超级微血管成像在慢性肾脏病肾皮质厚度测量中的附加值。

IF 1.2 4区 医学 Q3 ACOUSTICS Journal of Clinical Ultrasound Pub Date : 2024-11-01 Epub Date: 2024-08-27 DOI:10.1002/jcu.23796
Poemporn Limpisook, Pooriput Waongenngarm, Surachate Siripongsakun, Nannapat Nuangchamnong, Nutsurang Promrach, Thananya Thabsangthong
{"title":"超级微血管成像在慢性肾脏病肾皮质厚度测量中的附加值。","authors":"Poemporn Limpisook, Pooriput Waongenngarm, Surachate Siripongsakun, Nannapat Nuangchamnong, Nutsurang Promrach, Thananya Thabsangthong","doi":"10.1002/jcu.23796","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to evaluate renal parenchymal thickness and renal cortical thickness measurements on brightness mode ultrasound (B-mode US) and B-mode US + Superb Microvascular Imaging (SMI) technique, comparing with computed tomography (CT) or magnetic resonance imaging (MRI) serving as a reference standard.</p><p><strong>Methods: </strong>Renal parenchymal thickness and renal cortical thickness measurements were obtained from B-mode US, B-mode US + SMI, and CT/MRI in a group of healthy subjects and a group of patients with chronic kidney disease (CKD). The mean differences and correlations of renal parenchymal thickness and renal cortical thickness were analyzed using dependent pair t-test and Pearson's correlation, respectively.</p><p><strong>Results: </strong>The mean difference in renal cortical thickness measurements between B-mode US + SMI and CT/MRI was lower than the mean difference between B-mode US alone and CT/MRI. Additionally, renal cortical thickness measured using B-mode US + SMI showed a stronger correlation with values obtained from CT/MRI than values measured using standard B-mode US alone.</p><p><strong>Conclusion: </strong>The measurement of renal cortical thickness by B-mode US + SMI is more accurate than that by B-mode US alone.</p>","PeriodicalId":15386,"journal":{"name":"Journal of Clinical Ultrasound","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The added value of superb microvascular imaging for renal cortical thickness measurement in chronic kidney disease.\",\"authors\":\"Poemporn Limpisook, Pooriput Waongenngarm, Surachate Siripongsakun, Nannapat Nuangchamnong, Nutsurang Promrach, Thananya Thabsangthong\",\"doi\":\"10.1002/jcu.23796\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this study was to evaluate renal parenchymal thickness and renal cortical thickness measurements on brightness mode ultrasound (B-mode US) and B-mode US + Superb Microvascular Imaging (SMI) technique, comparing with computed tomography (CT) or magnetic resonance imaging (MRI) serving as a reference standard.</p><p><strong>Methods: </strong>Renal parenchymal thickness and renal cortical thickness measurements were obtained from B-mode US, B-mode US + SMI, and CT/MRI in a group of healthy subjects and a group of patients with chronic kidney disease (CKD). The mean differences and correlations of renal parenchymal thickness and renal cortical thickness were analyzed using dependent pair t-test and Pearson's correlation, respectively.</p><p><strong>Results: </strong>The mean difference in renal cortical thickness measurements between B-mode US + SMI and CT/MRI was lower than the mean difference between B-mode US alone and CT/MRI. Additionally, renal cortical thickness measured using B-mode US + SMI showed a stronger correlation with values obtained from CT/MRI than values measured using standard B-mode US alone.</p><p><strong>Conclusion: </strong>The measurement of renal cortical thickness by B-mode US + SMI is more accurate than that by B-mode US alone.</p>\",\"PeriodicalId\":15386,\"journal\":{\"name\":\"Journal of Clinical Ultrasound\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Ultrasound\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/jcu.23796\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jcu.23796","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在评估亮度模式超声(B-mode US)和B-mode US + 超微血管成像(SMI)技术的肾实质厚度和肾皮质厚度测量结果,并与作为参考标准的计算机断层扫描(CT)或磁共振成像(MRI)进行比较:方法:通过 B 型 US、B 型 US + SMI 和 CT/MRI 测量一组健康受试者和一组慢性肾脏病(CKD)患者的肾实质厚度和肾皮质厚度。结果显示,肾实质厚度和肾皮质厚度的平均差异和相关性分别采用因果配对 t 检验和皮尔逊相关分析:结果:B型超声+SMI与CT/MRI的肾皮质厚度测量值的平均差异低于单独B型超声与CT/MRI的平均差异。此外,与单独使用标准 B 型 US 测量值相比,使用 B 型 US + SMI 测量的肾皮质厚度与 CT/MRI 测量值的相关性更强:结论:使用 B 型 US + SMI 测量肾皮质厚度比单独使用 B 型 US 测量更准确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The added value of superb microvascular imaging for renal cortical thickness measurement in chronic kidney disease.

Purpose: The aim of this study was to evaluate renal parenchymal thickness and renal cortical thickness measurements on brightness mode ultrasound (B-mode US) and B-mode US + Superb Microvascular Imaging (SMI) technique, comparing with computed tomography (CT) or magnetic resonance imaging (MRI) serving as a reference standard.

Methods: Renal parenchymal thickness and renal cortical thickness measurements were obtained from B-mode US, B-mode US + SMI, and CT/MRI in a group of healthy subjects and a group of patients with chronic kidney disease (CKD). The mean differences and correlations of renal parenchymal thickness and renal cortical thickness were analyzed using dependent pair t-test and Pearson's correlation, respectively.

Results: The mean difference in renal cortical thickness measurements between B-mode US + SMI and CT/MRI was lower than the mean difference between B-mode US alone and CT/MRI. Additionally, renal cortical thickness measured using B-mode US + SMI showed a stronger correlation with values obtained from CT/MRI than values measured using standard B-mode US alone.

Conclusion: The measurement of renal cortical thickness by B-mode US + SMI is more accurate than that by B-mode US alone.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
248
审稿时长
6 months
期刊介绍: The Journal of Clinical Ultrasound (JCU) is an international journal dedicated to the worldwide dissemination of scientific information on diagnostic and therapeutic applications of medical sonography. The scope of the journal includes--but is not limited to--the following areas: sonography of the gastrointestinal tract, genitourinary tract, vascular system, nervous system, head and neck, chest, breast, musculoskeletal system, and other superficial structures; Doppler applications; obstetric and pediatric applications; and interventional sonography. Studies comparing sonography with other imaging modalities are encouraged, as are studies evaluating the economic impact of sonography. Also within the journal''s scope are innovations and improvements in instrumentation and examination techniques and the use of contrast agents. JCU publishes original research articles, case reports, pictorial essays, technical notes, and letters to the editor. The journal is also dedicated to being an educational resource for its readers, through the publication of review articles and various scientific contributions from members of the editorial board and other world-renowned experts in sonography.
期刊最新文献
Sonography Could Predict Complete/Near-Complete Necrosis of Thyroid Tumors After Fine-Needle Biopsy: Necrotic Ring Sign. Fetal Face: Enhancing Three Dimensional Ultrasound Imaging by Postprocessing With Artificial Intelligence Applications: Correspondence. Posterior Fossa Anomalies: From Diagnosis to the Challenges of Counseling Regarding Prognosis. Superb Microvascular Imaging Is Better Than Power Doppler Ultrasound in Diagnosing Subclinical Synovitis in Patients With Inflammatory Arthritis in Remission. Prevalence of Chronic Liver Disease Based on Ultrasound Shear Wave Elastography in an Adult Asian Indian Population Attending Outpatient Preventive Radiology Clinics in India.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1