用于血管内超声成像的基于 Sm 掺杂 Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 陶瓷的高频超声换能器

IF 2.5 4区 医学 Q1 ACOUSTICS Ultrasonic Imaging Pub Date : 2024-11-01 Epub Date: 2024-08-27 DOI:10.1177/01617346241271119
Ding Weiyan, Xingfei Chen, Yongcheng Zhang, Xiaobing Li, Fenglong Sun, Zhaoping Yang, Xi Tang, Changjiang Zhou, Feifei Wang, Xiangyong Zhao
{"title":"用于血管内超声成像的基于 Sm 掺杂 Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 陶瓷的高频超声换能器","authors":"Ding Weiyan, Xingfei Chen, Yongcheng Zhang, Xiaobing Li, Fenglong Sun, Zhaoping Yang, Xi Tang, Changjiang Zhou, Feifei Wang, Xiangyong Zhao","doi":"10.1177/01617346241271119","DOIUrl":null,"url":null,"abstract":"<p><p>Sm-doped Pb(Mg<sub>1/3</sub>Nb<sub>2/3</sub>)O<sub>3</sub>-0.28PbTiO<sub>3</sub> (PMN-0.28PT) ceramic has been reported to exhibit very large piezoelectric response (<i>d</i><sub>33</sub>~1300 pC/N) that can be comparable with PMN-0.30PT single crystal. Based on the Sm-doped PMN-0.28PT ceramics, a high frequency ultrasound transducer with the center frequency above 30 MHz has been designed and fabricated for intravascular ultrasound imaging, and the performance of the transducer was investigated via ultrasound pulse-echo tests. Further, for a porcine vessel wall, the 2D and 3D ultrasound images were constructed using signal acquisition and processing from the fabricated high-frequency transducer. The obtained details of the vessel wall by the IVUS transducer indicate that Sm-doped PMN-0.28PT ceramic is a promising candidate for high frequency transducers.</p>","PeriodicalId":49401,"journal":{"name":"Ultrasonic Imaging","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High Frequency Ultrasound Transducer Based on Sm-Doped Pb(Mg<sub>1/3</sub>Nb<sub>2/3</sub>)O<sub>3</sub>-0.28PbTiO<sub>3</sub> Ceramic for Intravascular Ultrasound Imaging.\",\"authors\":\"Ding Weiyan, Xingfei Chen, Yongcheng Zhang, Xiaobing Li, Fenglong Sun, Zhaoping Yang, Xi Tang, Changjiang Zhou, Feifei Wang, Xiangyong Zhao\",\"doi\":\"10.1177/01617346241271119\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Sm-doped Pb(Mg<sub>1/3</sub>Nb<sub>2/3</sub>)O<sub>3</sub>-0.28PbTiO<sub>3</sub> (PMN-0.28PT) ceramic has been reported to exhibit very large piezoelectric response (<i>d</i><sub>33</sub>~1300 pC/N) that can be comparable with PMN-0.30PT single crystal. Based on the Sm-doped PMN-0.28PT ceramics, a high frequency ultrasound transducer with the center frequency above 30 MHz has been designed and fabricated for intravascular ultrasound imaging, and the performance of the transducer was investigated via ultrasound pulse-echo tests. Further, for a porcine vessel wall, the 2D and 3D ultrasound images were constructed using signal acquisition and processing from the fabricated high-frequency transducer. The obtained details of the vessel wall by the IVUS transducer indicate that Sm-doped PMN-0.28PT ceramic is a promising candidate for high frequency transducers.</p>\",\"PeriodicalId\":49401,\"journal\":{\"name\":\"Ultrasonic Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasonic Imaging\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/01617346241271119\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonic Imaging","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/01617346241271119","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/27 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

据报道,掺钐的 Pb(Mg1/3Nb2/3)O3-0.28PbTiO3(PMN-0.28PT)陶瓷表现出非常大的压电响应(d33~1300 pC/N),可与 PMN-0.30PT 单晶相媲美。基于掺杂 Sm 的 PMN-0.28PT 陶瓷,设计和制造了一种中心频率高于 30 MHz 的高频超声换能器,用于血管内超声成像,并通过超声脉冲回波测试研究了换能器的性能。此外,还利用所制造的高频换能器进行信号采集和处理,构建了猪血管壁的二维和三维超声图像。通过 IVUS 换能器获得的血管壁细节表明,掺杂 Sm 的 PMN-0.28PT 陶瓷有望成为高频换能器的候选材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High Frequency Ultrasound Transducer Based on Sm-Doped Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 Ceramic for Intravascular Ultrasound Imaging.

Sm-doped Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 (PMN-0.28PT) ceramic has been reported to exhibit very large piezoelectric response (d33~1300 pC/N) that can be comparable with PMN-0.30PT single crystal. Based on the Sm-doped PMN-0.28PT ceramics, a high frequency ultrasound transducer with the center frequency above 30 MHz has been designed and fabricated for intravascular ultrasound imaging, and the performance of the transducer was investigated via ultrasound pulse-echo tests. Further, for a porcine vessel wall, the 2D and 3D ultrasound images were constructed using signal acquisition and processing from the fabricated high-frequency transducer. The obtained details of the vessel wall by the IVUS transducer indicate that Sm-doped PMN-0.28PT ceramic is a promising candidate for high frequency transducers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultrasonic Imaging
Ultrasonic Imaging 医学-工程:生物医学
CiteScore
5.10
自引率
8.70%
发文量
15
审稿时长
>12 weeks
期刊介绍: Ultrasonic Imaging provides rapid publication for original and exceptional papers concerned with the development and application of ultrasonic-imaging technology. Ultrasonic Imaging publishes articles in the following areas: theoretical and experimental aspects of advanced methods and instrumentation for imaging
期刊最新文献
Image Features and Diagnostic Value of Contrast-Enhanced Ultrasound for Ductal Carcinoma In Situ of the Breast: Preliminary Findings. Ultrasonic Imaging of Deeper Bone Defect Using Virtual Source Synthetic Aperture with Phased Shift Migration: A Phantom Study. Predictive Value of the Nomogram Model Based on Multimodal Ultrasound Features for Benign and Malignant Thyroid Nodules of C-TIRADS Category 4. High Frequency Ultrasound Transducer Based on Sm-Doped Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 Ceramic for Intravascular Ultrasound Imaging. Development and Assessment of a Predictive Model for Ki-67 Expression Using Ultrasound Indicators and Non-Morphological Magnetic Resonance Imaging Parameters Before Breast Cancer Therapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1