmin oxidase activity was significantly decreased in WD patients (0.87 U/L, IQR 0.61–1.54). The optimal cut-off of serum ceruloplasmin oxidase activity to identified WD is 7 U/L, with sensitivity and specificity of 97.03 % and 98.19 %, respectively. Furthermore, this study revealed a positive correlation between enzymatic and immunoreactive serum ceruloplasmin tests. As primary diagnostic methods, serum ceruloplasmin levels below the diagnostic cut-offs for either the enzymatic or immunoreactive tests were observed in 818 out of 842 WD patients (97.15 %). Compared with the presence of K-F rings in asymptomatic patients, the accuracy of serum ceruloplasmin tests was significantly higher (56.12 % VS 95.08 %). Moreover, the positive rate of cranial MRI in neurological patients was similar to the tests of serum ceruloplasmin (92.91 % VS 97.40 %). Moreover, 71 patients had ambiguous genetic results, complicating the diagnosis. However, serum ceruloplasmin tests successfully identified 65 out of these 71 patients (91.55 %).</p></div><div><h3>Conclusion</h3><p>Serum ceruloplasmin oxidase activity has excellent performance in diagnosing WD, which should be widely used as preferred test in WD patients.</p></div>\",\"PeriodicalId\":19970,\"journal\":{\"name\":\"Parkinsonism & related disorders\",\"volume\":\"127 \",\"pages\":\"Article 107105\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-08-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1353802024011179/pdfft?md5=74e32bdcb66af3df926afe16d5de8856&pid=1-s2.0-S1353802024011179-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Parkinsonism & related disorders\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1353802024011179\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Parkinsonism & related disorders","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1353802024011179","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景低血清脑磷脂浓度被认为是威尔逊病(WD)筛查的可靠标志物,测量血清脑磷脂氧化酶活性可能是一种更有价值的诊断工具,但尚未得到充分研究。方法本研究纳入了2016年1月1日至2019年9月2日期间接受血清脑磷脂氧化酶活性评估的所有患者。结果WD患者血清脑磷脂氧化酶活性显著降低(0.87 U/L,IQR 0.61-1.54)。确定 WD 的血清脑磷脂氧化酶活性的最佳临界值为 7 U/L,敏感性和特异性分别为 97.03 % 和 98.19 %。此外,该研究还发现酶法和免疫反应性血清脑磷脂检测之间存在正相关。作为主要诊断方法,在 842 例 WD 患者中,有 818 例(97.15%)的血清脑磷脂水平低于酶法或免疫反应法的诊断临界值。与无症状患者出现 K-F 环相比,血清脑磷脂检测的准确率明显更高(56.12% VS 95.08%)。此外,神经系统患者头颅磁共振成像的阳性率与血清脑磷脂的检测结果相似(92.91 % VS 97.40 %)。此外,71 名患者的基因检测结果不明确,使诊断变得复杂。结论血清脑磷脂氧化酶活性在诊断 WD 方面表现出色,应作为 WD 患者的首选检测方法广泛使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Serum ceruloplasmin oxidase activity: A neglected diagnostic biomarker for Wilson disease

Background

Low serum ceruloplasmin concentration is considered robust marker for Wilson disease (WD) screening, measuring serum ceruloplasmin oxidase activity might be an even more valuable diagnostic tool, but it has not been sufficiently studied.

Methods

All patients who were assessed for serum ceruloplasmin oxidase activity between January 1, 2016, and September 2, 2019, were enrolled in this study. The diagnostic performance of serum ceruloplasmin oxidase activity was analyzed using receiver operating characteristic curve analysis (ROC), Spearman's rank correlation, and Mann-Whitney U test.

Results

Serum ceruloplasmin oxidase activity was significantly decreased in WD patients (0.87 U/L, IQR 0.61–1.54). The optimal cut-off of serum ceruloplasmin oxidase activity to identified WD is 7 U/L, with sensitivity and specificity of 97.03 % and 98.19 %, respectively. Furthermore, this study revealed a positive correlation between enzymatic and immunoreactive serum ceruloplasmin tests. As primary diagnostic methods, serum ceruloplasmin levels below the diagnostic cut-offs for either the enzymatic or immunoreactive tests were observed in 818 out of 842 WD patients (97.15 %). Compared with the presence of K-F rings in asymptomatic patients, the accuracy of serum ceruloplasmin tests was significantly higher (56.12 % VS 95.08 %). Moreover, the positive rate of cranial MRI in neurological patients was similar to the tests of serum ceruloplasmin (92.91 % VS 97.40 %). Moreover, 71 patients had ambiguous genetic results, complicating the diagnosis. However, serum ceruloplasmin tests successfully identified 65 out of these 71 patients (91.55 %).

Conclusion

Serum ceruloplasmin oxidase activity has excellent performance in diagnosing WD, which should be widely used as preferred test in WD patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Parkinsonism & related disorders
Parkinsonism & related disorders 医学-临床神经学
CiteScore
6.20
自引率
4.90%
发文量
292
审稿时长
39 days
期刊介绍: Parkinsonism & Related Disorders publishes the results of basic and clinical research contributing to the understanding, diagnosis and treatment of all neurodegenerative syndromes in which Parkinsonism, Essential Tremor or related movement disorders may be a feature. Regular features will include: Review Articles, Point of View articles, Full-length Articles, Short Communications, Case Reports and Letter to the Editor.
期刊最新文献
A multidisciplinary telemedicine approach for managing frailty in Parkinson's disease. A longitudinal, case-control study Gerstmann-Straussler-Scheinker disease: Lessons from two new Indian kindreds Exposure factors and clinical characteristics associated with Parkinson's disease in GBA1 variant carriers: A Chinese GBA1-PD intrafamilial survey Unsupervised definition of two clinical subtypes of Essential tremor and the underlying brain topology Context-dependency of the REM sleep behavior disorder screening questionnaire - Clinical utility under scrutiny
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1