肺炎筛查中的呼出挥发性有机化合物检测:综合 Meta 分析。

IF 4.6 2区 医学 Q1 RESPIRATORY SYSTEM Lung Pub Date : 2024-08-24 DOI:10.1007/s00408-024-00737-8
Juan He, Ran Zhong, Linlu Xue, Yixuan Wang, Yang Chen, Zihui Xiong, Ziya Yang, Sitong Chen, Wenhua Liang, Jianxing He
{"title":"肺炎筛查中的呼出挥发性有机化合物检测:综合 Meta 分析。","authors":"Juan He, Ran Zhong, Linlu Xue, Yixuan Wang, Yang Chen, Zihui Xiong, Ziya Yang, Sitong Chen, Wenhua Liang, Jianxing He","doi":"10.1007/s00408-024-00737-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pneumonia is a common lower respiratory tract infection, and early diagnosis is crucial for timely treatment and improved prognosis. Traditional diagnostic methods for pneumonia, such as chest imaging and microbiological examinations, have certain limitations. Exhaled volatile organic compounds (VOCs) detection, as an emerging non-invasive diagnostic technique, has shown potential application value in pneumonia screening.</p><p><strong>Method: </strong>A systematic search was conducted on PubMed, Embase, Cochrane Library, and Web of Science, with the retrieval time up to March 2024. The inclusion criteria were diagnostic studies evaluating exhaled VOCs detection for the diagnosis of pneumonia, regardless of the trial design type. A meta-analysis was performed using a bivariate model for sensitivity and specificity.</p><p><strong>Results: </strong>A total of 14 diagnostic studies were included in this meta-analysis. The pooled results demonstrated that exhaled VOCs detection had a combined sensitivity of 0.94 (95% CI: 0.92-0.95) and a combined specificity of 0.83 (95% CI: 0.81-0.84) in pneumonia screening, with an area under the summary receiver operating characteristic (SROC) curve (AUC) of 0.96. The pooled diagnostic odds ratio (DOR) was 104.37 (95% CI: 27.93-390.03), and the pooled positive and negative likelihood ratios (LR) were 8.98 (95% CI: 3.88-20.80) and 0.11 (95% CI: 0.05-0.22), indicating a high diagnostic performance.</p><p><strong>Conclusion: </strong>This study highlights the potential of exhaled VOCs detection as an effective, non-invasive screening method for pneumonia, which could facilitate future diagnosis in pneumonia. Further high-quality, large-scale studies are required to confirm the clinical utility of exhaled VOCs detection in pneumonia screening.</p><p><strong>Study registration: </strong>PROSPERO, Review no. CRD42024520498.</p>","PeriodicalId":18163,"journal":{"name":"Lung","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Exhaled Volatile Organic Compounds Detection in Pneumonia Screening: A Comprehensive Meta-analysis.\",\"authors\":\"Juan He, Ran Zhong, Linlu Xue, Yixuan Wang, Yang Chen, Zihui Xiong, Ziya Yang, Sitong Chen, Wenhua Liang, Jianxing He\",\"doi\":\"10.1007/s00408-024-00737-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Pneumonia is a common lower respiratory tract infection, and early diagnosis is crucial for timely treatment and improved prognosis. Traditional diagnostic methods for pneumonia, such as chest imaging and microbiological examinations, have certain limitations. Exhaled volatile organic compounds (VOCs) detection, as an emerging non-invasive diagnostic technique, has shown potential application value in pneumonia screening.</p><p><strong>Method: </strong>A systematic search was conducted on PubMed, Embase, Cochrane Library, and Web of Science, with the retrieval time up to March 2024. The inclusion criteria were diagnostic studies evaluating exhaled VOCs detection for the diagnosis of pneumonia, regardless of the trial design type. A meta-analysis was performed using a bivariate model for sensitivity and specificity.</p><p><strong>Results: </strong>A total of 14 diagnostic studies were included in this meta-analysis. The pooled results demonstrated that exhaled VOCs detection had a combined sensitivity of 0.94 (95% CI: 0.92-0.95) and a combined specificity of 0.83 (95% CI: 0.81-0.84) in pneumonia screening, with an area under the summary receiver operating characteristic (SROC) curve (AUC) of 0.96. The pooled diagnostic odds ratio (DOR) was 104.37 (95% CI: 27.93-390.03), and the pooled positive and negative likelihood ratios (LR) were 8.98 (95% CI: 3.88-20.80) and 0.11 (95% CI: 0.05-0.22), indicating a high diagnostic performance.</p><p><strong>Conclusion: </strong>This study highlights the potential of exhaled VOCs detection as an effective, non-invasive screening method for pneumonia, which could facilitate future diagnosis in pneumonia. Further high-quality, large-scale studies are required to confirm the clinical utility of exhaled VOCs detection in pneumonia screening.</p><p><strong>Study registration: </strong>PROSPERO, Review no. CRD42024520498.</p>\",\"PeriodicalId\":18163,\"journal\":{\"name\":\"Lung\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-08-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lung\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00408-024-00737-8\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lung","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00408-024-00737-8","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

摘要

背景:肺炎是一种常见的下呼吸道感染,早期诊断对于及时治疗和改善预后至关重要。传统的肺炎诊断方法,如胸部影像学检查和微生物学检查,都有一定的局限性。呼出的挥发性有机化合物(VOCs)检测作为一种新兴的无创诊断技术,在肺炎筛查中显示出潜在的应用价值:在 PubMed、Embase、Cochrane Library 和 Web of Science 上进行了系统检索,检索时间截至 2024 年 3 月。纳入标准是评估呼出挥发性有机化合物检测对肺炎诊断的诊断性研究,无论试验设计类型如何。采用双变量模型对敏感性和特异性进行了荟萃分析:本次荟萃分析共纳入了 14 项诊断研究。汇总结果显示,在肺炎筛查中,呼出 VOCs 检测的综合灵敏度为 0.94(95% CI:0.92-0.95),综合特异度为 0.83(95% CI:0.81-0.84),汇总接收者操作特征曲线下面积(AUC)为 0.96。汇总诊断几率比(DOR)为 104.37(95% CI:27.93-390.03),汇总阳性和阴性似然比(LR)分别为 8.98(95% CI:3.88-20.80)和 0.11(95% CI:0.05-0.22),显示出较高的诊断性能:本研究强调了呼出挥发性有机化合物检测作为一种有效、无创的肺炎筛查方法的潜力,这将有助于未来的肺炎诊断。研究注册:研究注册:PROSPERO,审查号:CRD42024520498。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Exhaled Volatile Organic Compounds Detection in Pneumonia Screening: A Comprehensive Meta-analysis.

Background: Pneumonia is a common lower respiratory tract infection, and early diagnosis is crucial for timely treatment and improved prognosis. Traditional diagnostic methods for pneumonia, such as chest imaging and microbiological examinations, have certain limitations. Exhaled volatile organic compounds (VOCs) detection, as an emerging non-invasive diagnostic technique, has shown potential application value in pneumonia screening.

Method: A systematic search was conducted on PubMed, Embase, Cochrane Library, and Web of Science, with the retrieval time up to March 2024. The inclusion criteria were diagnostic studies evaluating exhaled VOCs detection for the diagnosis of pneumonia, regardless of the trial design type. A meta-analysis was performed using a bivariate model for sensitivity and specificity.

Results: A total of 14 diagnostic studies were included in this meta-analysis. The pooled results demonstrated that exhaled VOCs detection had a combined sensitivity of 0.94 (95% CI: 0.92-0.95) and a combined specificity of 0.83 (95% CI: 0.81-0.84) in pneumonia screening, with an area under the summary receiver operating characteristic (SROC) curve (AUC) of 0.96. The pooled diagnostic odds ratio (DOR) was 104.37 (95% CI: 27.93-390.03), and the pooled positive and negative likelihood ratios (LR) were 8.98 (95% CI: 3.88-20.80) and 0.11 (95% CI: 0.05-0.22), indicating a high diagnostic performance.

Conclusion: This study highlights the potential of exhaled VOCs detection as an effective, non-invasive screening method for pneumonia, which could facilitate future diagnosis in pneumonia. Further high-quality, large-scale studies are required to confirm the clinical utility of exhaled VOCs detection in pneumonia screening.

Study registration: PROSPERO, Review no. CRD42024520498.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Lung
Lung 医学-呼吸系统
CiteScore
9.10
自引率
10.00%
发文量
95
审稿时长
6-12 weeks
期刊介绍: Lung publishes original articles, reviews and editorials on all aspects of the healthy and diseased lungs, of the airways, and of breathing. Epidemiological, clinical, pathophysiological, biochemical, and pharmacological studies fall within the scope of the journal. Case reports, short communications and technical notes can be accepted if they are of particular interest.
期刊最新文献
The Effects of Diabetes on Gas Transfer Capacity, Lung Volumes, Muscle Strength, and Cardio-pulmonary Responses During Exercise Novel Therapeutic Target for ALI/ARDS: Forkhead Box Transcription Factors Utility of the 52-Gene Risk Score to Identify Patients with Idiopathic Pulmonary Fibrosis at Greater Risk of Mortality in the Era of Antifibrotic Therapy. Increased Pneumonia Risk Associated with Concomitant Use of Inhaled Corticosteroids and Benzodiazepines: A Pharmacovigilance Analysis. Exhaled Volatile Organic Compounds Detection in Pneumonia Screening: A Comprehensive Meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1