现代植发手术并发症范围综述:不仅仅是分叉。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-08-23 DOI:10.1007/s00266-024-04316-3
Rui Han Liu, Lucy J Xu, Justin C McCarty, Roy Xiao, Jenny X Chen, Linda N Lee
{"title":"现代植发手术并发症范围综述:不仅仅是分叉。","authors":"Rui Han Liu, Lucy J Xu, Justin C McCarty, Roy Xiao, Jenny X Chen, Linda N Lee","doi":"10.1007/s00266-024-04316-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Hair restoration surgery (HRS) is a commonly performed elective procedure but to date lacks a review of the full scope of complications.</p><p><strong>Objectives: </strong>To provide a comprehensive overview of observed complications associated with follicular unit extraction (FUE) and follicular unit transplantation (FUT).</p><p><strong>Eligibility criteria: </strong>Randomized control trials, cohort studies, case series, and case reports published in 1985 or later on adults (age>18). Nontraumatic or autoimmune etiologies of alopecia were excluded as procedure indications.</p><p><strong>Sources of evidence: </strong>PubMed, EMBASE, Cochrane databases (last search December 31, 2022).</p><p><strong>Charting methods: </strong>Data-charting and extraction were independently performed with two reviewers using Covidence.</p><p><strong>Results: </strong>Forty-three publications were included. Two large series reported the overall complication rate to be 1.2 and 4.7%. Common complications included bleeding requiring intervention (up to 8%), persistent numbness (up to 11%), infection (up to 11% with two reports of Kaposi varicelliform eruptions and one of mucormycosis), effluvium at donor and recipient sites (up to 4.1% and 6.5%, respectively). The most common donor-site complication was hypertrophic scarring/keloid formation after FUT (up to 15.1%). Complications at the recipient site, including crusting (up to 54.8%), frontal edema (up to 50%), and sterile folliculitis (up to 53.3%), tended to be poorly defined with a broad range of incidences.</p><p><strong>Conclusion: </strong>Serious complications associated with HRS are rare in the hands of experienced providers. However, comprehensive discussions of risk must be had with prospective patients as any complication in the context of an elective procedure may be significant and psychologically devastating for the individual patient.</p><p><strong>Level of evidence v: </strong>This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Scoping Review on Complications in Modern Hair Transplantation: More than Just Splitting Hairs.\",\"authors\":\"Rui Han Liu, Lucy J Xu, Justin C McCarty, Roy Xiao, Jenny X Chen, Linda N Lee\",\"doi\":\"10.1007/s00266-024-04316-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Hair restoration surgery (HRS) is a commonly performed elective procedure but to date lacks a review of the full scope of complications.</p><p><strong>Objectives: </strong>To provide a comprehensive overview of observed complications associated with follicular unit extraction (FUE) and follicular unit transplantation (FUT).</p><p><strong>Eligibility criteria: </strong>Randomized control trials, cohort studies, case series, and case reports published in 1985 or later on adults (age>18). Nontraumatic or autoimmune etiologies of alopecia were excluded as procedure indications.</p><p><strong>Sources of evidence: </strong>PubMed, EMBASE, Cochrane databases (last search December 31, 2022).</p><p><strong>Charting methods: </strong>Data-charting and extraction were independently performed with two reviewers using Covidence.</p><p><strong>Results: </strong>Forty-three publications were included. Two large series reported the overall complication rate to be 1.2 and 4.7%. Common complications included bleeding requiring intervention (up to 8%), persistent numbness (up to 11%), infection (up to 11% with two reports of Kaposi varicelliform eruptions and one of mucormycosis), effluvium at donor and recipient sites (up to 4.1% and 6.5%, respectively). The most common donor-site complication was hypertrophic scarring/keloid formation after FUT (up to 15.1%). Complications at the recipient site, including crusting (up to 54.8%), frontal edema (up to 50%), and sterile folliculitis (up to 53.3%), tended to be poorly defined with a broad range of incidences.</p><p><strong>Conclusion: </strong>Serious complications associated with HRS are rare in the hands of experienced providers. However, comprehensive discussions of risk must be had with prospective patients as any complication in the context of an elective procedure may be significant and psychologically devastating for the individual patient.</p><p><strong>Level of evidence v: </strong>This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-08-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00266-024-04316-3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00266-024-04316-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

背景:头发修复手术(HRS)是一种常见的选择性手术,但迄今为止缺乏对全部并发症范围的审查:全面概述观察到的与毛囊单位提取术(FUE)和毛囊单位移植术(FUT)相关的并发症:随机对照试验、队列研究、病例系列和病例报告,这些研究发表于 1985 年或之后,对象为成年人(年龄大于 18 岁)。非创伤性或自身免疫性脱发病因不作为手术适应症:PubMed、EMBASE、Cochrane 数据库(最后一次搜索时间为 2022 年 12 月 31 日):数据制图和提取由两名审稿人使用 Covidence 独立完成:结果:共纳入 43 篇文献。两个大型系列报告的总体并发症发生率分别为1.2%和4.7%。常见的并发症包括需要介入治疗的出血(高达8%)、持续麻木(高达11%)、感染(高达11%,其中两篇报告了卡波西静脉曲张糜烂,一篇报告了粘液瘤病)、供体和受体部位的流脓(分别高达4.1%和6.5%)。最常见的供体部位并发症是 FUT 后增生性瘢痕/瘢痕疙瘩的形成(高达 15.1%)。受体部位的并发症包括结痂(高达54.8%)、额部水肿(高达50%)和无菌性毛囊炎(高达53.3%),这些并发症往往定义不清,发病率范围很广:结论:在经验丰富的医疗人员手中,与 HRS 相关的严重并发症很少发生。然而,必须与潜在患者就风险进行全面讨论,因为在选择性手术中出现的任何并发症都可能对患者造成重大影响和心理创伤:本期刊要求作者为每篇文章指定一个证据等级。有关这些循证医学等级的完整描述,请参阅目录或在线作者须知 www.springer.com/00266 。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Scoping Review on Complications in Modern Hair Transplantation: More than Just Splitting Hairs.

Background: Hair restoration surgery (HRS) is a commonly performed elective procedure but to date lacks a review of the full scope of complications.

Objectives: To provide a comprehensive overview of observed complications associated with follicular unit extraction (FUE) and follicular unit transplantation (FUT).

Eligibility criteria: Randomized control trials, cohort studies, case series, and case reports published in 1985 or later on adults (age>18). Nontraumatic or autoimmune etiologies of alopecia were excluded as procedure indications.

Sources of evidence: PubMed, EMBASE, Cochrane databases (last search December 31, 2022).

Charting methods: Data-charting and extraction were independently performed with two reviewers using Covidence.

Results: Forty-three publications were included. Two large series reported the overall complication rate to be 1.2 and 4.7%. Common complications included bleeding requiring intervention (up to 8%), persistent numbness (up to 11%), infection (up to 11% with two reports of Kaposi varicelliform eruptions and one of mucormycosis), effluvium at donor and recipient sites (up to 4.1% and 6.5%, respectively). The most common donor-site complication was hypertrophic scarring/keloid formation after FUT (up to 15.1%). Complications at the recipient site, including crusting (up to 54.8%), frontal edema (up to 50%), and sterile folliculitis (up to 53.3%), tended to be poorly defined with a broad range of incidences.

Conclusion: Serious complications associated with HRS are rare in the hands of experienced providers. However, comprehensive discussions of risk must be had with prospective patients as any complication in the context of an elective procedure may be significant and psychologically devastating for the individual patient.

Level of evidence v: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1