Michaela Domsicova , Simona Kurekova , Andrea Babelova , Kristina Jakic , Iveta Oravcova , Veronika Nemethova , Filip Razga , Albert Breier , Miroslav Gal , Alexandra Poturnayova
{"title":"慢性髓性白血病检测的进展:开发和评估用于临床实践的新型 QCM 合传感器","authors":"Michaela Domsicova , Simona Kurekova , Andrea Babelova , Kristina Jakic , Iveta Oravcova , Veronika Nemethova , Filip Razga , Albert Breier , Miroslav Gal , Alexandra Poturnayova","doi":"10.1016/j.bbrep.2024.101816","DOIUrl":null,"url":null,"abstract":"<div><p>Oncological diseases represent a significant global health challenge, with high mortality rates. Early detection is crucial for effective treatment, and aptamers, which demonstrate superior specificity and stability compared to antibodies, offer a promising avenue for diagnostic advancement. This study presents the design, development and evaluation of a quartz crystal microbalance (QCM) sensor functionalized with the T2-KK1B10 aptamer for the sensitive and specific detection of Chronic Myeloid Leukemia (CML) K562 cells. The research focuses on optimizing the biorecognition layer by adjusting the aptamer conditions, demonstrating the sensor's ability to detect these CML cells with high specificity and sensitivity. The aptamer-modified QCM sensor operates on the principle of mass change detection upon binding of target cells. By employing the Langmuir isotherm model, the performance of the sensor was optimized for the capture of CML cells from biological samples with LOD of 263 K562 cells. The sensor was also successfully regenerated multiple times without sensitivity loss. Validation of the sensor's performance was conducted under controlled laboratory settings, followed by extensive testing utilizing human lyophilized plasma and clinical samples from patients. The sensor exhibited high sensitivity and specificity in the detection of CML cells within clinical specimens, thereby illustrating its potential for practical clinical deployment. This research presents a novel approach to the early diagnosis of CML, facilitating timely intervention and enhanced patient outcomes. The developed aptasensor demonstrates potential for broader application in cancer diagnostics and personalized medicine.</p></div>","PeriodicalId":8771,"journal":{"name":"Biochemistry and Biophysics Reports","volume":"39 ","pages":"Article 101816"},"PeriodicalIF":2.3000,"publicationDate":"2024-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2405580824001808/pdfft?md5=7e8c7499d0d542bd7074971f3c6d3dbe&pid=1-s2.0-S2405580824001808-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Advancements in Chronic Myeloid Leukemia detection: Development and evaluation of a novel QCM aptasensor for use in clinical practice\",\"authors\":\"Michaela Domsicova , Simona Kurekova , Andrea Babelova , Kristina Jakic , Iveta Oravcova , Veronika Nemethova , Filip Razga , Albert Breier , Miroslav Gal , Alexandra Poturnayova\",\"doi\":\"10.1016/j.bbrep.2024.101816\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Oncological diseases represent a significant global health challenge, with high mortality rates. Early detection is crucial for effective treatment, and aptamers, which demonstrate superior specificity and stability compared to antibodies, offer a promising avenue for diagnostic advancement. This study presents the design, development and evaluation of a quartz crystal microbalance (QCM) sensor functionalized with the T2-KK1B10 aptamer for the sensitive and specific detection of Chronic Myeloid Leukemia (CML) K562 cells. The research focuses on optimizing the biorecognition layer by adjusting the aptamer conditions, demonstrating the sensor's ability to detect these CML cells with high specificity and sensitivity. The aptamer-modified QCM sensor operates on the principle of mass change detection upon binding of target cells. By employing the Langmuir isotherm model, the performance of the sensor was optimized for the capture of CML cells from biological samples with LOD of 263 K562 cells. The sensor was also successfully regenerated multiple times without sensitivity loss. Validation of the sensor's performance was conducted under controlled laboratory settings, followed by extensive testing utilizing human lyophilized plasma and clinical samples from patients. The sensor exhibited high sensitivity and specificity in the detection of CML cells within clinical specimens, thereby illustrating its potential for practical clinical deployment. This research presents a novel approach to the early diagnosis of CML, facilitating timely intervention and enhanced patient outcomes. The developed aptasensor demonstrates potential for broader application in cancer diagnostics and personalized medicine.</p></div>\",\"PeriodicalId\":8771,\"journal\":{\"name\":\"Biochemistry and Biophysics Reports\",\"volume\":\"39 \",\"pages\":\"Article 101816\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-08-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2405580824001808/pdfft?md5=7e8c7499d0d542bd7074971f3c6d3dbe&pid=1-s2.0-S2405580824001808-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biochemistry and Biophysics Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2405580824001808\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biochemistry and Biophysics Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2405580824001808","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
Advancements in Chronic Myeloid Leukemia detection: Development and evaluation of a novel QCM aptasensor for use in clinical practice
Oncological diseases represent a significant global health challenge, with high mortality rates. Early detection is crucial for effective treatment, and aptamers, which demonstrate superior specificity and stability compared to antibodies, offer a promising avenue for diagnostic advancement. This study presents the design, development and evaluation of a quartz crystal microbalance (QCM) sensor functionalized with the T2-KK1B10 aptamer for the sensitive and specific detection of Chronic Myeloid Leukemia (CML) K562 cells. The research focuses on optimizing the biorecognition layer by adjusting the aptamer conditions, demonstrating the sensor's ability to detect these CML cells with high specificity and sensitivity. The aptamer-modified QCM sensor operates on the principle of mass change detection upon binding of target cells. By employing the Langmuir isotherm model, the performance of the sensor was optimized for the capture of CML cells from biological samples with LOD of 263 K562 cells. The sensor was also successfully regenerated multiple times without sensitivity loss. Validation of the sensor's performance was conducted under controlled laboratory settings, followed by extensive testing utilizing human lyophilized plasma and clinical samples from patients. The sensor exhibited high sensitivity and specificity in the detection of CML cells within clinical specimens, thereby illustrating its potential for practical clinical deployment. This research presents a novel approach to the early diagnosis of CML, facilitating timely intervention and enhanced patient outcomes. The developed aptasensor demonstrates potential for broader application in cancer diagnostics and personalized medicine.
期刊介绍:
Open access, online only, peer-reviewed international journal in the Life Sciences, established in 2014 Biochemistry and Biophysics Reports (BB Reports) publishes original research in all aspects of Biochemistry, Biophysics and related areas like Molecular and Cell Biology. BB Reports welcomes solid though more preliminary, descriptive and small scale results if they have the potential to stimulate and/or contribute to future research, leading to new insights or hypothesis. Primary criteria for acceptance is that the work is original, scientifically and technically sound and provides valuable knowledge to life sciences research. We strongly believe all results deserve to be published and documented for the advancement of science. BB Reports specifically appreciates receiving reports on: Negative results, Replication studies, Reanalysis of previous datasets.