使用胸带和干电极系统进行长期心律失常监测的可行性:试点观察研究的结果。

{"title":"使用胸带和干电极系统进行长期心律失常监测的可行性:试点观察研究的结果。","authors":"","doi":"10.1016/j.ipej.2024.08.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and aim</h3><div>Cardiac arrhythmia diagnostic yield improves with increased duration of monitoring. We investigated patient comfort, diagnostic quality of ECG, and arrhythmia diagnostic yield using a single lead longer term external cardiac monitor (ECM).</div></div><div><h3>Methods</h3><div>The observational ECM feasibility study enrolled patients with increased risk of cardiac arrhythmia. The ECM investigational prototype was designed using a chest strap with dry electrodes connected to module capable of triggered loop recording of ECG, and automatic detection of arrhythmia. In group-A of study (24-h inpatient), patients wore ECM and Holter that recorded ECG from the ECM and adhesive electrodes. In group-B of study (12-weeks ambulatory), at monthly follow-ups patients filled out a comfort survey and device stored arrhythmia episodes were reviewed.</div></div><div><h3>Results</h3><div>The study enrolled 34 patients (38 % females, average age 57.5 years, 65 % had palpitations, 12 % had syncope). Diagnostic quality ECG was recorded on 76.5 % of the monitoring duration in 12 of 20 patients with reviewable data in group-A, with motion artifacts causing loss in ECG signal for 18.7 % of the time. In 14 patients in group-B, 94.9 % of the survey responses indicated that ECM was comfortable to wear. Cardiac arrhythmia was observed in 4 of 17 patients (24 %) in group-A and 9 of 14 patients (64 %) in group-B in device recorded episodes. All ECM detected pause and tachycardia were inappropriate detections due to motion artifacts and temporary device removal.</div></div><div><h3>Conclusion</h3><div>The chest strap-based ECM device was mostly comfortable to wear and recorded diagnostic quality ECG in three-fourth of monitoring period. Cardiac arrhythmia was observed in 64 % of patients over 3-month monitoring along with large number of motion artifact induced inappropriate detections.</div></div>","PeriodicalId":35900,"journal":{"name":"Indian Pacing and Electrophysiology Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Feasibility of using chest strap and dry electrode system for longer term cardiac arrhythmia monitoring: Results from a pilot observational study\",\"authors\":\"\",\"doi\":\"10.1016/j.ipej.2024.08.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background and aim</h3><div>Cardiac arrhythmia diagnostic yield improves with increased duration of monitoring. We investigated patient comfort, diagnostic quality of ECG, and arrhythmia diagnostic yield using a single lead longer term external cardiac monitor (ECM).</div></div><div><h3>Methods</h3><div>The observational ECM feasibility study enrolled patients with increased risk of cardiac arrhythmia. The ECM investigational prototype was designed using a chest strap with dry electrodes connected to module capable of triggered loop recording of ECG, and automatic detection of arrhythmia. In group-A of study (24-h inpatient), patients wore ECM and Holter that recorded ECG from the ECM and adhesive electrodes. In group-B of study (12-weeks ambulatory), at monthly follow-ups patients filled out a comfort survey and device stored arrhythmia episodes were reviewed.</div></div><div><h3>Results</h3><div>The study enrolled 34 patients (38 % females, average age 57.5 years, 65 % had palpitations, 12 % had syncope). Diagnostic quality ECG was recorded on 76.5 % of the monitoring duration in 12 of 20 patients with reviewable data in group-A, with motion artifacts causing loss in ECG signal for 18.7 % of the time. In 14 patients in group-B, 94.9 % of the survey responses indicated that ECM was comfortable to wear. Cardiac arrhythmia was observed in 4 of 17 patients (24 %) in group-A and 9 of 14 patients (64 %) in group-B in device recorded episodes. All ECM detected pause and tachycardia were inappropriate detections due to motion artifacts and temporary device removal.</div></div><div><h3>Conclusion</h3><div>The chest strap-based ECM device was mostly comfortable to wear and recorded diagnostic quality ECG in three-fourth of monitoring period. Cardiac arrhythmia was observed in 64 % of patients over 3-month monitoring along with large number of motion artifact induced inappropriate detections.</div></div>\",\"PeriodicalId\":35900,\"journal\":{\"name\":\"Indian Pacing and Electrophysiology Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Pacing and Electrophysiology Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S097262922400113X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Pacing and Electrophysiology Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S097262922400113X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:心律失常诊断率随着监护时间的延长而提高。我们研究了使用单导联长期体外心脏监护仪(ECM)的患者舒适度、心电图诊断质量和心律失常诊断率:观察性 ECM 可行性研究招募了心律失常风险较高的患者。ECM 的研究原型设计使用胸带,胸带上的干电极与模块相连,能够触发循环记录心电图并自动检测心律失常。在研究的 A 组(24 小时住院患者)中,患者佩戴 ECM 和 Holter,通过 ECM 和粘性电极记录心电图。在研究 B 组(12 周非卧床)中,患者在每月随访时填写舒适度调查表,并对设备存储的心律失常事件进行复查:研究共招募了 34 名患者(38% 为女性,平均年龄 57.5 岁,65% 有心悸症状,12% 有晕厥症状)。在 20 名患者中,A 组有 12 人在 76.5%的监测时间内记录到了高质量的心电图,其中 18.7%的时间因运动伪影导致心电图信号丢失。在 B 组的 14 名患者中,94.9% 的受访者表示 ECM 佩戴舒适。在设备记录的事件中,A 组 17 名患者中有 4 人(24%)观察到心律失常,B 组 14 名患者中有 9 人(64%)观察到心律失常。所有 ECM 检测到的暂停和心动过速都是由于运动伪影和临时移除设备造成的不恰当检测:结论:胸带式 ECM 设备佩戴舒适,在四分之三的监测时间内记录到诊断质量的心电图。临床试验注册:临床试验注册号:CTRI/2020/02/023576。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Feasibility of using chest strap and dry electrode system for longer term cardiac arrhythmia monitoring: Results from a pilot observational study

Background and aim

Cardiac arrhythmia diagnostic yield improves with increased duration of monitoring. We investigated patient comfort, diagnostic quality of ECG, and arrhythmia diagnostic yield using a single lead longer term external cardiac monitor (ECM).

Methods

The observational ECM feasibility study enrolled patients with increased risk of cardiac arrhythmia. The ECM investigational prototype was designed using a chest strap with dry electrodes connected to module capable of triggered loop recording of ECG, and automatic detection of arrhythmia. In group-A of study (24-h inpatient), patients wore ECM and Holter that recorded ECG from the ECM and adhesive electrodes. In group-B of study (12-weeks ambulatory), at monthly follow-ups patients filled out a comfort survey and device stored arrhythmia episodes were reviewed.

Results

The study enrolled 34 patients (38 % females, average age 57.5 years, 65 % had palpitations, 12 % had syncope). Diagnostic quality ECG was recorded on 76.5 % of the monitoring duration in 12 of 20 patients with reviewable data in group-A, with motion artifacts causing loss in ECG signal for 18.7 % of the time. In 14 patients in group-B, 94.9 % of the survey responses indicated that ECM was comfortable to wear. Cardiac arrhythmia was observed in 4 of 17 patients (24 %) in group-A and 9 of 14 patients (64 %) in group-B in device recorded episodes. All ECM detected pause and tachycardia were inappropriate detections due to motion artifacts and temporary device removal.

Conclusion

The chest strap-based ECM device was mostly comfortable to wear and recorded diagnostic quality ECG in three-fourth of monitoring period. Cardiac arrhythmia was observed in 64 % of patients over 3-month monitoring along with large number of motion artifact induced inappropriate detections.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Pacing and Electrophysiology Journal
Indian Pacing and Electrophysiology Journal Medicine-Cardiology and Cardiovascular Medicine
CiteScore
2.20
自引率
0.00%
发文量
91
审稿时长
61 days
期刊介绍: Indian Pacing and Electrophysiology Journal is a peer reviewed online journal devoted to cardiac pacing and electrophysiology. Editorial Advisory Board includes eminent personalities in the field of cardiac pacing and electrophysiology from Asia, Australia, Europe and North America.
期刊最新文献
Atrial leadless pacemaker implant using Aveir VR in an Adolescent with congenital heart disease. Feasibility of a using chest strap and dry electrode system for longer term cardiac arrhythmia monitoring: Correspondence. Two distinct stages and mechanisms of ST-elevation during cryothermal cavotricuspid isthmus ablation guided by intracardiac echocardiography: A case report. Pivoting turn-around activation guided successful slow pathway ablation in the cavotricuspid isthmus. Late onset of two concurrent and dissociated arrhythmias in a transplanted heart.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1