针头不锈钢中钴含量的比较。

Laura Berardi
{"title":"针头不锈钢中钴含量的比较。","authors":"Laura Berardi","doi":"10.5731/pdajpst.2024.012977","DOIUrl":null,"url":null,"abstract":"<p><p>Cobalt (Co) alloys are used extensively in a wide range of medical devices due to their biocompatibility, durability, and properties. In 2017 the European Chemical Agency (ECHA) proposed to classify Co metal as a category 1B carcinogen (i.e. presumed to have carcinogenic potential for humans), as a reproductive hazard category 1B (i.e. presumed human reproductive toxicant) and as a category 2 mutagen. Even more, the European Medical Device Regulation (MDR) requires that medical devices contain > 0,1 w/w of substances that are category 1 A and 1B (CMR). As far as the European Medical Device Regulation, it is not specified if the Co content and concentration had to be determined/measured on the entire product or only on the product components. The object of this work is the comparison of Co profile in three different suppliers of stainless-steel needles as is and after being processed (i.e. sterilized) and then provide the proper interpretation and application of MDR requirements. The study and the extractable profile demonstrate the low cobalt content on needles and on a total syringe, thus suggesting to consider the Co content only on the syringe component.</p>","PeriodicalId":19986,"journal":{"name":"PDA Journal of Pharmaceutical Science and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of the Cobalt Content in Needles Stainless Steel.\",\"authors\":\"Laura Berardi\",\"doi\":\"10.5731/pdajpst.2024.012977\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Cobalt (Co) alloys are used extensively in a wide range of medical devices due to their biocompatibility, durability, and properties. In 2017 the European Chemical Agency (ECHA) proposed to classify Co metal as a category 1B carcinogen (i.e. presumed to have carcinogenic potential for humans), as a reproductive hazard category 1B (i.e. presumed human reproductive toxicant) and as a category 2 mutagen. Even more, the European Medical Device Regulation (MDR) requires that medical devices contain > 0,1 w/w of substances that are category 1 A and 1B (CMR). As far as the European Medical Device Regulation, it is not specified if the Co content and concentration had to be determined/measured on the entire product or only on the product components. The object of this work is the comparison of Co profile in three different suppliers of stainless-steel needles as is and after being processed (i.e. sterilized) and then provide the proper interpretation and application of MDR requirements. The study and the extractable profile demonstrate the low cobalt content on needles and on a total syringe, thus suggesting to consider the Co content only on the syringe component.</p>\",\"PeriodicalId\":19986,\"journal\":{\"name\":\"PDA Journal of Pharmaceutical Science and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PDA Journal of Pharmaceutical Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5731/pdajpst.2024.012977\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PDA Journal of Pharmaceutical Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5731/pdajpst.2024.012977","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

钴(Co)合金因其生物相容性、耐久性和特性,被广泛应用于各种医疗器械中。2017 年,欧洲化学品管理局(ECHA)提议将钴金属列为 1B 类致癌物(即推定对人类具有致癌潜力)、1B 类生殖危害物(即推定对人类具有生殖毒性)和 2 类致突变物。此外,《欧洲医疗器械法规》(MDR)还要求医疗器械必须含有大于 0.1 w/w 的第 1 A 类和第 1B 类(CMR)物质。就欧洲医疗器械法规而言,没有明确规定 Co 的含量和浓度是必须针对整个产品还是仅针对产品组件进行测定/测量。这项工作的目的是比较三家不同供应商的不锈钢针头在原样和加工(即灭菌)后的钴含量,然后对 MDR 要求进行适当的解释和应用。这项研究和可萃取曲线表明,针头和整个注射器中的钴含量都很低,因此建议只考虑注射器部件中的钴含量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of the Cobalt Content in Needles Stainless Steel.

Cobalt (Co) alloys are used extensively in a wide range of medical devices due to their biocompatibility, durability, and properties. In 2017 the European Chemical Agency (ECHA) proposed to classify Co metal as a category 1B carcinogen (i.e. presumed to have carcinogenic potential for humans), as a reproductive hazard category 1B (i.e. presumed human reproductive toxicant) and as a category 2 mutagen. Even more, the European Medical Device Regulation (MDR) requires that medical devices contain > 0,1 w/w of substances that are category 1 A and 1B (CMR). As far as the European Medical Device Regulation, it is not specified if the Co content and concentration had to be determined/measured on the entire product or only on the product components. The object of this work is the comparison of Co profile in three different suppliers of stainless-steel needles as is and after being processed (i.e. sterilized) and then provide the proper interpretation and application of MDR requirements. The study and the extractable profile demonstrate the low cobalt content on needles and on a total syringe, thus suggesting to consider the Co content only on the syringe component.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
34
期刊最新文献
A Commentary on 'Understanding the non-equivalency of bio-fluorescent particle counts versus the colony forming unit'. Identification and Root Cause Analysis of the Visible Particles Commonly Encountered in the Biopharmaceutical Industry. A Strategic Guide to Improve and De-Risk Vaccine Development: CEPI's CMC Framework. A Review of Artificial Intelligence and Machine Learning in Product Life Cycle Management. Impact of Dimensional Variability of Primary Packaging Materials on the Break-Loose and Gliding Forces of Prefilled Syringes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1