利用质谱法快速鉴定 SARS CoV-2 omicron 亚变体 JN.1 (BA.2.86.1.1)

IF 3.1 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY Journal of Mass Spectrometry and Advances in the Clinical Lab Pub Date : 2024-08-01 DOI:10.1016/j.jmsacl.2024.08.003
{"title":"利用质谱法快速鉴定 SARS CoV-2 omicron 亚变体 JN.1 (BA.2.86.1.1)","authors":"","doi":"10.1016/j.jmsacl.2024.08.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>The rapid detection and differentiation of strains of the BA.2.86 lineage including the new sub-variant JN.1 (BA.2.86.1.1) is demonstrated employing selected ion monitoring (SIM) and high resolution mass spectrometry.</p></div><div><h3>Methods</h3><p>A study of a preliminary set of BA.2.86 lineage positive specimens, identified BA.2.86 and BA.2.86.1.1 peptide markers in 62.5 % and 29.1 % of samples.</p></div><div><h3>Results</h3><p>Peptide-specific markers in the surface spike protein associated with the L455S mutation are confidently detected with high sensitivity in protein and virus digests.</p><p>The virus was thus confidently assigned in over 91 % of positive specimens.</p></div><div><h3>Conclusions</h3><p>A rise in the global prevalence of the JN.1 (BA.2.86.1.1) immune evasive sub-variant, that emerged in late 2023, requires that new strategies and protocols to detect such strains in human specimens are accelerated and implemented.</p></div>","PeriodicalId":52406,"journal":{"name":"Journal of Mass Spectrometry and Advances in the Clinical Lab","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2667145X24000294/pdfft?md5=1ccf05ce3d97520e6ac37ad4c6ea2d3e&pid=1-s2.0-S2667145X24000294-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Rapid identification of SARS CoV-2 omicron sub-variant JN.1 (BA.2.86.1.1) with mass spectrometry\",\"authors\":\"\",\"doi\":\"10.1016/j.jmsacl.2024.08.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>The rapid detection and differentiation of strains of the BA.2.86 lineage including the new sub-variant JN.1 (BA.2.86.1.1) is demonstrated employing selected ion monitoring (SIM) and high resolution mass spectrometry.</p></div><div><h3>Methods</h3><p>A study of a preliminary set of BA.2.86 lineage positive specimens, identified BA.2.86 and BA.2.86.1.1 peptide markers in 62.5 % and 29.1 % of samples.</p></div><div><h3>Results</h3><p>Peptide-specific markers in the surface spike protein associated with the L455S mutation are confidently detected with high sensitivity in protein and virus digests.</p><p>The virus was thus confidently assigned in over 91 % of positive specimens.</p></div><div><h3>Conclusions</h3><p>A rise in the global prevalence of the JN.1 (BA.2.86.1.1) immune evasive sub-variant, that emerged in late 2023, requires that new strategies and protocols to detect such strains in human specimens are accelerated and implemented.</p></div>\",\"PeriodicalId\":52406,\"journal\":{\"name\":\"Journal of Mass Spectrometry and Advances in the Clinical Lab\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2667145X24000294/pdfft?md5=1ccf05ce3d97520e6ac37ad4c6ea2d3e&pid=1-s2.0-S2667145X24000294-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mass Spectrometry and Advances in the Clinical Lab\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2667145X24000294\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mass Spectrometry and Advances in the Clinical Lab","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667145X24000294","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的 利用选择离子监测(SIM)和高分辨质谱法证明了对 BA.2.86 系菌株(包括新的亚变异株 JN.1(BA.2.86.1.1))的快速检测和区分。结果与 L455S 突变相关的表面尖峰蛋白中的肽特异性标记在蛋白质和病毒消化液中被高灵敏度地检测到。(结论 2023 年末,JN.1(BA.2.86.1.1)免疫逃避亚变异株在全球的流行率上升,这要求加快并实施在人类样本中检测此类毒株的新策略和方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Rapid identification of SARS CoV-2 omicron sub-variant JN.1 (BA.2.86.1.1) with mass spectrometry

Objective

The rapid detection and differentiation of strains of the BA.2.86 lineage including the new sub-variant JN.1 (BA.2.86.1.1) is demonstrated employing selected ion monitoring (SIM) and high resolution mass spectrometry.

Methods

A study of a preliminary set of BA.2.86 lineage positive specimens, identified BA.2.86 and BA.2.86.1.1 peptide markers in 62.5 % and 29.1 % of samples.

Results

Peptide-specific markers in the surface spike protein associated with the L455S mutation are confidently detected with high sensitivity in protein and virus digests.

The virus was thus confidently assigned in over 91 % of positive specimens.

Conclusions

A rise in the global prevalence of the JN.1 (BA.2.86.1.1) immune evasive sub-variant, that emerged in late 2023, requires that new strategies and protocols to detect such strains in human specimens are accelerated and implemented.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Mass Spectrometry and Advances in the Clinical Lab
Journal of Mass Spectrometry and Advances in the Clinical Lab Health Professions-Medical Laboratory Technology
CiteScore
4.30
自引率
18.20%
发文量
41
审稿时长
81 days
期刊最新文献
Impact of internal standard selection on measurement results for long chain fatty acids in blood Comparison between a single- and a multi-point calibration method using LC-MS/MS for measurement of 5-fluorouracil in human plasma Rapid identification of SARS CoV-2 omicron sub-variant JN.1 (BA.2.86.1.1) with mass spectrometry Isotope-dilution-LC-MS/MS candidate reference measurement procedure for cefepime in human serum Understanding isotopes, isomers, and isobars in mass spectrometry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1